Daikin FDYM04FAVAL [10/14] Cleaning the air filter
![Daikin FDM04FAV1 [10/14] Optimum operation](/views2/1764744/page10/bga.png)
7 English
TIMER ON/OFF
Press the TIMER ON/OFF button.
The timer setting procedure ends.
The display “ or ” changes from flash-
ing light to a constant light.
Refer to figure 4 on page [1]
NOTE
•
When setting the timer Off and On at the same time,
repeat the above procedure from to once again.
When the timer is programmed to stop the system
after 3 hours and start the system after 4 hours, the
system will stop after 3 hours and then 1 hour later
the system will start.
• After the timer is programmed, the display shows
the remaining time.
• Press the TIMER ON/OFF button once again to
cancel programming. The display vanishes.
Observe the following precautions to ensure the
system operates.
•
Adjust the room temperature properly for a comfort-
able environment. Avoid excessive heating or cooling.
• Prevent direct sunlight from entering a room dur-
ing cooling operation by using curtains or blinds.
• Ventilate the room regularly.
Using the unit for long periods of time requires
attentive ventilation of the room.
•
Keep doors and windows closed. If the doors and
windows remain open, room air will flow out and
cause to decrease the effect of cooling and heating.
• Do not place other heaters directly below the
indoor unit.
They may deform due to the heat.
• Never place objects near the air inlet and the air
outlet of the unit. It may cause deterioration in the
effect or stop in the operation.
• Turn off the main power supply switch when it is
not used for long periods of time. When the main
power switch is turned on, some watts of electric-
ity is being used even if the system is not operat-
ing. Turn off the main power supply switch for
saving energy. When reoperating, turn on the
main power supply switch 6hours before opera-
tion for smooth running (Refer to MAINTE-
NANCE).
• When the display shows “ ” (TIME TO CLEAN
AIR FILTER), ask a qualified service person to
clean the filters (Refer to MAINTENANCE).
3
7. OPTIMUM OPERATION
ONLY A QUALIFIED SERVICE PERSON IS
ALLOWED TO PERFORM MAINTENANCE
IMPORTANT!
• BEFORE OBTAINING ACCESS TO TERMINAL
DEVICES, ALL POWER SUPPLY CIRCUITS
MUST BE INTERRUPTED
• To clean the air conditioner, be sure to stop oper-
ation, and turn the power switch off. Otherwise, an
electric shock and injury may result.
• Do not wash the air conditioner with water
Doing so may result in an electric shock.
• Be careful with a scaffold or staging
Caution must be exercised because of work at a
high place.
CLEANING THE AIR FILTER
• Be sure always to clean the unit before use at the
beginning of summer and winter. (Dirt and dust
caught in the air filter cause a drop in airflow,
which leads to a decline in performance.)
• When using the unit in a location where dirt may
easily accumulate, clean the unit more frequently.
Once every 2 weeks is recommended.
NOTE
• The air filter and the suction grille are commer-
cially available.
• Ask your DAIKIN dealer how to clean them.
HOW TO CLEAN AIR OUTLET, SUCTION
GRILLE AND OUTSIDE PANELS
• Clean with soft cloth.
• When it is difficult to remove stains, use water or
neutral detergent.
NOTE
• Do not use gasoline, benzene, thinner, polishing
powder, liquid insecticide. It may cause discolor-
ing or warping.
• Do not let the indoor unit get wet. It may cause an
electric shock or a fire.
START UP AFTER A LONG STOP
Confirm the following
• Check that the air inlet and outlet are not blocked.
Remove any obstacle.
• Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.
Clean the air filter and outside panels
• After cleaning the air filter, make sure to attach it.
