Daikin CDKS35BVMB [2/11] Safety precautions
![Daikin CDKS35BVMB [2/11] Safety precautions](/views2/1778716/page2/bg2.png)
1
●
Read these SAFETY PRECAUTIONS carefully to ensure correct installation.
●
This manual classifies the precautions into WARNINGS and CAUTIONS.
Be sure to follow all the precautions below: they are all important for ensuring safety.
●
The following safety symbols are used throughout this manual:
●
After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
WARNINGS
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTIONS Failure to follow any of CAUTION may in some cases result in grave consequences.
SAFETY PRECAUTIONS
Never attempt.Be sure to observe this instruction.
Be sure to establish an earth
connection.
WARNINGS
●
Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
●
Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
●
Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
●
Install the air conditioner on a solid base that can support the units weight.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
●
Electrical work should be carried out in accordance with the installation manual and the national electrical
wiring rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
●
Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
●
For wiring, use a cable long enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
●
Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
●
After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue
force on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
●
When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other
than the specified refrigerant (R-410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
●
If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
●
After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
●
When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration
cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
●
Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock. A high surge current from lightning or other sources may cause damage to the air conditioner.
●
An earth leakage circuit breaker may be required depending on site condition to prevent electrical shock.
Failure to do so may cause electrical shock.
CAUTIONS
●
Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
●
Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
●
Note for installing the outdoor unit. (For heat pump model only.)
In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor unit’s drain may freeze.
If so, it is recommended to install an electric heater in order to protect drain from freezing.
●
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
Содержание
- Installation manual 1
- Models cdxs25bvmb cdks25bvmb cdxs35bvmb cdks35bvmb cdxs50bvmb cdks50bvmb cdxs60bvmb cdks60bvmb 1
- R 410a split series 1
- Cautions 2
- Safety precautions 2
- Warnings 2
- Accessories 3
- Before choosing the installation site obtain user approval 3
- Choosing a site 3
- I use suspension bolts to install the unit check whether or not the ceiling is strong enough to support the weight of the unit if there is a risk that the ceiling is not strong enough reinforce the ceiling before installing the unit i select the signal receiver mounting location within the signal receiver mounting area according to the following conditions 3
- Indoor unit 3
- Outdoor unit 3
- Wireless remote controller 3
- Chamber cap 4
- In case of bottom suction air 4
- Preparations before installation 4
- I mounting the signal receiver 5
- I temporarily install the indoor unit 5
- I tighten the top nuts 5
- I use a water level or water filled vinyl tubes to check that the unit is level at all four corners as shown in the drawing 5
- Indoor unit installation 5
- Install as described in the installation manual supplied with the multi outdoor unit 5
- Outdoor unit installation 5
- Vinyl tube 5
- Water level 5
- Flaring the pipe end 6
- Refrigerant piping 6
- Refrigerant piping work 6
- Cautions on pipe handling 7
- Refrigerant piping work 7
- Selection of copper pipes and heat insulation materials 7
- When using commercial copper pipes and fittings observe the following 7
- Drain work 8
- I connect the drain pipe as described below 8
- I pour some water into the drain pan to check that the water drains smoothly 8
- See the installation manual supplied with the multi outdoor unit for outdoor unit 8
- Warning 8
- Wiring 8
- Attach the filter to the main unit while pushing down on the tabs 9
- Care and cleaning 9
- Caution 9
- Filter 9
- I cleaning the air filter 9
- I cleaning the drain pan 9
- In case of bottom suction 9
- In case of rear suction 9
- Main unit 9
- For cooling only 10
- For heat pump 10
- Test items 10
- Trial operation and testing 10
- Trial operation from remote controller 10
Похожие устройства
- Daikin CDKS35BVMB Сервис мануал
- Daikin CDXS25BVMB Инструкция по монтажу
- Daikin CDXS25BVMB Сервис мануал
- Daikin CDXS35BVMB Инструкция по монтажу
- Daikin CDXS35BVMB Сервис мануал
- Daikin CDXS50BVMB Инструкция по монтажу
- Daikin CDXS50BVMB Технические данные
- Daikin CDXS50BVMB Сервис мануал
- Daikin CDXS60BVMB Инструкция по монтажу
- Daikin CDXS60BVMB Технические данные
- Daikin CDXS60BVMB Сервис мануал
- Daikin CDKS50BVMB Инструкция по монтажу
- Daikin CDKS50BVMB Технические данные
- Daikin CDKS50BVMB Сервис мануал
- Daikin CDKS60BVMB Инструкция по монтажу
- Daikin CDKS60BVMB Технические данные
- Daikin CDKS60BVMB Сервис мануал
- Daikin CDK25AVM Сервис мануал
- Daikin CDK35AVM Сервис мануал
- Daikin CDK50AVM Сервис мануал