Daikin RXLS25M2V1B [7/18] Outdoor unit installation drawings
![Daikin RXL35M2V1B [7/18] Outdoor unit installation drawings](/views2/1772921/page7/bg7.png)
■English 3
English
Outdoor Unit
Installation Drawings
**
*
(Foot bolt-hole
centres)
311
574
(Foot bolt-hole centres)
(From unit’s side)
105.5
O.D. 9.5mm
Gas pipe
Liquid pipe
O.D. 6.4mm
20g/m
15m
20m
Max. allowable piping
length
Max. allowable piping
height
Additional refrigerant
required for refrigerant
pipe exceeding
10m in length.
1.5m
Min. allowable piping
length
Wrap the insulation pipe with
the finishing tape from bottom
to top.
In sites with poor drainage, use
block bases for outdoor unit.
Adjust foot height until the unit
is leveled. Otherwise, water
leakage or pooling of water may
occur.
Where there is a danger of the unit
falling, use foot bolts, or wires.
250mm from wall
unit: mm
How to remove the stop
valve cover
Remove the screw on the
stop valve cover.
Slide the cover downward
to remove it.
How to attach the stop
valve cover
Insert the upper part of
the stop valve cover into the
outdoor unit.
Tighten the screws.
Stop valve cover
Allow space for piping
and electrical servicing.
*
Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced performance.
**
The suggested shortest pipe length is 1.5m, in order to avoid
noise from the outdoor unit and vibration.
(Mechanical noise and vibration may occur depending on how
the unit is installed and the environment in which it is used.)
Allow 300mm of
work space below
the ceilling surface
CAUTION
**Set the piping length
from 1.5m to 20m.
3P377531-1A.book Page 3 Monday, September 8, 2014 1:01 PM
Содержание
- Installation manual 1
- Outdoor unit 1
- Daikin industries czech republic s r o 3
- Electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 3
- En60335 2 4 3
- P377531 1a book page 1 monday september 8 2014 1 01 pm 3
- P378671 2c 3
- Rxlg25m2v1b rxlg35m2v1b rxl25m3v1b rxl35m3v1b 3
- Takayuki fujii managing director pilsen 1st of oct 2014 3
- Daikin industries czech republic s r o 4
- Electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 4
- En60335 2 4 4
- P377531 1a book page 1 monday september 8 2014 1 01 pm 4
- P378671 1a 4
- Rxls25m2v1b rxls35m2v1b rxl25m2v1b rxl35m2v1b arxl25m2v1b arxl35m2v1b 4
- Takayuki fujii managing director pilsen 1st of aug 2014 4
- Caution 5
- English 1 5
- Safety precautions 5
- Warning 5
- Accessories 6
- Accessories supplied with the outdoor unit 6
- Caution 6
- English 6
- Precautions for selecting the location 6
- Caution 7
- English 3 7
- Outdoor unit installation drawings 7
- Installation guidelines 8
- Installing outdoor unit 8
- Outdoor unit installation 8
- Precautions on installation 8
- Caution 9
- Flaring the pipe end 9
- Outdoor unit installation 9
- Refrigerant piping 9
- Warning 9
- Outdoor unit installation 10
- Purging air and checking gas leakage 10
- Warning 10
- Filling a cylinder with an attached siphon 11
- Filling other cylinders 11
- Outdoor unit installation 11
- Refilling the refrigerant 11
- Refrigerant piping work 11
- Stand the cylinder upright when filling 11
- There is a siphon pipe inside so the cylinder need not be upside down to fill with liquid 11
- Turn the cylinder upside down when filling 11
- Caution 12
- English 12
- How to force cooling operation mode 12
- Pump down operation 12
- Caution 13
- English 9 13
- Good wrong 13
- Warning 13
- Wiring 13
- English 14
- Wiring 14
- Wiring diagram 14
- Wiring diagram parts table 14
- Test items 15
- Test run and final check 15
- Trial operation and testing 15
Похожие устройства
- Daikin RXLS35M2V1B Руководство по монтажу
- Daikin ARXL25M2V1B Руководство по монтажу
- Daikin ARXL35M2V1B Руководство по монтажу
- Daikin RXLG50L2V1B Руководство по монтажу
- Daikin RXLG25L2V1B Руководство по монтажу
- Daikin RXLG35L2V1B Руководство по монтажу
- Daikin RXP50L2V1B Справочное руководство для монтажника
- Daikin RXP60L2V1B Справочное руководство для монтажника
- Daikin RXP71L2V1B Справочное руководство для монтажника
- Daikin RXJ50N2V1B Справочное руководство для монтажника
- Daikin RXA42B2V1B Справочное руководство для монтажника
- Daikin RXA50B2V1B Справочное руководство для монтажника
- Daikin RXM71N2V1B Справочное руководство для монтажника
- Daikin RXP50M2V1B Справочное руководство для монтажника
- Daikin RXP60M2V1B Справочное руководство для монтажника
- Daikin RXP71M2V1B Справочное руководство для монтажника
- Daikin RRDQ220V1 Инструкция по эксплуатации
- Panasonic CQ-VD6505W Инструкция по эксплуатации
- Daikin EWWS320DZXSA1 Инструкция по эксплуатации
- Daikin EWWS320DZXSA1 Руководство по монтажу