Daikin RXH20CAVMB [6/20] Electrical data
![Daikin RXH20CAVMB [6/20] Electrical data](/views2/1774367/page6/bg6.png)
3
• Split Sky Air • Outdoor Units
5
• Outdoor Units • R-410A • RXH-CAVMB
3 Electrical data
RXH20CVMB
Indoor unit Outdoor unit
Power supply Compressor OFM IFM
Hz-Volts
Voltage range
MCA MFA RHz RLA W FLA W FLA
FTXS20CVMB RXH20CVMB 50-230
MAX. 50Hz 253V
MIN. 50Hz 207V
14.0 15 42 2.81 25 0.35 18 0.20
3D044323
SYMBOLS
MCA : Min. Circuit Amps (A)
MFA : Max. Fuse Amps (A)
RHz : Rated operating frequency(Hz)
RLA : Rated Load Amps (A)
OFM : Outdoor Fan Motor
IFM : Indoor Fan Motor
FLA : Full Load Amps
W : Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
RXH25CVMB
Indoor unit Outdoor unit
Power supply Compressor OFM IFM
Hz-Volts
Voltage range
MCA MFA RHz RLA W FLA W FLA
FTXS25CVMB RXH25CVMB 50-230
MAX. 50Hz 253V
MIN. 50Hz 207V
14.0 15 47 3.21 25 0.35 18 0.20
3D044324
SYMBOLS
MCA : Min. Circuit Amps (A)
MFA : Max. Fuse Amps (A)
RHz : Rated operating frequency(Hz)
RLA : Rated Load Amps (A)
OFM : Outdoor Fan Motor
IFM : Indoor Fan Motor
FLA : Full Load Amps
W : Rated motor output (W)
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.0°CWB
Outdoor temp. : 35°CDB
2. Maximum allowable voltage unbalance between phases is 2%
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
Содержание
- Air conditioning systems 1
- Split sky air 1
- Technical data 1
- Capacity table 2
- Centre of gravity 2
- Cooling heating capacity tables 2
- Dimensional drawing 2
- Dimensional drawing centre of gravit 2
- Electrical dat 2
- Electrical specifications 2
- Feature 2
- Installatio 2
- Installation method 2
- Nominal capacity and nominal input 2
- Operation rang 2
- Option 2
- Piping diagra 2
- Sound dat 2
- Sound level data 2
- Sound pressure spectrum 2
- Specification 2
- Table of contents rxh cavmb 2
- Technical specifications 2
- Wiring diagra 2
- Wiring diagram 2
- Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall 3
- Features 3
- Outdoor units are fitted with a swing compressor renowned for its low noise and high energy efficiency 3
- Outdoor units for pair application 3
- Outdoor units r 410a rxh cavmb 3
- Split sky air outdoor units 2 3
- 1 nominal capacity and nominal input 4
- 2 technical specifications 4
- Specifications 4
- 2 technical specifications 5
- 3 electrical specifications 5
- Outdoor units r 410a rxh cavmb 5
- Specifications 5
- Split sky air outdoor units 4 5
- Electrical data 6
- Notes 1 rla is based on the following conditions indoor temp 27 cdb 19 cwb outdoor temp 35 cdb 2 maximum allowable voltage unbalance between phases is 2 3 select wire size based on the larger value of mca 4 instead of fuse use circuit breaker 5 for more details concerning conditional connections see http extranet daikineurope com select e data books finally click on the document title of your choice 6
- Outdoor units r 410a rxh cavmb 6
- Split sky air outdoor units 5 6
- Symbols mca min circuit amps a mfa max fuse amps a rhz rated operating frequency hz rla rated load amps a ofm outdoor fan motor ifm indoor fan motor fla full load amps w rated motor output w 6
