Ghibli POWER WD 36 P [19/72] Using the applicance

Ghibli POWER TOOL PRO FD 36 I COMBI [19/72] Using the applicance
www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
ENGLISH -
3
(15 Fig. 7) on the drum.
- To release the sleeve (14 Fig. 7) turn the
lever (16 Fig. 7) clockwise and then pull
the sleeve outwards (14 Fig. 7).
- Merge the ergonomic handle (17 Fig.
8) or hose (18 Fig. 8) depending on the
model, with the extension (19 Fig. 8).
- Connect the two rigid extensions (19-
20 Fig. 9) by aligning the two reference
points (21-22 Fig. 9).
- Mount on the rigid extension (20 Fig. 10)
the desired accessory,( vacuum nozzle,
floor nozzle etc..)
NOTES:
For models equipped with ergonomic handle
it is possible to adjust the suction force acting
the nut (23 Fig. 11).
By opening the little window (24 Fig. 11) you
get a lower suction force.
USING THE APPLICANCE
- The device is equipped with wheels and
thus can be moved with the proper han-
dles, or it can be pushed with the help of
the handle (26 Fig. 14).
- To lift it up insert your fingers under the
dedicated handle (27 Fig. 15) on the top
of the cover of the single version motor or
lift with the help of two people using the
handles (28 Fig. 14).
Starting the appliance as a dust
suction device or liquid suction
device
- Insert the plug (29 Fig.16) into the socket.
Single motor
- Push the switch (30 Fig. 17) on “I” to start
the suction motor; the switch lights up.
Double motor
- Depending on the power required it is
possible to start only one motor by press-
ing the switch (31 Fig. 17) on “I” or both
switches (31 e 32 Fig. 17) if a greater
suction force is required.
When the switch pressed the correspond-
ing button lights up.
NOTES:
When the recovery tank is full, the noise
intensity increases and the device can no
longer aspire. Then you must switch off the
device and empty the tank as described in
the relevant paragraphs.
Starting the appliance with tools
Manual start-up
- Position the switch (57 Fig. 18) at “MAN”
- Press the switch (53 Fig. 18) at “ON”,
which lights up; the vacuum cleaner
starts.
Automatic start-up
- Position the switch (57 Fig. 18) at “AUT”
- Press the switch (53 Fig. 18) at “ON”,
which lights up. The vacuum cleaner
starts-up when the tool connected starts
and stops a few seconds after tool switch-
off.
Filter-shaker
For machines supplied.
- Remove the suction hose as described in
the relative paragraph.
- Start the suction motor.
- Use one hand to block the suction nozzle
(15 Fig. 19) and use the other hand to
open the hatch (54 Fig. 19) for one - two
seconds.
- Repeat the procedure 3 times and then
switch the suction motor off.
Switching off the appliance
- Push the switches (30, 31, 32 Fig. 17)
to the “0” position to stop the device; the
lights, if any on the switches, will go off.
- Remove the plug (29 Fig. 16) from the
electrical socket.
- Wind up the cable (33 Fig. 20) and hook
it onto its housing (34 Fig. 20).
Manuale POWER LINE_8050814_1ed_01-2019.indd 3 27/02/19 09:31