Daikin ARX20JV1B [5/18] Specifications
![Daikin ARX35JV1B [5/18] Specifications](/views2/1775615/page5/bg5.png)
• Split Sky Air • Outdoor Units
3
• Outdoor Units • R-410A • ARX-JV1B
2 Specifications
2-1 Nominal capacity and nominal input ARX20JV1B ARX25JV1B ARX35JV1B
For combination
indoor units +
outdoor units
Indoor Units ATX20JV1B ATX25JV1B ATX35JV1B
Cooling capacity Min. kW 1.3
Btu/h 4,400
Kcal/h 1,120
Nom. kW 2.0 2.5 3.3
Btu/h 6,800 8,500 11,300
Kcal/h 1,720 2,150 2,840
Max. kW 2.6 3.0 3.8
Btu/h 8,900 10,200 13,000
Kcal/h 2,240 2,580 3,270
Heating capacity Min. kW 1.3
Btu/h 4,400
Kcal/h 1,120
Nom. kW 2.5 2.8 3.5
Btu/h 8,500 9,600 11,900
Kcal/h 2,150 2,410 3,010
Max. kW 3.5 4.0 4.8
Btu/h 11,600 13,600 16,400
Kcal/h 3,010 3,440 4,130
Piping connections Drain OD mm 18.0
Gas OD mm 9.52
Heat insulation Both liquid and gas pipes
Liquid OD mm 6.35
Power Input Cooling Min. kW 0.310 0.310 0.290
Nom. kW 0.550 0.730 0.980
Max. kW 0.720 1.050 1.300
Heating Min. kW 0.250 0.250 0.290
Nom. kW 0.950 0.690 0.930
Max. kW 0.950 1.110 1.290
For combination
indoor units +
outdoor units
EER Nominal 3.64 3.42 3.37
COP Nominal 4.24 4.06 3.76
Energy Label Cooling A
Heating A
Annual energy consumption kWh 275 365 490
Notes
Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
SL: The silent fan level of the air flow rate setting
2-2 TECHNICAL SPECIFICATIONS ARX20JV ARX25JV ARX35JV
Casing Colour Ivory white
Dimensions Unit Height mm 550
Width mm 658
Depth mm 275
Packing Height mm 616
Width mm 788
Depth mm 359
Weight Unit kg 28 30
Packed Unit kg 31 34
Heat Exchanger Dimensions Length mm 670 647
Nr of Rows 1 2
Fin Pitch mm 1.4
Nr of Stages 24
Tube type ø7 Hi-XA
Fin Type Waffle fin
Содержание
- Air conditioning systems 1
- Technical data 1
- Air conditioning systems 2
- Technical data 2
- Capacity table 3
- Centre of gravity 3
- Cooling heating capacity tables 3
- Dimensional drawing 3
- Dimensional drawing centre of gravit 3
- Electrical dat 3
- Electrical specifications 3
- Feature 3
- Nominal capacity and nominal input 3
- Operation rang 3
- Piping diagra 3
- Sound dat 3
- Sound pressure spectrum 3
- Specification 3
- Table of contents arx jv1b 3
- Technical specifications 3
- Wiring diagra 3
- Wiring diagram 3
- Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall 4
- Features 4
- Outdoor units are fitted with a swing compressor renowned for its low noise and high energy efficiency 4
- Outdoor units for pair application 4
- Outdoor units r 410a arx jv1b 4
- Split sky air outdoor units 2 4
- 1 nominal capacity and nominal input 5
- 2 technical specifications 5
- Outdoor units r 410a arx jv1b 5
- Specifications 5
- Split sky air outdoor units 3 5
- 2 technical specifications 6
- 3 electrical specifications 6
- Outdoor units r 410a arx jv1b 6
- Specifications 6
- Split sky air outdoor units 4 6
- Electrical data 7
- Outdoor units r 410a arx jv1b 7
- Split sky air outdoor units 5 7
- 1 cooling heating capacity tables 8
- Capacity tables 8
- Outdoor units r 410a arx jv1b 8
- Split sky air outdoor units 6 8
- 1 cooling heating capacity tables 9
- Capacity tables 9
- Outdoor units r 410a arx jv1b 9
- Split sky air outdoor units 7 9
- 1 cooling heating capacity tables 10
- Capacity tables 10
- Outdoor units r 410a arx jv1b 10
- Split sky air outdoor units 8 10
- 1 dimensional drawing 11
- Dimensional drawing centre of gravity 11
- Outdoor units r 410a arx jv1b 11
- Split sky air outdoor units 9 11
- 2 centre of gravity 12
- Dimensional drawing centre of gravity 12
- Outdoor units r 410a arx jv1b 12
- Split sky air outdoor units 10 12
- Outdoor units r 410a arx jv1b 13
- Piping diagram 13
- Split sky air outdoor units 11 13
- 1 wiring diagram 14
- Outdoor units r 410a arx jv1b 14
- Split sky air outdoor units 12 14
- Wiring diagram 14
- 1 sound pressure spectrum 15
- Outdoor units r 410a arx jv1b 15
- Sound data 15
- Split sky air outdoor units 13 15
- 1 sound pressure spectrum 16
- Outdoor units r 410a arx jv1b 16
- Sound data 16
- Split sky air outdoor units 14 16
- Operation range 17
- Outdoor units r 410a arx jv1b 17
- Split sky air outdoor units 15 17
- Naamloze vennootschap zandvoordestraat 300 b 8400 oostende belgium www daikin eu be 0412 120 336 rpr oostende 18
Похожие устройства
- Daikin ARX20JV1B Инструкция по монтажу
- Daikin ARX25JV1B Технические данные
- Daikin ARX25JV1B Инструкция по монтажу
- Daikin ARX35JV1B Технические данные
- Daikin ARX35JV1B Инструкция по монтажу
- Daikin ARX20JV1B Сервис мануал
- Daikin ARX25JV1B Сервис мануал
- Daikin ARX35JV1B Сервис мануал
- Daikin ARX20GV1B Инструкция по монтажу
- Daikin ARX20GV1B Сервис мануал
- Daikin ARX25GV1B Инструкция по монтажу
- Daikin ARX25GV1B Сервис мануал
- Daikin ARX35GV1B Инструкция по монтажу
- Daikin ARX35GV1B Сервис мануал
- Daikin FTK20GV1B Технические данные
- Daikin FTK20GV1B Сервис мануал
- Daikin FTK25GV1B Технические данные
- Daikin FTK25GV1B Сервис мануал
- Daikin FTK35GV1B Технические данные
- Daikin FTK35GV1B Сервис мануал