Daikin EKEQFCBV3 [12/17] Ekeqdcb

Daikin EKEQMCBAV3 [12/17] Ekeqdcb
Accessory • EKEQ
7
Ventilation • EKEQ
10
7 Wiring diagrams
7 - 1 Wiring Diagrams - Single Phase
2TW32146-1
EKEQDCB
A1P : Printed circuit board
A2P : Printed circuit board (Option KRP4)
F1U : Fuse (250V, F5A) (A1P)
F3U : Field fuse
HAP : Light emitting diode (service monitor green)
K1R : Magnetic relay
K4R : Magnetic relay (Fan) AC
Q1DI : Earth leakage breaker
R7 : Capacity adaptor
R1T : Thermistor (Air)
R2T : Thermistor (Liquid)
R3T : Thermistor (Gas)
T1R : Transformer (220V/21.8V)
X1M : Terminal block
X3M : Terminal block
X1M-R1/R2 : Thermistor Liquid
X1M-R3/R4 : Thermistor Gas
X1M-R5/R6 : Thermistor Air
X1M-Y16 : Expansion valve
X1M-C1/C2 : Output: Fan ON/OFF
X1M-P1/P2 : Communication remote controller
X1M-F1/F2 : Communication outdoor
X1M-T1/T2 : Input: ON/OFF
Y1E : Electronic expansion valve
: Live
: Neutral
: Connector
: Wire clamp
: Protective earth (Screw)
: Seperate component
: Optional accessory
: Field wiring
Wired remote control
Outdoor
1 Use copper conductors only.
2 BLK: Black / WHT: White / RED: Red / BLU: Blue /
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange /
PINK: Pink / YLW: Yellow
Position in switch box
2TW32136-1
EKEQFCB
A1P : Printed circuit board
A2P : Printed circuit board (for voltage conversion)
A3P : Printed circuit board (Power supply)
F1U : Fuse (250V, F5A) (A1P)
F2U : Fuse (250V, T1A) (A3P)
F3U : Field fuse
HAP : Light emitting diode (service monitor green)
K2R : Magnetic relay (error status) AC
K3R : Magnetic relay (Operation / Compressor ON/OFF) AC
K4R : Magnetic relay (Fan) AC
K5R : Magnetic relay (Defrost signal) DC
K1R, KAR, KPR : Magnetic relay
Q1DI : Earth leakage breaker
R5 : Resistance (DC 120 OHM)
R6 : Capacity adaptor
R2T : Thermistor (Liquid)
R3T : Thermistor (Gas)
T1R : Transformer (220V/21.8V)
X1M : Terminal block
X2M : Terminal block
X3M : Terminal block
Y1E : Electronic expansion valve
X1M-R1/R2 : Thermistor Liquid
X1M-R3/R4 : Thermistor Gas
X1M-Y16 : Expansion valve
X2M-P1/P2 : Communication remote controller
X2M-C1/C2 : Output: error status
X2M-C3/C4 : Output: Operation / Compressor ON/OFF
X2M-C5/C6 : Input: 0-10V DC capacity control
X1M-C7/C8 : Output: Fan ON/OFF
X1M-C9/C10 : Output: Defrost signal
X2M-F1/F2 : Communication outdoor
X2M-T1/T2 : Input: ON/OFF
: Live
: Neutral
: Connector
: Wire clamp
: Protective earth (Screw)
: Seperate component
: Optional accessory
: Field wiring
Wired remote control
Outdoor
Only for 0-10V input
1 Use copper conductors only.
2 BLK: Black / WHT: White / RED: Red / BLU: Blue /
BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange /
PINK: Pink / YLW: Yellow
Position in switch box