Daikin CDXS60BVMB [9/11] Care and cleaning
![Daikin CDKS35BVMB [9/11] Care and cleaning](/views2/1778716/page9/bg9.png)
8
CARE AND CLEANING
CAUTION
●
Only a qualified service person is allowed to perform maintenance.
●
Before cleaning, be sure to stop the operation and turn the breaker OFF.
●
Remove the air filter when connecting the duct.
■ Cleaning the air filter.
1.Removing the air filter.
●
Rear suction
Pull the bottom side of the air filter backwards, over the 2 bends.
●
Bottom suction
Pull the filter over the two bends situated at the backside of the unit.
2.Cleaning the air filter.
Remove dust from the air filter using a vacuum cleaner and gently rinse them in cool
water. Do not use detergent or hot water to avoid filter shrinking or deformation. After
cleaning dry them in the shade.
3.Replacing the air filter.
●
Rear suction
Hook the filter behind the flap situated at the top of the unit and push the other side gently over the 2 bends.
●
Bottom suction
Hook the filter behind the flap situated at the middle of
the unit and push the other side gently over the 2
bends.
■ Cleaning the drain pan
●
Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage.
Ask your DAIKIN dealer to clean them.
●
If the ambient air of indoor unit is so dusty, install the optional Dust Cover which prevent dust from falling into drain pan.
CAUTION
●
Do not operate the air conditioner without filters, this to avoid dust accummulation inside the unit.
●
Do not remove the air filter except when cleaning.
Unnecessary handling may damage the filter.
●
Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide, It may cause discoloring or warping.
●
Do not let the indoor unit get wet. It may cause an electric shock or a fire.
●
Operation with dusty air filters lowers the cooling and heating capacity and wastes energy.
●
The suction grille is option.
●
Do not use water or air of 50°C or higher for cleaning air filters and outside panels.
In case of rear-suction.
Filter
Main unit
Attach the filter
to the main unit
while pushing
down on the
tabs.
In case of bottom-suction.
Содержание
- Installation manual 1
- Models cdxs25bvmb cdks25bvmb cdxs35bvmb cdks35bvmb cdxs50bvmb cdks50bvmb cdxs60bvmb cdks60bvmb 1
- R 410a split series 1
- Cautions 2
- Safety precautions 2
- Warnings 2
- Accessories 3
- Before choosing the installation site obtain user approval 3
- Choosing a site 3
- I use suspension bolts to install the unit check whether or not the ceiling is strong enough to support the weight of the unit if there is a risk that the ceiling is not strong enough reinforce the ceiling before installing the unit i select the signal receiver mounting location within the signal receiver mounting area according to the following conditions 3
- Indoor unit 3
- Outdoor unit 3
- Wireless remote controller 3
- Chamber cap 4
- In case of bottom suction air 4
- Preparations before installation 4
- I mounting the signal receiver 5
- I temporarily install the indoor unit 5
- I tighten the top nuts 5
- I use a water level or water filled vinyl tubes to check that the unit is level at all four corners as shown in the drawing 5
- Indoor unit installation 5
- Install as described in the installation manual supplied with the multi outdoor unit 5
- Outdoor unit installation 5
- Vinyl tube 5
- Water level 5
- Flaring the pipe end 6
- Refrigerant piping 6
- Refrigerant piping work 6
- Cautions on pipe handling 7
- Refrigerant piping work 7
- Selection of copper pipes and heat insulation materials 7
- When using commercial copper pipes and fittings observe the following 7
- Drain work 8
- I connect the drain pipe as described below 8
- I pour some water into the drain pan to check that the water drains smoothly 8
- See the installation manual supplied with the multi outdoor unit for outdoor unit 8
- Warning 8
- Wiring 8
- Attach the filter to the main unit while pushing down on the tabs 9
- Care and cleaning 9
- Caution 9
- Filter 9
- I cleaning the air filter 9
- I cleaning the drain pan 9
- In case of bottom suction 9
- In case of rear suction 9
- Main unit 9
- For cooling only 10
- For heat pump 10
- Test items 10
- Trial operation and testing 10
- Trial operation from remote controller 10
Похожие устройства
- Daikin CDXS60BVMB Технические данные
- Daikin CDXS60BVMB Сервис мануал
- Daikin CDKS50BVMB Инструкция по монтажу
- Daikin CDKS50BVMB Технические данные
- Daikin CDKS50BVMB Сервис мануал
- Daikin CDKS60BVMB Инструкция по монтажу
- Daikin CDKS60BVMB Технические данные
- Daikin CDKS60BVMB Сервис мануал
- Daikin CDK25AVM Сервис мануал
- Daikin CDK35AVM Сервис мануал
- Daikin CDK50AVM Сервис мануал
- Daikin CDK60AVM Сервис мануал
- Daikin CDK25AVMA Сервис мануал
- Daikin CDK25AVMA Технические данные
- Daikin CDK35AVMA Сервис мануал
- Daikin CDK35AVMA Технические данные
- Daikin CDK50AVMA Сервис мануал
- Daikin CDK50AVMA Технические данные
- Daikin CDK60AVMA Сервис мануал
- Daikin CDK60AVMA Технические данные