Daikin FDYM60FAVAL [11/14] Not malfunction of the air conditioner
![Daikin FDYM04FAVAL [11/14] Not malfunction of the air conditioner](/views2/1764744/page11/bgb.png)
English 8
Turn on the main power supply switch
• The display on the remote controller will be shown
when the power is turned on.
• To protect the unit, turn on the main power switch
at least 6 or 12 hours before operation.
WHAT TO DO WHEN STOPPING THE SYS-
TEM FOR A LONG PERIOD
Turn on FAN OPERATION for a half day and dry
the unit.
• Refer to “FAN OPERATION”.
Cut off the power supply.
• When the main power switch is turned on, some
watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving
energy.
• The display on the remote controller will vanish
when the main power switch is turned off.
The following symptoms do not indicate air condi-
tioner malfunction
I. THE SYSTEM DOES NOT OPERATE
• The system does not restart immediately after
the ON/OFF button is pressed.
If the OPERATION lamp lights, the system is in
normal condition.
It does not restart immediately because a safety
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again
automatically.
• The system does not restart immediately
when TEMPERATURE SETTING button is
returned to the former position after pushing
the button.
If the OPERATION lamp lights, the system is in
normal condition.
It does not restart immediately because a safety
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again
automatically.
• The system does not start when the display
shows “ ” (UNDER CENTRALIZED
CONTROL) and it flashes for few seconds
after pressing an operation button.
This is because the system is under centralized
control. Flashes on the display indicates that the
system cannot be controlled by the remote con-
troller.
9. NOT MALFUNCTION OF THE AIR
CONDITIONER
• The system does not start immediately after
the power supply is turned on.
Wait one minute until the micro computer is pre-
pared for operation.
II. WHITE MIST COMES OUT OF A UNIT
• When humidity is high during cooling opera-
tion. (In oily or dusty places)
If the inside of an indoor unit is extremely contam-
inated, the temperature distribution inside a room
becomes uneven. It is necessary to clean the
inside of the indoor unit. Ask your Daikin dealer
for details on cleaning the unit. This operation
requires a qualified service person.
• When the system is changed over to HEATING
OPERATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes
steam and exists.
III.NOISE OF AIR CONDITIONERS
• A ringing sound after the unit is started.
This sound is generated by the temperature reg-
ulator working.
It will quiet down after about a minute.
• A continuous flow “Shuh” sound is heard
when the systems is in COOLING or
DEFROST OPERATION.
This is the sound of refrigerant gas flowing
through both indoor and outdoor units.
• A “Shuh” sound which is heard at the start or
immediately after the stop of operation or
which is heard at the start or immediately after
the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop
and flow change.
• A continuous low “Shah” sound is heard
when the system is in COOLING OPERATION
or at a stop.
The noise is heard when the drain pump is in
operation.
• A “Pishi-pishi” squeaking sound is heard
when the system is in operation or after the
stop of operation.
Expansion and contraction of plastic parts caused
by temperature change makes this noise.
IV.DUST FROM THE UNITS
• Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
V. THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
01_EN_3PN02535-7P.fm Page 8 Friday, December 9, 2005 1:08 PM
Содержание
- Operation manual 1
- Split system air conditioner 1
- Contents 4
- Indoor unit 4
- Names and functions of parts 4
- Outdoor unit 4
- Precautions for group control system or two remote controller control system 4
- Safety considerations 4
- Unit with remote controller 4
- What to do before opera tion 4
- What to do before operation 4
- Cooling 6
- English 6
- If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes water may drop from the indoor unit 6
- Never expose little children plants or ani mals directly to the air flow adverse influence to little children animals and plants may result do not wash the air conditioner with water an electric shock or fire may result do not install the air conditioner at any place where flammable gas may leak out if the gas leaks out and stays around the air con ditioner a fire may break out execute complete drain piping for perfect drainage incomplete piping may result in a water leakage the appliance is not intended for use by young children or infirm persons without supervision young children should be supervised to ensure that they do not play with the appli ance consult with installation contractor for cleaning the inside of the air conditioner wrong cleaning may make the plastics parts broken or cause failure of water leakage or elec tric shock do not touch the air inlet or aluminium fin of the air conditioner otherwise injury may be caused do not place objects in direct proximity of the outdo 6
- Operation range 6
- And display on the remote controller 7
- Installation site 7
- Name and function of each switc 7
- Name and function of each switch and display on the remote controller 7
- Pay attention to running noises too 7
- Regarding drainage of drain piping 7
- Regarding places for installation 7
- Regarding wiring 7
- Cooling heating automatic fan and program dry operation 8
- Operation mode selec tor 8
- Operation procedure 8
- Press operation mode selector but ton several times and select the opera tion mode of your choice as follows 8
- Use this button for setting tempera ture 8
- Adjustment 9
- Explanation of heating operation 9
- Fan speed control 9
- On off 9
- Press fan speed control button 9
- Press on off button 9
- Press temperature setting button and program the setting temperature 9
- Press the programming time button and set the time for stopping or starting the sys tem 9
- Press the timer mode start stop button several times and select the mode on the display 9
- Program timer operation 9
- Programming time 9
- Regarding outside air temperature and heat ing capacity 9
- Temperature setting 9
- Timer mode start stop 9
- Cleaning the air filter 10
- How to clean air outlet suction grille and outside panels 10
- Important 10
- Maintenance for service personnel 10
- Optimum operation 10
- Press the timer on off button 10
- Start up after a long stop 10
- Timer on off 10
- Not malfunction of the air conditioner 11
- What to do when stopping the sys tem for a long period 11
- Inspection display malfunction code 12
- Operation lamp 12
- Trouble shooting 12
- English 10 13
- Specifications 13
- These specifications are in compliance with saso386 13
Похожие устройства
- Daikin FDYM60FAVAL Сервис мануал
- Daikin FDYM60FAV1C Руководство по эксплуатации
- Daikin FDYM60FAV1C Сервис мануал
- Daikin FDYM03FAV1C Руководство по эксплуатации
- Daikin FDYM03FAV1C Сервис мануал
- Candy CDDE 4475 Инструкция по эксплуатации
- Candy CDDE 4475 Инструкция по эксплуатации EN
- Candy CDDN 4475 Инструкция по эксплуатации
- Candy CDDN 4475 Инструкция по эксплуатации EN
- Candy CDM 3665 E Инструкция по эксплуатации
- Candy CDNE 3760 Инструкция по эксплуатации
- Candy CDNE 3760 Инструкция по эксплуатации EN
- Candy CDNE 3765 Инструкция по эксплуатации
- Candy CDNE 3765 Инструкция по эксплуатации EN
- Candy CDNF 3760 Инструкция по эксплуатации
- Candy CDNF 3760 Инструкция по эксплуатации EN
- Candy CDNF 3760A Инструкция по эксплуатации
- Candy CDNF 3760A Инструкция по эксплуатации EN
- Candy CDNF 3764 Инструкция по эксплуатации
- Candy CDNF 3764 Инструкция по эксплуатации EN