Daikin CDKS35EAVMA [4/26] Consider nuisance to your neighbours from noises
![Daikin CDKS35EAVMA [4/26] Consider nuisance to your neighbours from noises](/views2/1777835/page4/bg4.png)
3
•
Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard.
•
Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions,
moisture in the air may condense and drip.
•
After a long use, check the unit stand and fittings for damage.
•
Do not touch the air inlet and alminum fins of outdoor unit. It may cause injury.
•
The appliance is not intended for use by young children or infirm persons without supervision.
•
Young children should be supervised to ensure that they do not play with the appliance.
•
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the
air conditioner.
•
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord.
•
Do not connect the air conditioner to a power supply different from the one as specified. It may cause trou-
ble or fire.
•
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may
result in electric shocks.
•
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the building, furniture
etc.
•
Do not place things that must be kept dry under the indoor unit. Water may drip from the indoor unit if the humidity is
80% or above or when the drain outlet is clogged or the air-filter is dirtied.
•
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around
the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunc-
tions, smoke or fire when making contact with electrical parts.
•
Do not operate the air conditioner with wet hands.
•
Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
•
Do not place things such as vessels containing water or anything else on top of the unit. Water may pene-
trate into the unit and degrade electrical insulations, resulting in an electric shock.
■
To install the air conditioner in the following types of environments, consult the dealer.
•
Places with an oily ambient or where steam or soot occurs.
•
Salty environment such as coastal areas.
•
Places where sulfide gas occurs such as hot springs.
•
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.
■ For installation, choose a place as described below.
•
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
•
A place from where the air discharged from the outdoor unit or the operation noise will not annoy
your neighbours
.
•
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
•
Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if reloca-
tion is necessary for moving or remodeling.
Installation site.
Consider nuisance to your neighbours from noises.
Electrical work.
System relocation.
01_EN_3P141308-6E.fm Page 3 Monday, December 5, 2005 1:39 PM
Содержание
- Daikin room air conditioner 1
- Models 1
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- I indoor unit 5
- Names of parts 5
- I outdoor unit 6
- I remote controller 7
- Attention 8
- I to set the batteries 8
- Preparation before operation 8
- Attention 9
- Choose a place from where the sig nals reach the unit 9
- Fix the holder to a wall a pillar etc with the screws supplied with the holder 9
- I to fix the remote controller holder on the wall 9
- I to operate the remote controller 9
- Place the remote controller in the remote controller holder 9
- Preparation before operation 9
- I to set the clock 10
- I turn the breaker on 10
- Press clock button 10
- Press timer setting button to set the clock to the present time 10
- Auto dry cool heat fan operation 11
- I to change the temperature setting 11
- I to start operation 11
- I to stop operation 11
- Press mode selector button and select a operation mode 11
- Press on off button 11
- Press on off button again 11
- Press temperature adjustment button 11
- I to change the air flow rate setting 12
- Press fan setting button 12
- I to cancel powerful operation 13
- I to start powerful operation 13
- Powerful operation 13
- I to start outdoor unit silent operation 14
- Outdoor unit silent operation 14
- To cancel outdoor unit silent operation 14
- Before using home leave operation 15
- Home leave operation 15
- I to cancel home leave operation 15
- I to start home leave operation 15
- Disengaging home leave opera tion will return the temperature to that set for normal operation even the coldest winters will pose no problem 16
- I useful in these cases 16
- I what s the home leave operation 16
- Use as a favorite mode 16
- Use as an energy saving mode 16
- I to cancel the off timer operation 17
- Timer operation 17
- To use off timer operation 17
- Attention 18
- I to cancel on timer operation 18
- I to combine on timer and off timer 18
- I to use on timer operation 18
- Press cancel button 18
- Press on timer button 18
- Press on timer button again 18
- Press timer setting button until the time setting reaches the point you like 18
- Night quiet mode available only for cooling operation 19
- Note for multi system 19
- Outdoor unit silent operatio 19
- Selecting the operation mode 19
- Example room a is the priority room in the examples 20
- I priority room setting 20
- Operation mode priority 20
- Priority when powerful operation is used 20
- Priority when using outdoor unit silent operation 20
- The priority room setting requires initial programming during installation please consult your retailer or dealer for assistance 20
- Attach the filter to the main unit while pushing down on the bends 21
- Before cleaning be sure to stop the operation and turn the breaker off 21
- Care and cleaning 21
- Caution 21
- Cleaning the air filter 21
- Filter 21
- I cleaning the air filter 21
- In case of back side in case of bottom side 21
- Main unit 21
- Only a qualified service person is allowed to perform maintenance 21
- Removing the air filter 21
- Replacing the air filter 21
- After operation stops turn off the breaker for the room air conditioner 22
- Caution 22
- Clean the air filters and set them again 22
- I before a long idle period 22
- I cleaning the drain pan 22
- Operate the fan only for several hours on a fine day to dry out the inside 22
- Take out batteries from the remote controller 22
- Case explanation 23
- These cases are not troubles 23
- Trouble shooting 23
- Case check 24
- Check again 24
- Call the service shop immediately 25
- I the power cord is abnormally hot or damaged i an abnormal sound is heard during operation i the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently i a switch or a button often fails to work properly i there is a burning smell i water leaks from the indoor unit 25
- Turn the breaker off and call the service shop 25
- Warning 25
- We recommend periodical maintenance 25
Похожие устройства
- Daikin CDKS35EAVMA Сервис мануал
- Daikin FTKS20DVMA Сервис мануал
- Daikin FTKS25DVMA Сервис мануал
- Daikin FTKS35DVMA Сервис мануал
- Daikin FTXS20DVMA Сервис мануал
- Daikin FTXS25DVMA Сервис мануал
- Daikin FTXS35DVMA Сервис мануал
- Daikin FTKS25DVM Сервис мануал
- Daikin FTKS35DVM Сервис мануал
- Daikin FTXS20DVMT Сервис мануал
- Daikin FTXS25DVMT Сервис мануал
- Daikin FTXS35DVMT Сервис мануал
- Daikin FTXS50DVMT Сервис мануал
- Daikin FTXS60DVMT Сервис мануал
- Daikin FTXS71DVMT Сервис мануал
- Came FLUO-SLBE BASIC EMERGENCY, КОРОБ 4400 ММ Инструкция по эксплуатации
- Came FLUO-SLBE BASIC EMERGENCY, КОРОБ 4400 ММ Проектная документация
- Came FLUO-SLBE BASIC EMERGENCY, КОРОБ 4400 ММ Сертификат
- Came FLUO-SLBE BASIC EMERGENCY, КОРОБ 4400 ММ Каталог
- Came FLUO-SLE STANDARD EMERGENCY, КОРОБ 2600 ММ Инструкция по эксплуатации