Daikin FTXV60AV1B [4/40] Warning
![Daikin RXV25AV1B [4/40] Safety precautions](/views2/1772007/page4/bg4.png)
1
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important information
regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING.......... Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ........... Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater,
stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air,
and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even
injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the
refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
• Do not touch any electronic component or terminal when the machine is running, stopping or has been powered off
for less than 30 minutes to prevent the risk of electric shock!
Содержание
- Owner s manual 1
- Attachment 3
- Content 3
- Installation 3
- Installation notice 3
- Maintenance 3
- Malfunction 3
- Operation notices 3
- Screen operation guide 3
- Test and operation 3
- Safety precautions 4
- Warning 4
- Caution 5
- Indoor side db wb c outdoor side db wb c maximum cooling 32 23 43 26 maximum heating 27 24 18 5
- The operating temperature range outdoor temperature is 18 43 c for cooling and 10 24 c for heating operation 5
- Working temperature range 5
- Indoor unit 6
- Outdoor unit 6
- Parts name 6
- At least 50cm 7
- Installation dimension diagram 7
- Space to the obstruction 7
- Selection of installation location 8
- Tools for installation 8
- Grounding requirement 9
- Requirements for electric connection 9
- Safety precaution 9
- And 35 class 10
- Choose the position of piping hole according to the direction of outlet pipe the position of piping hole should be a little lower than the wall mounted frame shown as below 10
- Hang the wall mounting frame on the wall adjust it in horizontal position with the level meter and then point out the screws fixing holes on the wall 2 drill the screw fixing holes on the wall with impact drill the specification of drill head should be the same as the plastic expansion particle and then fill the plastic expansion particles in the holes 3 fix the wall mounting frame on the wall with tapping screws st4 x25ta and then check if the frame is firmly installed by pulling the frame if the plastic expansion particle is loose please drill another fixing hole nearby 10
- Installation of indoor unit 10
- Open a piping hole with the diameter of ø55 or ø70 on the selected outlet pipe position in order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 10
- Recommend the installation location to the client and then confirm it with the client 10
- Step one choosing installation location 10
- Step three open piping hole 10
- Step two install wall mounting frame 10
- Installation of indoor unit 11
- Step five connect the pipe of indoor unit 11
- Step four outlet pipe 11
- Ø55 ø70 11
- Installation of indoor unit 12
- Step seven connect wire of indoor unit 12
- Step six install drain hose 12
- Installation of indoor unit 13
- Installation of indoor unit 14
- Step eight bind up pipe 14
- Step nine hang the indoor unit 14
- Installation of outdoor unit 15
- Step one fix the support of outdoor unit select it according to the actual installation situation 15
- Step three fix outdoor unit 15
- Step two install drain joint only for cooling and heating unit 15
- Installation of outdoor unit 16
- Step five connect outdoor electric wire 16
- Step four connect indoor and outdoor pipes 16
- Installation of outdoor unit 17
- Step six neaten the pipes 17
- Leakage detection 18
- Use vacuum pump 18
- Vacuum pumping 18
- Check after installation 19
- Items to be checked possible malfunction 19
- Method of test operation 19
- Preparation of test operation 19
- Test operation 19
- Configuration of connection pipe 20
- Pipe expanding method 21
- Button 22
- Buttons on remote controller 22
- Fan button 22
- Introduction to icons on display screen 22
- Light button 22
- Mode button 22
- On off button 22
- Save button 22
- Sleep button 22
- Swing button 22
- Timer button 22
- Turbo button 22
- X fan button 22
- Introduction to buttons on remote controller 23
- Introduction to buttons on remote controller 24
- Introduction to buttons on remote controller 25
- Child lock function 26
- Introduction to buttons on remote controller 26
- Introduction to functions of combination buttons 26
- Switchover function for temperature display 26
- Operation guide 27
- Replacement of batteries in remote controller 27
- Clean surface of indoor unit 28
- Cleaning and maintenance 28
- Emergency operation 28
- Clean filter 29
- Cleaning and maintenance 29
- Install filter 29
- Open panel 29
- Remove filter 29
- Checking after active season 30
- Checking before active season 30
- Cleaning and maintenance 30
- Notice for recovery 30
- General phenomenon analysis 31
- Malfunction analysis 31
- Malfunction analysis 32
- Malfunction analysis 33
- Malfunction 34
- Malfunction analysis 34
- Warning 34
- Do not turn on the safety breaker until all work is completed 1 for both outdoor and indoor units strip the insulation from the wire 40mm 2 connect the connection wires between the indoor and outdoor units so that the terminal numbers match tighten the terminal screws securely we recommend a flathead screw driver be used to tighten the screws 3 for connecting outdoor unit to indoor unit use standardized supply cable h05rn 35
- Wiring 35
- Wiring 36
- Wiring diagram 36
- Disposal requirements 37
- Environmental information 37
- Extra refrigerant charge 37
- Instruction appendix 37
- Copyright 2013 daikin 40
Похожие устройства
- Daikin FVXM25A2V1B Инструкция по эксплуатации
- Daikin FVXM25A2V1B Инструкция по монтажу
- Daikin FVXM25A2V1B Справочник установщика
- Daikin FVXM35A2V1B Инструкция по эксплуатации
- Daikin FVXM35A2V1B Инструкция по монтажу
- Daikin FVXM35A2V1B Справочник установщика
- Daikin FVXM50A2V1B Инструкция по эксплуатации
- Daikin FVXM50A2V1B Инструкция по монтажу
- Daikin FVXM50A2V1B Справочник установщика
- Daikin FWXV15AVEB Инструкция по монтажу
- Daikin FWXV15AVEB Руководство по установке
- Daikin FWXV15AVEB Приложение к руководству для дополнительного оборудования
- Daikin FWXV15AVEB Инструкция по эксплуатации
- Daikin FWXV20AVEB Инструкция по монтажу
- Daikin FWXV20AVEB Руководство по установке
- Daikin FWXV20AVEB Приложение к руководству для дополнительного оборудования
- Daikin FWXV20AVEB Инструкция по эксплуатации
- Daikin MC55WVM Инструкция по эксплуатации
- Daikin MC70LVM Инструкция по эксплуатации
- Daikin MCK55WVM Инструкция по эксплуатации