Daikin FWB06CFN [5/76] Installation example

Daikin FWB04CFN [5/76] Installation example
UT66002764 5
A wide range of wall-mounted controllers is available, including
microprocessor controllers with display.
Electric heating elements complete with safety devices are
available to integrate the hydronic operation.
MAIN COMPONENTS
Structure
Realized in galvanized steel sheet, thermally and acoustically
insulated by self-extinguishing panels class 1.
Height reduced to facilitate installation in a horizontal position,
in false ceilings.
The bearing structure contains the tank for collecting and dis-
charging condensate.
Heat exchanger
High eciency standard with 3 rows, but also available with
4 rows upon request, heat exchangers are made of copper
tube and alluminium ns secured to the tubes by mechanical
expansion.
It is tted with brass manifold and an air valve.The heat exchang-
er, usually with left hand water connections can be turned by
180°.
Available upon request high eciency heat exchanger opti-
mized for district cooling application.
Fans
Double suction centrifugal fans made with ABS or aluminium,
with statically and dynamically balanced forward-curving
blades, directly coupled to the electric motor.
Electric motor
Single-phase asynchronous multi-speed electric motor with per-
manently connected capacitor and thermal protector, mounted
on vibration-damping supports.
Air lter
Washable air lter, made of acrylic bre, ltration class G2 or G3,
applied on the air intake; may be pulled out from below.
Air inlet
Air intake from the front or bottom of the unit, according to sys-
tem requirements.
Installation example
The bearing structure allows to combine a large range of acces-
sories in suction and air delivery in order to obtain the optimized
unit conguration.
ACCESSORIES
Electronic microprocessor control panels with display
FWECSAP
Circuit board for FWECS control
FWECSAC
User interface with display for FWECS controller
FWEC 1
FWEC1 electronic controller with display
FWEC 2
Microprocessor control with display FWEC2
FWEC 3
FWEC3 electronic controller with display
FWHSKA
Humidity sensor for FWEC2,3, FWECS
FWTSKA
Water sensor for FWEC and FWECS controllers
Power interface and regulating louver controllers
EPIMSB6 Power interface for connecting in parallel up to 4 fun coil units to the one controller
Electrical heating elements
EH Heating element with installation kit, relay box and safety devices
Accessories
CDRP1A Condensate drainage pump kit
EDPD Auxiliary water drip tray
Valves
2-way valves, ON/OFF or MUDULATING actuator, 230 V or 24 V power supply, hydraulic kit, for
additional heat exchanger
2-way valve, ON/OFF or MODULATING actuator, 230 V or 24 V power supply, hydraulic kit, for main heat
exchanger
3-way valves, ON/OFF or MODULATING actuator, 230 V or 24 V power supply, hydraulic kit, for
additional heat exchanger
3-way valves, ON/OFF or MODULATING actuator, 230 V or 24 V power supply, hydraulic kit, for main
heat exchanger
2-way valves pressure independent, ON/OFF or MUDULATING actuator, 230 V or 24 V power supply,
hydraulic kit, for main and additional heat exchanger