Daikin FAY71LVE [6/15] Operation range
![Daikin FAY71LVE [6/15] Operation range](/views2/1764540/page6/bg6.png)
3 English
Do not place a burner or heater at a place
directly exposed to the wind from the air con-
ditioner.
Incomplete combustion of the burner or heater
may result.
Do not allow a child to mount on the outdoor
unit or avoid placing any object on it.
Falling or tumbling may result in injury.
Do not expose animals and plants directly to
the wind.
Adverse influence to animals and plants may result.
Do not wash the air conditioner with water.
Electric shock or fire may result.
Do not install the air conditioner at any place
where flammable gas may leak out.
If the gas leaks out and stays around the air con-
ditioner, a fire may break out.
Be sure to install an earth leakage breaker.
Unless it is installed, electric shock or fire may
result.
Be sure the air conditioner is electrically
grounded.
Do not connect the grounding conductor to a gas
pipe, water pipe, lightning arrester, and the
grounding conductor for a telephone.
Imperfect grounding work may result in an elec-
tric shock.
Execute complete drain piping for perfect
drainage.
Incomplete piping may result in a water leakage.
The appliance is not intended for use by
young children or infirm persons without
supervision.
Young children should be supervised to
ensure that they do not play with the appliance.
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
3. OPERATION RANGE
OUT-
DOOR
UNIT
INDOOR
OUTDOOR
TEMPERATURE
(
°
C)
TEMPERA-
TURE (
°
C)
HUMIDITY
COOL-
ING
ONLY
TYPE
R71
RP71
D
B
20 to 35
80% or
below
D
B
21 to 46
W
B
14 to 25
HEAT
PUMP
TYPE
RY71
RYP71
D
B
18 to 35
80% or
below
D
B
– 5 to 46
W
B
12 to 25
HEATING
D
B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.
Regarding places for installation
• Is the air conditioner installed at a well-venti-
lated place where there are no obstacles
around?
• Do not use the air conditioner in the following
places.
a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring
resort
d.Where there are considerable voltage fluctua-
tions such as a factory or plant
e.Vehicles and vessels
f
.Where there is much spray of oil and vapor such
as a cookery, etc.
g.Where there are machines generating electro-
magnetic waves
h.Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply cir-
cuit is provided for this air conditioner and
that all electrical work is carried out by quali-
fied personnel according to local laws and
regulations.
Pay attention to running noises, too
• Are the following places selected?
a.A place that can sufficiently withstand the
weight of the air conditioner with less running
noises and vibrations.
b.
A place where the hot wind discharged from the air
outlet of the outdoor unit and the running noises.
OUT-
DOOR
UNIT
INDOOR
TEMPERATURE (
°
C)
OUTDOOR
TEMPERATURE
(
°
C)
HEAT
PUMP
TYPE
RY71
RYP71
D
B
15 to 27
D
B
– 9 to 21
W
B
– 10 to 15
4. INSTALLATION SITE
01_EN_3P083810-3.fm Page 3 Thursday, December 26, 2002 10:09 AM
Содержание
- Fay71lve fayp71lv1 1
- Models wall mounted type 1
- Operation manual 1
- Split system air conditioner 1
- Áëàãîäàðèì çà ïîêóïêó êîíäèöèîíåðà daikin äî íà àëà ðàáîòû ñ êîíäèöèîíåðîì âíèìàòåëüíî èçó èòå äàííîå ðóêîâîäñòâî ïî ýêñïëóàòàöèè â íåì èçëàãàþòñÿ ïðàâèëà ïîëüçîâàíèÿ è ïðèâîäÿòñÿ ðåêîìåíäàöèè ïî ïîèñêó è óñòðàíåíèþ íåèñïðàâíîñòåé â äàííîì ðóêîâîäñòâå ðàññìàòðèâàåòñÿ òîëüêî êîìíàòíûé áëîê èñïîëüçóéòå åãî âìåñòå ñ ðóêîâîäñòâîì äëÿ íàðóæíîãî áëîêà ïîñëå èçó åíèÿ ðóêîâîäñòâà ñîõðàíèòå åãî äëÿ ñïðàâêè 2
