Daikin FH50BVE [7/16] And display on the remote controller
![Daikin FH35BVE [7/16] And display on the remote controller](/views2/1764313/page7/bg7.png)
English 4
D
B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.
Regarding places for installation
•
Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Do not use the air conditioner in the following
places.
a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring
resort
d.Where there are considerable voltage fluctua-
tions such as a factory or plant
e.Vehicles and vessels
f
.Where there is much spray of oil and vapor such
as a cookery, etc.
g.Where there are machines generating electro-
magnetic waves
h.Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by your-
self.
• Make sure that a separate power supply cir-
cuit is provided for this air conditioner and
that all electrical work is carried out by quali-
fied personnel according to local laws and
regulations.
Pay attention to running noises, too
• Are the following places selected?
a.A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b.A place where the hot wind discharged from the
air outlet of the outdoor unit and the running
noises.
• Are you sure that there are no obstacles near
the air outlet of the outdoor unit?
Such obstacles may result in declined perfor-
mance and increased running noises.
• If abnormal noises occur in use, consult your
dealer.
4. INSTALLATION SITE
Regarding drainage of drain piping
• Is the drain piping executed to perform com-
plete drainage?
If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation,
chances are that dust and dirt are clogged in the
pipe. This may result in a water leakage from the
indoor unit. Under such circumstances, stop the
operation of the air conditioner, and then consult
your dealer or our service station.
Refer to figure 1 on page [1]
The illustrations in this operating manual corre-
spond to the remote control format BRC1C type.
Although the display and shape of the buttons on
the BRC1B type are slightly different, they may be
operated in the same manner.
5.
NAME AND FUNCTION OF EACH
SWITCH
AND DISPLAY ON THE
REMOTE CONTROLLER
1
ON/OFF BUTTON
Press the button and the system will start.
Press the button again and the system will
stop.
2
OPERATION LAMP (RED)
The lamp lights up during operation.
3
DISPLAY “ ” (UNDER CENTRAL-
IZED CONTROL)
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
4
DISPLAY “ ” “ ” “ ” “ ”
(VENTILATION/AIR CLEANING)
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional accessories).
5
DISPLAY “ ” “ ” “ ” “ ” “ ”
(OPERATION MODE)
This display shows the current OPERATION
MODE. For cooling only type, “ ” (Auto)
and “ ” (Heating) are not installed.
6
DISPLAY “
TEST
” (INSPECTION/TEST
OPERATION)
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
7
DISPLAY “ ” (PROGRAMMED TIME)
This display shows the PROGRAMMED TIME
of the system start or stop.
hr
hr
01_EN_3P170549-4.fm Page 4 Friday, December 9, 2005 11:49 AM
Содержание
- Operation manual 1
- Split system air conditioner 1
- 16 17 18 3
- Contents 4
- Indoor unit 4
- Names and functions of parts 4
- Outdoor unit 4
- Precautions for group control system or two remote controller control system 4
- Unit with remote controller 4
- Unit without remote controller when used as simultaneous operation system 4
- What to do before opera tion 4
- What to do before operation 4
- Safety considerations 5
- Operation range 6
- And display on the remote controller 7
- Installation site 7
- Name and function of each switc 7
- Name and function of each switch and display on the remote controller 7
- Pay attention to running noises too 7
- Regarding drainage of drain piping 7
- Regarding places for installation 7
- Regarding wiring 7
- Cooling heating automatic fan and program dry operation 8
- Inspection test operation button 8
- On off 8
- Operation mode selec tor 8
- Operation procedure 8
- Press on off button 8
- Press operation mode selector but ton several times and select the opera tion mode of your choice as follows 8
- A up and down direction 9
- Adjustment 9
- Air flow direction adjust 9
- B left and right direction 9
- Explanation of heating operation 9
- Fan speed control 9
- Press fan speed control button 9
- Press temperature setting button and program the setting temperature 9
- Press the air flow direction adjust button to select the air direction as shown below 9
- Regarding outside air temperature and heat ing capacity 9
- Temperature setting 9
- B left and right direction 10
- Movement of the air flow flap 10
- Optimum operation 10
- Press the programming time button and set the time for stopping or starting the system 10
- Press the timer mode start stop button several times and select the mode on the display 10
- Press the timer on off button 10
- Program timer operation 10
- Programming time 10
- Timer mode start stop 10
- Timer on off 10
- How to clean the air filter 11
- Important 11
- Maintenance for service personnel 11
- Turn off the main power supply switch when it is not used for long periods of time when the main power switch is turned on some watts of electricity is being used even if the system is not operating turn off the main power supply switch for saving energy when reoperating turn on the main power supply switch 6hours before operation for smooth running refer to maintenance 11
- How to clean air outlet and out side panels 12
- How to clean the suction grille 12
- Open the suction grille and pull the knob on the back of the suction grille forward refer to fig 4 12
- Start up after a long stop 12
- What to do when stopping the sys tem for a long period 12
- Not malfunction of the air conditioner 13
- The system does not restart immediately when tempera ture setting button is returned to the former position after pushing the button 13
- Indoor unit no in which a malfunction occurs 14
- Inspection display 14
- Malfunction code 14
- Operation lamp 14
- Trouble shooting 14
- English 12 15
- Specifications 15
- These specifications are in compliance with saso386 15
Похожие устройства
- Daikin FH50BVE Инструкция по эксплуатации
- Daikin FH60BVE Руководство по эксплуатации
- Daikin FH60BVE Инструкция по эксплуатации
- Daikin FH71BVE Руководство по эксплуатации
- Daikin FH71BVE Инструкция по эксплуатации
- Daikin FH6100BVE Руководство по эксплуатации
- Daikin FH6100BVE Инструкция по эксплуатации
- Daikin FH125BVE Руководство по эксплуатации
- Daikin FH125BVE Инструкция по эксплуатации
- Daikin FHY50BVE Руководство по эксплуатации
- Daikin FHY50BVE Инструкция по эксплуатации
- Daikin FHY60BVE Руководство по эксплуатации
- Daikin FHY60BVE Инструкция по эксплуатации
- Daikin FHY71BVE Руководство по эксплуатации
- Daikin FHY71BVE Инструкция по эксплуатации
- Daikin FHY100BVE Руководство по эксплуатации
- Daikin FHY100BVE Инструкция по эксплуатации
- Daikin FHY125BVE Руководство по эксплуатации
- Daikin FHY125BVE Инструкция по эксплуатации
- Daikin FHY35BVE Руководство по эксплуатации