Stihl SE 62 E [29/492] Connecting to power supply

Stihl SE 62 E [29/492] Connecting to power supply
SE 62, SE 62 E
English
27
Extension tube
SE 62
N Connect suction tubes (1) and (2)
SE 62 E
N Press button (1)
N Retract or extend suction tube (2)
Mount suction tube holder
N Slide the suction tube holder (1) via
the suction tube (distance A approx.
8 cm / 3.150 in.) and secure it with
the screw (2)
Fastening accessories
Fasten accessories on the holders
provided – as shown in picture.
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Depending on the supply voltage and
cord length, the minimum conductor
cross section of the extension cord must
be as follows:
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
N Plug the power cord or extension
cord into a properly installed outlet
0809BA007 KN
1 2
0809BA008 KN
1
2
A
2
0809BA009 KN
1
0809BA010 KN
Connecting to Power Supply
Cord length Minimum cross
section
220 V – 240 V:
up to 20 m 1.5 mm
2
20 m to 50 m 2.5 mm
2
100 V – 127 V:
up to 10 m AWG 14 / 2.0 mm
2
10 m to 30 m AWG 12 / 3.5 mm
2