Daikin FHY71BVE [28/40] Twin triple double twin multi

Daikin FHYC125KVE [28/40] Twin triple double twin multi
53 54
Motor output
Compressor
Type
°
CWB
Cooling
Heating
Certified
operation range
°
CDB
12 to 25
15 to 27
----------
71
FDYM03FAV1
3.19/3.19 (V1), 3.17/3.17 (Y1)
20
706
39
295
X
1,100
X
680
42
100
FDYM04FAV1
4.00/4.00 (V1), 3.95/3.95 (Y1)
26
917
39
295
X
1,500
X
680
56
125
FDYM05FAV1
4.99/4.99
35
1,235
44
295
X
1,500
X
680
57
140
FDYM06FAV1
RY71LUV1
RY71LUY1
RY100LUV1
RY100LUY1
37
1,306
46
295
X
1,500
X
680
57
26,600/26,200
7.8/7.7
6,700/6,600
27,000
7.9
6,800
35,700/35,300
10.5/10.4
9,000/8,900
38,100
11.2
9,600
44,500/43,600
13.0/12.8
11,200/11,000
49,400/48,400
12,500/12,200
48,400
14.2
14.5/14.2
56,000
16.3
12,200 14,000
2.95 (V1), 2.92 (Y1) 3.91 (V1), 3.86 (Y1) 4.75
5.10/5.10
4.96
kW
Btu/h
kcal/h
Btu/h
kcal/h
Heating capacity
2
kW
kW
kWHeating
2
Cooling
1a/1b
Power consumption
°
CDB
Cooling
Heating
Certified
operation range
°
CWB
Model
Name
Indoor
unit
Indoor unit
Outdoor unit
Dimensions (H
X
W
X
D)
Colour
mm
Sound level (H)
3
dB(A)
kW
Refrigerant charge (R-22)
kg
Sound level (Cooling/Heating)
3
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Piping
connections
mm
Liquid (Flare)
mm
Gas (Flare)
mm
Drain Indoor unit
Outdoor unit
Machine weight
kg
m
3
/min
cfm
98 (10) 98 (10) 98 (10) 98 (10)
Pa(mmH
2
O)
Outdoor
unit
Colour
mm
-10 to 15
2.24
2.8 (Charged for 30 m)
770
X
900
X
320
73 (V1), 72 (Y1)
3.00
3.7 (Charged for 30 m)
1,170
X
900
X
320
89 (V1), 86 (Y1)
3.75
3.7 (Charged for 30 m)
4.50
4.1 (Charged for 30 m)
1,170
X
900
X
320
101
1,345
X
900
X
320
112
Heat insulation
Both liquid and gas piping
48/49 49/52 49/52 54/56
Max. interunit piping length
50 (equivalent length 70 m)
m
m
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
-5 to 46
30
RY125LUY1 RY140LUY1
Airflow rate (H)
External static pressure
Fan
Ivory white
Hermetically sealed scroll type
Max. installation level difference
Cooling capacity
1a/1b
Power supply
V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
140
30
---------
Both liquid and gas piping
Ivory white
Hermetically sealed scroll type
200 250 400 500
4.5
4.1
50 (equivalent length 70 m)
9.05.5
5.54.0
(Charged for 30 m) (Charged for 5 m) (Charged for 5 m)
5.5
(Charged for 5 m)
X
2 (Charged for 5 m)
X
2
54/56 60/62 61/63
-5 to 46
-10 to 15 -10 to 15
0 to 50
1,440
X
1,280
X
690
206
1,220
X
1,280
X
690
180
1,345
X
900
X
320
112
Motor output
Compressor
Type
Model
Name
Indoor unit
Outdoor unit
Cooling capacity
1a/1b
kW
Btu/h
kcal/h
Btu/h
kcal/h
Heating capacity
2
kW
kW
kWHeating
2
Cooling
1a/1b
Power consumption
°
CDB
Cooling
Heating
Certified
operation range
°
CWB
°
CWB
Cooling
Heating
Certified
operation range
°
CDB
Indoor
unit
Colour
Sound level (H)
3
dB(A)
kW
Refrigerant charge (R-22)
kg
Sound level (Cooling/Heating)
3
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Dimensions(H
X
W
X
D)
5
mm
Machine weight
kg
Piping
connections
mm
Liquid (Flare)
mm
Gas
mm
Drain Indoor unit
Outdoor unit
Airflow rate (H)
m
3
/min
cfm
Outdoor
unit
Colour
mm
Heat insulation
Max. interunit piping length
m
m
Max. installation level difference
Power supply
Fan External static pressure
Driving system
Pa(mmH
2
O)
RY140LUY1
12,500/12,220
14.5/14.2
Y1: 3 phase, 380–415 V (4 wires), 50 Hz
FDY08KAY1
80 94
RY200KUY1
19,300/19,100
22.5/22.2
49,500/48,500
76,800/75,700
13,200
15.3
20,000
23.2
52,200
79,200
FDY06KAY1
105
27.6/27.1
94,200/92,500
23,700/23,300
29.5
100,700
25,400
RY250KUY1
53
161
58
187
60
FDY10KAY1 FDY15KAY1
RY200KUY1
X
2
RY250KUY1
X
2
FDY20KAY1
Belt drive
450
X
1,130
X
850 500
X
1,130
X
850 500
X
1,330
X
850 625
X
1,620
X
850 625
X
1,980
X
850
52 68 83
136 166
1,835
108 (11)
118 (12)
147 (15)
2,400 2,929
4,800 5,859
5.14/5.14
4.54
7.2/7.1
6.1
9.3/9.2
8.8
44.0/43.5
150,000/148,000
37,800/37,400
44.8
153,000
38,500
14.4/14.2
12.2
53.9/53.0
184,000/181,000
46,400/45,600
56.8
194,000
48,800
18.5/18.3
17.6
15 to 27
12 to 25 14 to 25
51
5.5
X
2
180
X
2
(1,220
X
1,280
X
690
)
X
2
60/62
4
9.0
X
2
206
X
2
(1,440
X
1,280
X
690
)
X
2
61/63
4
0 to 50
-10 to 15
1B
3/4B
4.0
Note :
Models RY200KU and RY250KU are recommended for commercial facilities.
