Daikin FTKS25DVMW9 Сервис мануал онлайн [171/205] 596911

Daikin FTKS20DVMW9 Сервис мануал онлайн [171/205] 596910
SiEBE04-507 Outdoor Unit
Removal Procedure 161
5
Undo the hooks.
Pull and remove the
front panel.
The front panel has 4 hooks.
The fan motor is united with
the front panel.
3. Remove the fan motor. The screw has reverse
winding.
1
Unscrew the washer-
fitted nut (M10) of the
propeller fan with a
spanner.
2
Remove the propeller
fan.
Align mark of the
propeller fan with D-cut
section of the motor shaft
when reassembling.
Step
Procedure Points
(R3243)
Hooks
(R3244)
Propeller fan
(R3245)
D-cut