3 Insulate the pipes and the electric cable together at the connection of the field piping and the indoor unit piping 4 Hang the indoor unit on the hooks at the top of the mounting plate 5 Fix the bottom frame to the mounting plate see 1 3 3 Mounting the indoor unit on the mounting plate 3 5 CAUTION A When inserting the refrigerant piping in the wall hole take care not to let dust or moisture come into the piping Protect the pipes with a cap or seal the pipe end completely with tape 1 dust 2 moisture 3 tape 4 cap 4 DRAIN PIPING 4 1 CAUTIONS 2k The drain hose must slope downward to the outdoor side Do not use a trap in the drain piping Never put the end of the drain hose into water If you extend the drain hose always insulate it up to the outdoor side with polyethylene foam insulation material field supply 1 drain hose fixed to the indoor unit 2 the indoor side extension drain hose 3 wall 4 polyethylene foam 4 2 DRAIN CHECK Open the front grill see figure 5 Remove the air filters Push the knob at the centre of the air filter upwards Pull the filter downward to take it out Pour some water into the drain pan to check if the water flows smoothly 5 VACUUM DRYING OF THE INSTALLATION Refer to the installation manual of the outdoor unit 6 FIELD WIRING 6 1 CAUTIONS A All field wiring and components must be provided by a licensed electrician and must comply with the relevant local and national codes Be sure to use a dedicated power circuit Never use a power supply shared by another appliance Before supplying the power check that the voltage is within 10 of the rated voltage marked on the nameplate Take care not to bend the printed circuit board When inserting or removing the connectors 6 2 FIELD WIRING Open the front grill see figure 5 Open the service cover see figure 7 Wire in accordance with the wiring diagrams see figures 9 12 Route the field cable through the back of the indoor unit and connect to the terminal block Parts table protective earth M1S swing motor S7W operation switch C70 running capacitor MR M2R magnetic relay S2W address switch FU fuse PCB1 PCB2 printed circuit board S8W cleaning indicator reset switch H1P H2P H3P pilot lamp R1T R2T thermistor X1M terminal strip S1 S2 connector on PCB M1F fan motor Note S21 is for master control Note that the operation will restart automatically if the main power supply is turned off and then back on again 6 3 FIELD CABLE AND FIELD FUSE Use solid core cables to avoid loosening of the wires Refer to the installation manual of the outdoor unit for the required field cable section and field fuse Remove maximum 8mm of the wire insulation when connecting the wires to the terminals Insert only one wire in one terminal 6

Скачать