Daikin ATKS35BVMB [9/14] _en_2p098777 1 fm page 8 friday october 18 2002 1 26 pm

Daikin ATX35BVMB [9/14] _en_2p098777 1 fm page 8 friday october 18 2002 1 26 pm
English 8
Note:
1) Wrap the refrigerant pipes and drain hose together with insulation tape as
right figure, in case of setting the drain hose through the back of the indoor
unit.
2) If it difficult to fix the claws of the bottom frame on the catches of the
mounting plate.
Secure indoor unit to the mounting plate with scres (M4 × 12L).
3-3. Wall Embedded Piping
Follow the instructions given under
1) Insert the drain hose to this depth so it wont be pulled out of the drain
pipe.
4.
Wiring.
, install as described in the installation manual supplied with the Multi outdoor unit.
1) Strip wire ends (15 mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corre-
sponding terminals.
3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) Shape the wires so that the service lid fits securely, then close service lid.
Warning
Do not use tapped wires, stand wires, extensioncords, or starbust connections, as they may cause overtheating, electrical
shock,or fire.
Left-Side, Left-Back, or Left Bottom Piping
Refrigerant
pipes
Drain hose
Bottom frame
H M4 × 12L (2 point)
Mounting
plate
A
Inner wall
Vinyl chloride
drain pipe
(VP-30)
Drain hose50 mm
or more
Insert drain hose
to this depth so
it won
t be pulled
out of drain pipe.
Outer wall
With a Multi indoor unit
123
Terminal block
Electrical component box
Wire retainer
Use the specified wire type.
Firmly secure wire retainer so that
wires sustain no external stress.
Shape wires so that the
service lid will fit securely.
1
2
3
123 LN
Safety
breaker
15A
Earth leakage
circuit breaker
Earth
When wire length exceeds
10 m, use 2.0-mm wires.
H05VV
Firmly fix the wires with
the terminal screws.
Outdoor unit
Indoor
unit
Power
supply
50Hz 220V - 240V
60Hz 220V - 230V
Firmly fix the wires with
the terminal screws.
01_EN_2P098777-1.fm Page 8 Friday, October 18, 2002 1:26 PM