Daikin CDKS25CVMA [7/26] Remote controller
![Daikin CDXS25CVMA [7/26] Remote controller](/views2/1777800/page7/bg7.png)
6
■ Remote Controller
1. Signal transmitter:
•
It sends signals to the indoor unit.
2. Display:
• It displays the current settings.
(In this illustration, each section is shown
with all its displays ON for the purpose of
explanation.)
3. HOME LEAVE button:
HOME LEAVE operation (page 14.)
4. POWERFUL button:
POWERFUL operation (page 12.)
5. TEMPERATURE adjustment buttons:
• It changes the temperature setting.
6. ON/OFF button:
• Press this button once to start operation.
Press once again to stop it.
7. MODE selector button:
• It selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN) (page 10.)
8. SILENT button: OUTDOOR UNIT
SILENT operation (page 13.)
9. FAN setting button:
• It selects the air flow rate setting.
10. ON TIMER button: (page 17.)
11. OFF TIMER button: (page 16.)
12. TIMER Setting button:
• It changes the time setting.
13. TIMER CANCEL button:
• It cancels the timer setting.
14. CLOCK button: (page 9.)
15. RESET button:
• Restart the unit if it freezes.
• Use a thin object to push.
1
2
5
6
9
13
15
14
10
12
11
〈 ARC433A69, 76 〉
3
4
7
8
Содержание
- Daikin room air conditioner 1
- Models 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- Indoor unit 5
- Names of parts 5
- Outdoor unit 6
- Arc433a69 76 7
- Remote controller 7
- Attention 8
- Preparation before operation 8
- To set the batteries 8
- Attention 9
- Preparation before operation 9
- To fix the remote controller holder on the wall 9
- To operate the remote controller 9
- Be careful not to cool heat the room too much keeping the temperature setting at a moderate level helps save energy 10
- Clogged air filters cause inefficient operation and waste energy clean them once in about every two weeks 10
- Condensation may occur on the indoor unit and drip 10
- Cover windows with a blind or a curtain blocking sunlight and air from outdoors increases the cooling heating effect 10
- If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off 10
- Operation outside this humidity or temperature range may cause a safety device to disable the system 10
- Outdoor temperature 10 to 46 c indoor temperature 18 to 32 c indoor humidity 80 max 10
- Outdoor temperature 15 to 15 c indoor temperature 10 to 30 c 10
- Recommended temperature setting 10
- The air conditioner always consumes 15 35 watts of electricity even while it is not operating 10
- To set the clock 10
- Turn the breaker on 10
- Use the air conditioner in the following conditions 10
- Auto dry cool heat fan operation 11
- To change the temperature setting 11
- To start operation 11
- To stop operation 11
- Press fan setting button 12
- To change the air flow rate setting 12
- Powerful operation 13
- To cancel powerful operation 13
- To start powerful operation 13
- Outdoor unit silent operation 14
- To cancel outdoor unit silent operation 14
- To start outdoor unit silent operation 14
- Before using home leave operation 15
- Home leave operation 15
- To cancel home leave operation 15
- To start home leave operation 15
- Use as a favorite mode 16
- Use as an energy saving mode 16
- Useful in these cases 16
- What s the home leave operation 16
- Timer operation 17
- To cancel the off timer operation 17
- To use off timer operation 17
- After a breaker has turned off after a power failure after replacing batteries in the remote controller 18
- Attention 18
- In the following cases set the timer again 18
- The timer lamp goes off 18
- To cancel on timer operation 18
- To combine on timer and off timer 18
- To use on timer operation 18
- Caution 19
- Night quiet mode available only for cooling operation 19
- Note for multi system 19
- Outdoor unit silent operatio 19
- Page 13 19
- See priority room setting on the next page 19
- Selecting the operation mode 19
- What is a multi system 19
- Example room a is the priority room in the examples 20
- Operation mode priority 20
- Priority room setting 20
- Priority when powerful operation is used 20
- Priority when using outdoor unit silent operation 20
- The priority room setting requires initial programming during installation please consult your retailer or dealer for assistance 20
- Before cleaning be sure to stop the operation and turn the breaker off 21
- Care and cleaning 21
- Caution 21
- Cleaning the air filter 21
- Only a qualified service person is allowed to perform maintenance 21
- Removing the air filter 21
- Replacing the air filter 21
- After operation stops turn off the breaker for the room air conditioner 22
- Before a long idle period 22
- Caution 22
- Clean the air filters and set them again 22
- Cleaning the drain pan 22
- Take out batteries from the remote controller 22
- Case explanation 23
- These cases are not troubles 23
- Trouble shooting 23
- Case check 24
- Check again 24
- Call the service shop immediately 25
- Disposal requirements 25
- Warning 25
- We recommend periodical maintenance 25
- P141308 7h m06b022 26
Похожие устройства
- Daikin CDKS25CVMA Сервис мануал
- Daikin CDKS35CVMA Инструкция по эксплуатации
- Daikin CDKS35CVMA Сервис мануал
- Daikin CDKS50CVMA Инструкция по эксплуатации
- Daikin CDKS50CVMA Сервис мануал
- Daikin CDKS60CVMA Инструкция по эксплуатации
- Daikin CDKS60CVMA Сервис мануал
- Daikin CDXS25EAVMT Сервис мануал
- Daikin CDXS35EAVMT Сервис мануал
- Daikin CDXS25EAVMA Сервис мануал
- Daikin CDXS35EAVMA Сервис мануал
- Daikin CDXS35EAVMA Инструкция по эксплуатации
- Daikin CDXS25EAVMA Инструкция по эксплуатации
- Daikin CDKS25EAVMA Инструкция по эксплуатации
- Daikin CDKS25EAVMA Сервис мануал
- Daikin CDKS35EAVMA Инструкция по эксплуатации
- Daikin CDKS35EAVMA Сервис мануал
- Daikin FTKS20DVMA Сервис мануал
- Daikin FTKS25DVMA Сервис мануал
- Daikin FTKS35DVMA Сервис мануал