1
Rated cooling capacities are based on the following conditions:
1a
Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
1b
Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.)
2
Rated heating capacities are based on the following conditions:
Suction temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
4
Specification for outdoor unit is for a single unit only.
5
Without control box.
o
/
9.5
o
/
15.9
o
/
9.5
o
/
19.1
I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32
o
I.Do
/
25
X
O.Do
/
32
o
/
9.5
o
/
19.1
o
/
9.5
o
/
19.1
o
/
26.0 (Hole) o
/
26.0 (Hole) o
/
26.0 (Hole) o
/
26.0 (Hole)
o
/
15.9
o
/
28.6 (Flange)
o
/
12.7
X
2
o
/
25.4
X
2 (Flange)
o
/
15.9
X
2
o
/
28.6
X
2 (Flange)
---------
o
/
12.7
o
/
25.4 (Flange)
o
/
9.5
o
/
19.1 (Flare)
o
/
26.0 (Hole)
Simultaneous operation system
TWIN & TRIPLE & DOUBLE TWIN MULTI
Type
Motor output
Compressor
Model
Name
Indoor unit
Outdoor unit
71 100 125
RY140LUY1
140
FHYC71KVE
X
2
CEILING MOUNTED CASSETTE TYPE
30
kW
Indoor
unit
3
Dimensions
(H
X
W
X
D)
Colour
Cooling capacity
1a/1b
Btu/h
kcal/h
mm
mm
Sound level (H/L)
4
dB(A)
kW
Refrigerant charge (R-22)
kg
Sound level
(Cooling/Heating)
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Unit
Both liquid and gas piping
Heat insulation
Decoration panel
Unit
Decoration panel
Machine
weight
kg
kg
Unit
Decoration panel
Airflow rate (H)
m
3
/min
cfm
Outdoor
unit
Colour
-------------
White
°
CDB
Ivory white
Hermetically sealed scroll type
200 250
49,400/48,400
14.5/14.2
12,500/12,200
4.50
4.1
50 (equivalent length 70 m)
Piping
connections
mm
Liquid (Flare)
Max. interunit piping length
mm
Gas
mm
mm
m
m
Drain
Indoor unit
Outdoor unit
Max. installation level difference
RY200KUY1
FHYC100KVE
X
2
RY250KUY1
FHYC125KVE
X
2
Power supply
VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
RY140LUY1
140
FHYC50KVE
X
3
529
33/29
30
Both liquid and gas piping
-------------
White
Ivory white
Hermetically sealed scroll type
15
230
X
840
X
840
24
40
X
950
X
950
5
RY200KUY1
200
FHYC71KVE
X
3
RY200KUY1
200
FHYC50KVE
X
4
RY250KUY1
250
FHYC60KVE
X
4
50 (equivalent length 70 m)
76,800/75,800
22.5/22.2
19,400/19,100
92,500/90,800
27.1/26.6
23,300/22,900
9.0
76,800/75,800
22.5/22.2
19,400/19,100
22.7
77,500
19,500
49,400/48,400
14.5/14.2
12,500/12,200
16.3
56,000
14,000
22.7
77,500
19,500
76,800/75,800
22.5/22.2
19,400/19,100
56,000
16.3
14,000
97,000
28.4
24,400
92,500/90,800
27.1/26.6
23,300/22,900
97,000
28.4
24,400
4.95/4.95
4.84
77,500
22.7
19,500
5.5
5.54.0
VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Model
Name
Cooling
1a/1b
Heating
2
Power
consumption
kW
kW
kWHeating capacity
2
Btu/h
kcal/h
Cooling
Heating
Certified
operation range
Type
Motor output
Compressor
Cooling
Heating
Certified
operation range
°
CWB
°
CWB
°
CDB
Indoor unit
Outdoor unit
kW
Indoor
unit
3
Dimensions
(H
X
W
X
D)
Colour
Cooling capacity
1a/1b
Btu/h
kcal/h
mm
mm
Sound level (H/L)
4
dB(A)
kW
Refrigerant charge (R-22)
kg
Sound level
(Cooling/Heating)
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Unit
Heat insulation
Decoration panel
Unit
Decoration panel
