1 ■English
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING ....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .....Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
•
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and
use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal
pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and
insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
•
Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
01_EN_3P254362-9K.fm Page 1 Tuesday, October 30, 2012 7:31 PM
Содержание
- Installation manual 1
- Models rxs50k2v1b rxs60f4v1b rxg50k3v1b rx50g3v1b rx60g3v1b arxs50g3v1b 1
- R410a split series 1
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Low voltage 2006 95 ec machinery 2006 42 ec electromagnetic compatibility 2004 108 ec 2
- P291651 7d_offset book page 1 sunday july 8 2012 3 14 pm 2
- P327445 8b 2
- Rxg50k3v1b rxs50k2v1b rxs60f4v1b rx50g3v1b rx60g3v1b arxs50g3v1b 2
- Takayuki fujii managing director 1st of nov 2012 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- English 2 4
- Precautions for selecting the location 4
- The temperature of refrigerant circuit will be high please keep the inter unit wire away from copper pipes that are not thermally insulated this appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons sound pressure level is less than 70 db a 4
- Allow 300mm of work space below the ceiling surface 5
- Caution 5
- English 5
- Outdoor unit installation drawings 5
- Service lid 5
- Unit mm 5
- Drain work 6
- English 4 6
- Installation guidelines 6
- Installing outdoor unit 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- English 6 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- English 8 10
- Forced cooling operation 10
- Ftxs50k2v1b 10
- In order to protect the environment be sure to pump down when relocating or disposing of the unit 10
- Pump down operation 10
- Standby electricity saving 10
- The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into standby electricity saving mode thus reducing the power consumption of the air conditioner the standby electricity saving function works on the following indoor unit 10
- Caution 11
- English 11
- Facility setting cooling at low outdoor temperature 11
- This function is designed for facilities such as equipment or computer rooms it is never to be used in a residence or office where people occupy the space 11
- Warning 11
- Wiring 11
- Caution 12
- English 10 12
- Good wrong 12
- Good wrong stripping wire at terminal block 12
- Wiring diagram 12
- English 13
- Test items 13
- Trial operation and testing 13
- Wiring 13
- P254362 9k m12b166 14
Похожие устройства
- Daikin RX60G3V1B Инструкция по монтажу
- BRAIT BR395P PRO Инструкция по эксплуатации
- BRAIT BR395PС PRO Инструкция по эксплуатации
- Daikin RX71GV1B9 Инструкция по монтажу
- BRAIT BR395PE PRO Инструкция по эксплуатации
- BRAIT BR421P PRO Инструкция по эксплуатации
- Daikin RX71GV1B8 Инструкция по монтажу
- BRAIT BR421PE PRO Инструкция по эксплуатации
- BRAIT BR421P(7A) PRO Инструкция по эксплуатации
- BRAIT BR445P PRO Инструкция по эксплуатации
- BRAIT BR445PЕ PRO Инструкция по эксплуатации
- BRAIT BR445P(7А) PRO Инструкция по эксплуатации
- BRAIT BR445PЕ(7А) PRO Инструкция по эксплуатации
- BRAIT BR465P PRO Инструкция по эксплуатации
- BRAIT BR465PЕ PRO Инструкция по эксплуатации
- BRAIT BR750PE20A PRO Инструкция по эксплуатации
- BRAIT BR690PE20A PRO Инструкция по эксплуатации
- Daikin RX60G4V1B Инструкция по монтажу
- Daikin RX20K5V1B9 Инструкция по монтажу
- Daikin RX20K5V1B Инструкция по монтажу