Daikin AHQ140CV1 [23/52] Foutdiagnose

Daikin AHQ140CV1 [23/52] Foutdiagnose
15
NEDERLANDS
SWING
TURBO
QUIET
SLEEP
ON
CANCEL
CANCEL
OFF
TIMER
CLOCK
MODE
FAN
FOUTDIAGNOSE (Alleen voor Inverter)
FOUTCODE BETEKENIS
00 NORMAAL
A1 PCB-FOUT BINNENSHUIS
A3 AFVOERPOMP ABNORMAAL
A5 ANTIVRIES (KOELING)/WARMTEWISSELAAR OVERVERHIT (VERWARMING)
A6 VENTILATORMOTOR BINNENSHUIS ABNORMAAL
AH ELEKTRISCHE LUCHTREINIGER ABNORMAAL
C4 WARMTEWISSELAAR BINNENSHUIS (1) THERMISTOR KORTSLUITING/OPEN
C5 WARMTEWISSELAAR BINNENSHUIS (2) THERMISTOR KORTSLUITING/OPEN
C7 FOUT SCHAKELAAR UITERSTE STAND LAMELLEN
C9 THERMISTOR KAMER BINNENSHUIS KORTSLUITING/OPEN
E1 PCB-FOUT BUITENSHUIS
E3 HOGEDRUKBEVEILIGING
E4 LAGEDRUKBEVEILIGING
E5 VERGRENDELING COMPRESSORMOTOR/COMPRESSOR OVERBELAST
E6 OPSTARTFOUT COMPRESSOR
E7 VERGRENDELING GELIJKSTROOMMOTOR VENTILATIE BUITENSHUIS
E8 TE HOGE STROOMSTERKTE WISSELSTROOM
E9 EXV-FOUT
EA FOUT 4-WEG-KLEP
F3 OVERVERHITTING AFVOERLEIDING
F6 OVERVERHITTING WARMTEWISSELAAR
HO FOUT COMPRESSOR-SENSORSYSTEEM
H3 FOUT HOGEDRUKSCHAKELAAR
H6 FOUT COMPRESSOR-TERUGKOPPELINGSDETECTIE
H7 VENTILATORMOTOR OVERBELAST/TE HOGE STROOMSTERKTE/SENSOR ABNORMAAL
H8 FOUT WISSELSTROOMSENSOR
FOUTDIAGNOSE DOOR MIDDEL VAN AFSTANDSBEDIENING
De gedeelten voor temperatuurweergave geven de bijbehorende codes aan.
Wanneer u de toets AAN-TIMER ANNULEREN of UIT-TIMER ANNULEREN 5 seconden ingedrukt
houdt, knippert een aanduiding "
0000
" op het gedeelte voor de temperatuurweergave.
1.
AAN-TIMER ANNULEREN
UIT-TIMER ANNULEREN
Druk herhaaldelijk op de toets AAN-TIMER ANNULEREN of UIT-TIMER ANNULEREN totdat
er een ononderbroken akoestisch signaal klinkt.
De codeaanduiding wijzigt zoals hieronder wordt getoond en wordt bevestigd met een lang
akoestisch signaal.
2.
04-NL-OM-GS02-0411(0)-Siesta.ind15 1504-NL-OM-GS02-0411(0)-Siesta.ind15 15 5/24/11 3:32:08 PM5/24/11 3:32:08 PM