Machine
weight
kg
kg
Unit
Decoration panel
Airflow rate (H)
m
3
/min
cfm
Outdoor
unit
Colour
°
CDB
Piping
connections
mm
Liquid (Flare)
Max. interunit piping length
mm
Gas
mm
mm
m
m
Drain Indoor unit
Outdoor unit
Max. installation level difference
Power supply
Cooling
1a/1b
Heating
2
Power
consumption
kW
kW
kWHeating capacity
2
4
Btu/h
kcal/h
Cooling
Heating
Certified
operation range
Cooling
Heating
Certified
operation range
°
CWB
°
CWB
°
CDB
FHYC35KVE
X
2
RY71LUV1
RY71LUY1
14
230
X
840
X
840
24
40
X
950
X
950
5
26,600/26,200
7.8/7.7
6,700/6,600
27,000
7.9
6,800
770
X
900
X
320
2.24
2.8
(Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 5 m) (Charged for 5 m)
73 (V1), 72 (Y1)
48/49
494
33/29
2.94 (V1), 2.92 (Y1)
3.11/3.11 (V1), 3.09/3.09 (Y1)
RY100LUV1
RY100LUY1
FHYC50KVE
X
2
15
230
X
840
X
840
24
40
X
950
X
950
5
35,700/35,300
10.5/10.4
9,000/8,900
38,100
11.2
9,600
1,170
X
900
X
320
89 (V1), 86 (Y1)
3.00
3.7
49/52
529
33/29
3.69 (V1), 3.65 (Y1)
3.98/3.98 (V1), 3.93/3.93 (Y1)
RY125LUY1
125
FHYC60KVE
X
2
19
230
X
840
X
840
24
40
X
950
X
950
5
44,500/43,600
13.0/12.8
11,200/11,000
48,400
14.2
12,200
1,170
X
900
X
320
3.75
3.7
49/52 54/56 60/62 61/63
101
12 to 25
15 to 27 15 to 27
-5 to 46
-10 to 15 -10 to 15
14 to 25
0 to 50
12 to 25
15 to 27 15 to 27
14 to 25
670
35/30
19
230
X
840
X
840
24
40
X
950
X
950
5
670
35/30
19
230
X
840
X
840
24
40
X
950
X
950
5
670
35/30
4.73
4.94/4.94
4.84
4.95/4.95
6.5
7.7/7.6
19
230
X
840
X
840
24
40
X
950
X
950
5
670
35/30
28
988
288
X
840
X
840
28
33
1,164
42/3639/34
288
X
840
X
840
40
X
950
X
950 40
X
950
X
950
28
5 5
1,440
X
1,280
X
690
206
1,220
X
1,280
X
690
180
9.0
5.5 (Charged for 5 m)
61/63
0 to 50-5 to 46
-10 to 15 -10 to 15
1,440
X
1,280
X
690
206
5.5
4.0 (Charged for 5 m)
60/62
1,220
X
1,280
X
690
180
5.5
4.0 (Charged for 5 m)
60/62
1,220
X
1,280
X
690
180
1,345
X
900
X
320
112
4.50
4.1 (Charged for 30 m)
54/56
1,345
X
900
X
320
112
529
33/29
15
230
X
840
X
840
24
40
X
950
X
950
5
6.5
7.7/7.6
6.5
7.7/7.6
9.2
9.7/9.7
9.2
9.7/9.7
4
Note :
Models RY200KU and RY250KU are recommended for commercial facilities.
1
Rated cooling capacities are based on the following conditions:
1a
Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
1b
Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.)
2
Rated heating capacities are based on the following conditions:
Indoor temp., 20°CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal). (RY71LU-RY140LU is 7.5 m.)
3
Values shown are for a single unit only.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
o
/
9.5
o
/
15.9 (Flare)
I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32
o
/
26.0 (Hole)
o
/
9.5
o
/
19.1 (Flare)
o
/
26.0 (Hole)
o
/
9.5
o
/
19.1 (Flare)
o
/
26.0 (Hole)
---------
o
/
15.9
o
/
28.6 (Flange)
---------
o
/
12.7
o
/
25.4 (Flange)
o
/
9.5
o
/
19.1 (Flare)
o
/
26.0 (Hole)
I.Do
/
25
X
O.Do
/
32
---------
o
/
15.9
o
/
28.6 (Flange)
I.Do
/
25
X
O.Do
/
32
---------
o
/
12.7
o
/
25.4 (Flange)
I.Do
/
25
X
O.Do
/
32
---------
o
/
12.7
o
/
25.4 (Flange)
o
/
9.5
o
/
19.1 (Flare)
I.Do
/
25
X
O.Do
/
32
o
/
26.0 (Hole)

Содержание

Скачать