Accessories
Accessories supplied with the outdoor unit:
Precautions for Selecting the Location
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbors of
the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent interference
to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient tempera-
ture, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its suction
side facing the wall.
2) Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the snow will not affect the unit.
(A) Installation Manual
1
(B) Drain plug (Heat pump-Models)
There is on the bottom packing case.
1
(C) Refrigerant charge label
1
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
01_EN_3P203824-5B.fm Page 2 Monday, March 31, 2008 1:09 PM
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Rxs20g2v1b rks20g2v1b rxs25g2v1b rks25g2v1b rxs35g2v1b rks35g2v1b rxg25e3v1b rxg35e3v1b arxs20g2v1b arxs25g2v1b arxs35g2v1b arxg25e3v1b arxg35e3v1b 1
- Daikin industries ltd 2
- Electromagnetic compatibility 2004 108 ec 2
- Low voltage 2006 95 ec 2
- Noboru murata manager quality control department shiga 1st of nov 2007 2
- Sb63850 9e 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- English 2 4
- Precautions for selecting the location 4
- Caution 5
- English 5
- Outdoor unit installation drawings 5
- Drain work heat pump models 6
- English 4 6
- Installation guidelines 6
- Installing outdoor unit 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- English 6 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- English 8 10
- Standby electricity saving 10
- The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into standby electricity saving mode thus educing the power consumption of the air conditioner 10
- Caution 11
- English 11
- Facility setting cooling at low outdoor temperature 11
- How to force cooling operation mode 11
- Pump down operation 11
- Caution 12
- English 10 12
- Good wrong 12
- Strip wire end to this point 12
- Warning 12
- Wiring 12
- _en_3p203824 5b fm page 10 monday march 31 2008 1 09 pm 12
- English 13
- Test items 13
- Test run and final check 13
- Trial operation and testing 13
- P203824 5b m07b117a 14
Похожие устройства
- Daikin RXG25E3V1B Инструкция по монтажу
- Daikin ARXG25E3V1B Инструкция по монтажу
- Daikin ARXG35E3V1B Инструкция по монтажу
- Daikin RKS60F3V1B Сервис мануал
- Daikin RKS71FAV1B Сервис мануал
- Daikin RXS60F4V1B Сервис мануал
- Daikin RXS71FAV1B9 Сервис мануал
- Hiden Expert HE33250X Технические данные
- Hiden Expert HE33250X Инструкция по эксплуатации
- Hiden Expert HE33300X Инструкция по эксплуатации
- Hiden Expert HE33300X Технические данные
- Hiden Expert HE33400X Инструкция по эксплуатации
- Hiden Expert HE33400X Технические данные
- Hiden Expert HE33500X Инструкция по эксплуатации
- Hiden Expert HE33500X Технические данные
- Hiden Expert HR3310CL Инструкция по эксплуатации
- Hiden Expert HR3310CL Технические данные
- Hiden Expert HR33015CL Инструкция по эксплуатации
- Hiden Expert HR33015CL Технические данные
- Hiden Expert HR33020CL Инструкция по эксплуатации