Daikin ATK25BVMB [2/14] Cautions
![Daikin ATXS35BVMB [2/14] Cautions](/views2/1778712/page2/bg2.png)
1 ■English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNINGS and CAUTIONS.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNINGS
............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTIONS.............Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use and cleaning of the unit
according to the Operation Manual.
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
WARNINGS
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the unit’s weight.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable long enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause termi-
nal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R-410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks.
CAUTIONS
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Note for installing the outdoor unit. (For heat pump model only.)
In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor unit’s drain may freeze.
If so, it is recommended to install an electric heater in order to protect drain from freezing.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
01_EN_2P098777-1.fm Page 1 Friday, October 18, 2002 1:26 PM
Содержание
- Ftxs25bvmb ftks25bvmb ftxs35bvmb ftks35bvmb ftx25bvmb ftk25bvmb ftx35bvmb ftk35bvmb atxs25bvmb atks25bvmb atxs35bvmb atks35bvmb atx25bvmb atk25bvmb atx35bvmb atk35bvmb 1
- Installation manual 1
- Models 1
- R 410a split series 1
- Cautions 2
- I english 2
- Safety precautions 2
- Warnings 2
- Accessories 3
- Choosing a site 3
- How to remove the front grille 3
- I english 2 3
- Indoor unit 3
- Installation tips 3
- Wireless remote controller 3
- How to attach the front grille 4
- How to attach the front panel 4
- How to remove the front panel 4
- How to set te different addresses 4
- I english 4
- Installation tips 4
- Pcb in the indoor unit 4
- Wireless remote controller 4
- Ftx25 35 ftk25 35 atx25 35 atk25 35 5
- Ftxs25 35 ftks25 35 atxs25 35 atks25 35 5
- I english 4 5
- Indoor unit installation drawings 5
- Install air puriying filter on air filter 5
- Adjusting the angle 6
- Iiii caution 6
- Intelligent eye sensor 6
- Boring a wall hole and installing wall embedded pipe 7
- I english 6 7
- Indoor unit installation 7
- Installing the mounting plate 7
- 2 left side left back or left bottom piping 8
- Caulk this hole with putty or caulking material bind with plastic tape 8
- Do not apply lubricating oil refrigerant machine oil when inserting application of causes deterioration and drain leakage of the plug 8
- Drain hose 8
- I english 8
- Indoor unit installation 8
- Insert a hexagon wrench 4 mm 8
- Installing indoor unit 8
- No gap 8
- Wrap insulating tape around the bent portion of refrigerant pipe overlap at least half the width of the tape with each turn interconnecting wires 8
- _en_2p098777 1 fm page 7 friday october 18 2002 1 26 pm 8
- 3 wall embedded piping 9
- I english 8 9
- Iiii warning 9
- Wiring 9
- _en_2p098777 1 fm page 8 friday october 18 2002 1 26 pm 9
- Drain piping 10
- I english 10
- Indoor unit installation 10
- When connecting to an ha system 10
- Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas 11
- Cut the pipe end with a pipe cutter 2 remove burrs with the cut surface facing downward so that the chips do not enter the pipe 3 put the flare nut on the pipe 4 flare the pipe 5 check that the flaring is properly made 11
- Do not use mineral oil on flared part 2 prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 never use piping which has been used for previous installations only use parts which are delivered with the unit 4 do never install a drier to this r 410a unit in order to guarantee its lifetime 5 the drying material may dissolve and damage the system 6 incomplete flaring may cause refrigerant gas leakage 11
- Flaring the pipe end 11
- Iiii warning 11
- Protect the open end of the pipe against dust and moisture 2 all pipe bends should be as gentle as possible use a pipe bender for bending bending radius should be 30 to 40 mm or larger 11
- Refrigerant piping 11
- Refrigerant piping work 11
- To prevent gas leakage apply refrigeration machine oil on both inner and outer surfaces of the flare use refrigeration oil for r 410a 11
- 2 selection of copper and heat insulation materials 12
- I english 12
- Refrigerant piping work 12
- I english 12 13
- Test items 13
- Trial operation and testing 13
- Trial operation from remote controller 13
- P098777 1 m02b078 14
Похожие устройства
- Daikin ATK25BVMB Сервис мануал
- Daikin ATK35BVMB Инструкция по монтажу
- Daikin ATK35BVMB Сервис мануал
- Daikin FTS20BVMB Технические данные
- Daikin FTS20BVMB Инструкция по эксплуатации
- Daikin FTS20BVMB Сервис мануал
- Daikin FTS25BVMB Инструкция по эксплуатации
- Daikin FTS25BVMB Технические данные
- Daikin FTS25BVMB Сервис мануал
- Daikin FTS35BVMB Инструкция по эксплуатации
- Daikin FTS35BVMB Технические данные
- Daikin FTS35BVMB Сервис мануал
- Daikin FTYS20BVMB Инструкция по эксплуатации
- Daikin FTYS20BVMB Технические данные
- Daikin FTYS20BVMB Сервис мануал
- Daikin FTYS25BVMB Инструкция по эксплуатации
- Daikin FTYS25BVMB Технические данные
- Daikin FTYS25BVMB Сервис мануал
- Daikin FTYS35BVMB Инструкция по эксплуатации
- Daikin FTYS35BVMB Технические данные