- Óáò åõ áñéóôïýìå ðïõ áãïñüóáôå áõôþ ôçí êëéìáôéóôéêþ óõóêåõþ ôçò daikin äéáâüóôå ðñïóåêôéêü áõôü ôï åã åéñßäéï ñþóçò ðñéí ñçóéìïðïéþóåôå ôçí êëéìáôéóôéêþ óõóêåõþ èá óáò åîçãþóåé ðùò íá ñçóéìïðïéåßôå ôç ìïíüäá óùóôü êáé èá óáò âïçèþóåé áí ðáñïõóéáóôåß êüðïéï ðñüâëçìá áõôü ôï åã åéñßäéï ðåñéãñüöåé ìüíï ôçí åóùôåñéêþ ìïíüäá ñçóéìïðïéþóôå ôï ìáæß ìå ôï åã åéñßäéï ëåéôïõñãßáò ãéá ôçí åîùôåñéêþ ìïíüäá áöïý äéáâüóåôå ôï åã åéñßäéï öõëüîôå ôï ãéá ìåëëïíôéêþ ñþóç 2
- Contents 4
- Indoor unit 4
- Names and functions of parts 4
- Outdoor unit 4
- Precautions for group control system or two remote controller control system 4
- Unit with remote controller 4
- Unit without romote controller when used as simultaneous operation system 4
- What to do before opera tion 4
- What to do before operation 4
- Safety considerations 5
- Installation site 6
- Operation range 6
- Pay attention to running noises too 6
- Regarding places for installation 6
- Regarding wiring 6
- And display on the remote controller 7
- Name and function of each switc 7
- Name and function of each switch and display on the remote controller 7
- Regarding drainage of drain piping 7
- Adjustment 8
- Cooling heating automatic fan and program dry operation 8
- Defrost operation 8
- Explanation of heating operation 8
- On off 8
- Operation mode selec tor 8
- Operation procedure 8
- Press on off button 8
- Press operation mode selector but ton several times and select the opera tion mode of your choice as follows 8
- Press temperature setting button and program the setting temperature 8
- Regarding outside air temperature and heat ing capacity 8
- Temperature setting 8
- A up and down adjustment 9
- A up and down direction 9
- Air flow direction adjust 9
- B left and right direction 9
- Cooling 9
- Fan speed control 9
- Heating 9
- Movement of the air flow flap 9
- Press fan speed control button 9
- Press the air flow direction adjust button to select the air direction as follow ing 9
- Recommended flap positions 9
- Optimum operation 10
- Press the programming time button and set the time for stopping or starting the sys tem 10
- Press the timer mode start stop button several times and select the mode on the display 10
- Press the timer on off button 10
- Program timer operation 10
- Programming time 10
- Timer mode start stop 10
- Timer on off 10
- How to clean the air filter 11
- How to clean the air outlet and exterior 11
- How to clean the front panel 11
- Important 11
- Maintenance for service personnel 11
- Not malfunction of the air conditioner 12
- Start up after a long stop 12
- What to do when stopping the sys tem for a long period 12
- Trouble shooting 13
- Indoor unit no in which a malfunction occurs 14
- Inspection display 14
- Malfunction code 14
- Operation lamp 14
Похожие устройства
- Daikin FAY71LVE Инструкция по монтажу
- Daikin FAY71LVE Инструкция по эксплуатации
- Daikin FAYP71LV1 Руководство по эксплуатации
- Daikin FAYP71LV1 Инструкция по монтажу
- Daikin FAYP71LV1 Инструкция по эксплуатации
- Candy CCFET 6182XHPU Инструкция по эксплуатации
- Candy CCFET 6182XHPU Инструкция по эксплуатации EN
- Candy CCLN 6172WH Инструкция по эксплуатации
- Candy CCLN 6172WH Инструкция по эксплуатации EN
- Daikin FAQ71BUV1B Инструкция по эксплуатации
- Daikin FAQ71BUV1B Инструкция по монтажу
- Candy CCMN 7182 B Инструкция по эксплуатации
- Candy CCMN 7182 W Инструкция по эксплуатации
- Candy CCMN 7182 W Инструкция по эксплуатации EN
- Daikin FAQ71BVV1B Инструкция по эксплуатации
- Daikin FAQ71BVV1B Технические данные
- Candy CCODS 5142WH Инструкция по эксплуатации
- Candy CCODS 5142WH Инструкция по эксплуатации EN
- Daikin FAQ100BVV1B Инструкция по эксплуатации
- Daikin FAQ100BVV1B Технические данные