- Electrical data 7
- Notes 1 rla is based on the following conditions indoor temp 27 cdb 19 cwb outdoor temp 35 cdb 2 maximum allowable voltage unbalance between phases is 2 3 select wire size based on the larger value of mca 4 instead of fuse use circuit breaker 5 for more details concerning conditional connections see http extranet daikineurope com select e data books finally click on the document title of your choice 7
- Outdoor units r 410a rxh cavmb 7
- Split sky air outdoor units 6 7
- Symbols mca min circuit amps a mfa max fuse amps a rhz rated operating frequency hz rla rated load amps a ofm outdoor fan motor ifm indoor fan motor fla full load amps w rated motor output w 7
- Options 8
- Outdoor units r 410a rxh cavmb 8
- Split sky air outdoor units 7 8
- 1 cooling heating capacity tables 9
- Capacity tables 9
- Outdoor units r 410a rxh cavmb 9
- Split sky air outdoor units 8 9
- 1 cooling heating capacity tables 10
- Capacity tables 10
- Outdoor units r 410a rxh cavmb 10
- Split sky air outdoor units 9 10
- 1 cooling heating capacity tables 11
- Capacity tables 11
- Outdoor units r 410a rxh cavmb 11
- Split sky air outdoor units 10 11
- 1 dimensional drawing 12
- Dimensional drawing centre of gravity 12
- Rxh20 25 35c 12
- 2 centre of gravity 13
- Dimensional drawing centre of gravity 13
- Rxh20 25c 13
- Rxh35c 13
- Outdoor units r 410a rxh cavmb 14
- Piping diagram 14
- Rxh20 25c 14
- Rxh35c 14
- Split sky air outdoor units 13 14
- 1 wiring diagram 15
- Rxh20 25 35c 15
- Wiring diagram 15
- 1 sound level data 16
- Outdoor units r 410a rxh cavmb 16
- Sound data 16
- Split sky air outdoor units 15 16
- 2 sound pressure spectrum 17
- Outdoor units r 410a rxh cavmb 17
- Sound data 17
- Split sky air outdoor units 16 17
- 1 installation method 18
- Installation 18
- Outdoor unit installation drawings 18
- Operation range 19
- Outdoor units r 410a rxh cavmb 19
- Rxh20 25 35c 19
- Split sky air outdoor units 18 19
- Eede06 1 3 05 2006 prepared in belgium by lannoo 20
- Split sky air 20
- Zandvoordestraat 300 b 8400 ostend belgium www daikineurope com 20
- Éeede06 1 3çëí 20
Похожие устройства
- Daikin RXH20CAVMB Сервис мануал
- Daikin RXH25CAVMB Технические данные
- Daikin RXH25CAVMB Сервис мануал
- Daikin RXH35CAVMB Технические данные
- Daikin RXH35CAVMB Сервис мануал
- АМАТЕК AC-IDV503VA Инструкции по подключению IP камеры к регистратору
- АМАТЕК AC-IDV503VA Углы обзора IP камер Amatek
- АМАТЕК AC-IDV503VA Подключение по протоколу RTSP
- АМАТЕК AC-IDV503VA Паспорт
- АМАТЕК AC-IDV503VA Приложение для мобильного наблюдения BitVision
- АМАТЕК AC-IDV503VA Руководство пользователя
- АМАТЕК AC-IDV503ZA Рекомендованные microSD карты памяти
- АМАТЕК AC-IDV503ZA Инструкции по подключению IP камеры к регистратору
- АМАТЕК AC-IDV503ZA Подключение по протоколу RTSP
- АМАТЕК AC-IDV503ZA Паспорт
- АМАТЕК AC-IDV503ZA Приложение для мобильного наблюдения BitVision
- АМАТЕК AC-IDV503ZA Руководство пользователя
- АМАТЕК AC-IDV503ZA Углы обзора IP камер Amatek
- АМАТЕК AC-IS501PTZ10 Углы обзора IP камер Amatek
- АМАТЕК AC-IS501PTZ10 Рекомендованные microSD карты памяти