8. MAINTENANCE
(FOR SERVICE PERSONNEL)
01_EN_3PN02535-7P.fm Page 7 Friday, December 9, 2005 1:08 PM
Содержание
- Operation manual 1
- Split system air conditioner 1
- Contents 4
- Indoor unit 4
- Names and functions of parts 4
- Outdoor unit 4
- Precautions for group control system or two remote controller control system 4
- Safety considerations 4
- Unit with remote controller 4
- What to do before opera tion 4
- What to do before operation 4
- Cooling 6
- English 6
- If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes water may drop from the indoor unit 6
- Never expose little children plants or ani mals directly to the air flow adverse influence to little children animals and plants may result do not wash the air conditioner with water an electric shock or fire may result do not install the air conditioner at any place where flammable gas may leak out if the gas leaks out and stays around the air con ditioner a fire may break out execute complete drain piping for perfect drainage incomplete piping may result in a water leakage the appliance is not intended for use by young children or infirm persons without supervision young children should be supervised to ensure that they do not play with the appli ance consult with installation contractor for cleaning the inside of the air conditioner wrong cleaning may make the plastics parts broken or cause failure of water leakage or elec tric shock do not touch the air inlet or aluminium fin of the air conditioner otherwise injury may be caused do not place objects in direct proximity of the outdo 6
- Operation range 6
- And display on the remote controller 7
- Installation site 7
- Name and function of each switc 7
- Name and function of each switch and display on the remote controller 7
- Pay attention to running noises too 7
- Regarding drainage of drain piping 7
- Regarding places for installation 7
- Regarding wiring 7
- Cooling heating automatic fan and program dry operation 8
- Operation mode selec tor 8
- Operation procedure 8
- Press operation mode selector but ton several times and select the opera tion mode of your choice as follows 8
- Use this button for setting tempera ture 8
- Adjustment 9
- Explanation of heating operation 9
- Fan speed control 9
- On off 9
- Press fan speed control button 9
- Press on off button 9
- Press temperature setting button and program the setting temperature 9
- Press the programming time button and set the time for stopping or starting the sys tem 9
- Press the timer mode start stop button several times and select the mode on the display 9
- Program timer operation 9
- Programming time 9
- Regarding outside air temperature and heat ing capacity 9
- Temperature setting 9
- Timer mode start stop 9
- Cleaning the air filter 10
- How to clean air outlet suction grille and outside panels 10
- Important 10
- Maintenance for service personnel 10
- Optimum operation 10
- Press the timer on off button 10
- Start up after a long stop 10
- Timer on off 10
- Not malfunction of the air conditioner 11
- What to do when stopping the sys tem for a long period 11
- Inspection display malfunction code 12
- Operation lamp 12
- Trouble shooting 12
- English 10 13
- Specifications 13
- These specifications are in compliance with saso386 13
Похожие устройства
- Daikin FDYM05FAVAL Руководство по эксплуатации
- Daikin FDM03FAVAL Руководство по эксплуатации
- Daikin FDM04FAVAL Руководство по эксплуатации
- Daikin FDM05FAVAL Руководство по эксплуатации
- Daikin FDYM06FAVAL Руководство по эксплуатации
- Daikin FDYM60FAVAL Руководство по эксплуатации
- Daikin FDYM60FAVAL Сервис мануал
- Daikin FDYM60FAV1C Руководство по эксплуатации
- Daikin FDYM60FAV1C Сервис мануал
- Daikin FDYM03FAV1C Руководство по эксплуатации
- Daikin FDYM03FAV1C Сервис мануал
- Candy CDDE 4475 Инструкция по эксплуатации
- Candy CDDE 4475 Инструкция по эксплуатации EN
- Candy CDDN 4475 Инструкция по эксплуатации
- Candy CDDN 4475 Инструкция по эксплуатации EN
- Candy CDM 3665 E Инструкция по эксплуатации
- Candy CDNE 3760 Инструкция по эксплуатации
- Candy CDNE 3760 Инструкция по эксплуатации EN
- Candy CDNE 3765 Инструкция по эксплуатации
- Candy CDNE 3765 Инструкция по эксплуатации EN