Troubleshooting SiBE12-908_A
107 Service Diagnosis
2. Troubleshooting
2.1 Error Code Indication by Remote Controller
* Various cases may be possible.
Code Unit Description Reference page
Basic Failure Diagnosis
Air conditioner does not run. 109
Air conditioner runs but does not get cooling (heating). 112
When operation starts, safety breaker works. 114
Air conditioner makes big noise and vibration. 116
Air does not humidified enough. 117
A1
Indoor
Indoor unit PCB abnormality 120
A5
Freeze-up protection or heating peak-cut control 121
A6
Fan motor or related abnormality 123
C4
Indoor heat exchanger thermistor abnormality 125
C9
Room temperature thermistor abnormality 125
CC
Humidity sensor abnormality 126
E1
Outdoor
Outdoor unit PCB abnormality 132
E5
OL activation (compressor overload) 133
E6
Compressor lock 134
E7
DC fan lock 135
E8
Input overcurrent detection 136
F3
Discharge pipe temperature control 138
F6
High pressure control in cooling 139
H0
Compressor sensor system abnormality 141
H1
Humidifying unit Damper abnormality 142
H6
Outdoor
Position sensor abnormality 143
H8
DC voltage / DC current sensor abnormality 145
H9
Outdoor air thermistor abnormality 146
J3
Discharge pipe thermistor abnormality 146
J6
Outdoor heat exchanger thermistor abnormality 146
J8
Liquid pipe thermistor abnormality 146
J9
Gas pipe thermistor abnormality 146
L3
Abnormal temperature in electrical box 148
L4
Temperature rise in radiation fin 150
L5
Output overcurrent 152
P4
Radiation fin thermistor abnormality 146
P9
Humidifying unit
Fan motor system abnormality / fan lock 162
PA
Heater wire abnormality 163
PH
Humidification fan outlet thermistor abnormality / abnormal heater
temperature
165
U0
System
Refrigerant shortage 154
U2
Over voltage protection (OVP) / low voltage protection (LVP) 156
U4
Signal transmission error (indoor unit - outdoor unit) 127
Outdoor Outdoor unit PCB abnormality or communication circuit abnormality 157
U7
System
Signal transmission error on outdoor unit PCB 160
UA
Incompatible power supply between indoor unit and outdoor unit 129
Indoor Incomplete setting for hose length 130