Daikin FH125BVE [12/16] How to clean air outlet and out side panels

Daikin FH35BVE [12/16] How to clean air outlet and out side panels
9 English
4. Fix the air filter.
Set the hatch of the air filter to the fook of the
suction grille, and fix the air filter.
(Refer to Fig. 5)
5. Close the suction grille.
Refer to item No. 1.
6. After turning on the power, press FILTER
SIGN RESET button.
The “TIME TO CLEAN AIR FILTER” display van-
ishes.
HOW TO CLEAN AIR OUTLET AND OUT-
SIDE PANELS
Clean with soft cloth.
When it is difficult to remove stains, use water or
neutral detergent.
When the flap is extremely contaminated, remove
it as below and clean or exchange it.
(Flap for exchange is optional)
NOTE
Do not use gasoline, benzene, thinner, polishing
powder, liquid insecticide. It may cause discolor-
ing or warping.
Do not let the indoor unit get wet. It may cause an
electric shock or a fire.
Do not scrub firmly when washing the blade with
water.
The surface sealing may peel off.
Do not use water or air of 50°C or higher for clean-
ing air filters and outside panels.
HOW TO CLEAN THE SUCTION GRILLE
1. Open the suction grille.
Slide both knobs and then pull them downward.
(Do the same procedure for closing.)
2. Remove the air filter.
Refer to “HOW TO CLEAN THE AIR FILTER”.
(Refer to Fig. 2)
3. Remove the suction grille.
Open the suction grille and pull the knob on the
back of the suction grille forward. (Refer to Fig 4)
4. Clean the suction grille.
Wash with a soft bristle
brush and neutral deter-
gent or water, and dry
throughly.
When very grimy
Directly apply the type of detergent used for
cleaning ventilation fans or ovens, wait 10 min-
utes, and then rinse with water.
NOTE
Do not wash the air conditioner with hot water of
more than 50°C, as doing so may result in discol-
oration and/or deformation.
5. Fix the air filter.
Refer to “HOW TO CLEAN THE AIR FILTER ”.
6. Fix the suction grille.
Refer to item No. 2.
7. Close the suction grille.
Refer to item No. 1.
START UP AFTER A LONG STOP
Confirm the following
Check that the air inlet and outlet are not blocked.
Remove any obstacle.
Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.
Clean the air filter and outside panels
After cleaning the air filter, make sure to attach it.
Turn on the main power supply switch
The display on the remote controller will be shown
when the power is turned on.
To protect the unit, turn on the main power switch
at least 6 hours before operation.
WHAT TO DO WHEN STOPPING THE SYS-
TEM FOR A LONG PERIOD
Turn on FAN OPERATION for a half day and dry
the unit.
Refer to “FAN OPERATION”.
Cut off the power supply.
When the main power switch is turned on, some
watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving
energy.
The display on the remote controller will vanish
when the main power switch is turned off.
Clean the air filter and the exterior.
Be sure to replace the air filter to its original place
after cleaning. Refer to “MAINTENANCE”.
01_EN_3P170549-4.fm Page 9 Friday, December 9, 2005 11:49 AM