Tanita WB-110S MA [11/13] I o c r l f
![Tanita WB-110S MA [11/13] I o c r l f](/views2/1078141/page11/bgb.png)
A
An
RS-232C connector
(D
sub 9 pin female) is attached to the side of the display box.
When
connecting the display box with a persohal computer, e.tc., please use an RS-232C straight cable.
Use the RS232C cable ahorter than 3m long.
specifications
HNames and connection methods for signal lines
.Weighing Mode
When receiving
4
bytes of data as indicated
in
1-1 while using the scale
in
weighing mode, weight data will be output in
14
bytes, as indicated
in
1-2.
Communication standard
Communication method
Signal speed
Data bit length
Parity
Stop bit
1-1
Reception data
1234
1-2 Transmission data
EIA
RS-232C
Asynchronous method
2,400 baud
7
bit
-EVEN
1
bit
Details of Weighing Mode Transmission Data
.BM1 Mode
While the scale is used in BMI mode, the output data
will
vary
depending on the form of the received data.
a
When receiving
4
bytes of data, as indicated in
1-1,
the scale
will
calculate your BMI using the currently input height figure, and 26 bytes
of data will be output, as indicated in 2-1 or 2-2, depending on the measurement unit.
@
When receiving
11
bytes of data, including measurement units and height figures, in the form indicated in 1-2 or 1-3, the scale will
calculate your
BM1
using these figures, and 26 bytes of data will be output, as indicated
in
2-1 or 2-2, depending on the measurement
unit.
Terminal no.
1
2
3
4
5
6
-
1-1 Reception data
.
.
1-2 Reception data (height data when using kg)
Signalname
1
1234567891011
[D/HI~~
1
11
I~~o(cR/LF]
*Please input 90-99cm height data as 090-099.
TXD
RXD
GND
2-1 Transmission data (kg/ cm)
9
6
Содержание
- Instruction 1
- Qqmanvb 11 1
- Remote 1
- Safetv 3
- A stable surface with little or no vibration 4
- Accordance with the prevailing regulations 4
- Avoid subjecting the equipment to excessive shocks or vibrations when disposing of this unit please do so 4
- Clean the equipment 4
- Do not wipe the equipment with corrosive chemicals benzine cleaner etc please use a neutral detergent to 4
- Each country if an unauthorised person attempts to disassemble or repair any of the part the warranty will become invalid 4
- For electronic equipment if devices other than the original ac adapter are used or a large electrical current is applied the fuse will be blown for safety purposes if the fuse is blown the unit must be inspected and repaired as the fuse forms a fixed part of the unit and cannot be easily disassembled by the customer please consult your nearest tanita sales office or agent when the fuse needs to be 4
- Inspected in accordance with the regulations in each country 4
- Instructions for measurement 4
- Leave at least two hours before using 4
- Maintenance 4
- Measurement may not be possible on a surface that is strongly vibrating in such cases transfer the equipment to 4
- Never disassemble or adjust the equipment as this may cause malfunctions the equipment should only be 4
- Replaced 4
- The circuit board incorporates a fuse 100m4 4
- Unit to avoid causing margin errors 4
- When not in use for a long time remove the batteries before storing the equipment 4
- When not in use for a long time unplug the ac adapter from the wall socket 4
- When the equipment has been transferred to another location with a temperature difference of more than 20 c 4
- When the unit malfunctions please consult your nearest tanita sales office or agent 4
- While talung measurements please keep any persons using transmitters such as a mobile phone away from the 4
- Accessories 5
- Components 5
- Product 5
- And their meanings 6
- Bm1 mode mark 6
- Control 6
- Height 6
- Height mark 6
- Mark ready mark 6
- Stabilized mark 6
- Symbols 6
- Weight lock mark 6
- For accurate measurement place the unit on as flat a surface 7
- Installation 7
- Level adjustment 7
- Possible and adjust the level with the adjustable feet so the bubble 7
- The center of the frame 7
- The equipment 7
- The level gauge 7
- Power off interval setting 8
- Prepare power source 8
- When using dry cell batteries 8
- When using the ac adapter 8
- Be displayed as 9
- Cancellation of tare weighing function 9
- Maximum measurable weight 9
- Measurement range 9
- Negative value 9
- Net will appear next to the mark and o okg will be displayed 9
- Next to the 9
- Off the power by pressing the 9
- Repeat horn step 9
- Standard weighing procedures 9
- Tare weighing 9
- Tare weighing function 9
- Tare weight 9
- The arrow 9
- The weight 9
- The weight of the items will be displayed 9
- The weight reading will be displayed 9
- To change the tare weight cancel 9
- When the person being weighed steps off the scale the display will return to o okg 9
- Will disappear and o okg will be displayed 9
- Calculation 10
- I o c r l f 11
- Specifications 11
- Possible problems 12
- Specifications 13
Похожие устройства
- Liebherr CP 4613-21 Инструкция по эксплуатации
- Fagor IF-4S Инструкция по эксплуатации
- Tanita WB-3000 Инструкция по эксплуатации
- Tanita BD-815 Инструкция по эксплуатации
- Fagor 2V-32TS Инструкция по эксплуатации
- Bimatek JM400 Black Инструкция по эксплуатации
- Fagor 2V-33TS Инструкция по эксплуатации
- Tanita KP-601 Инструкция по эксплуатации
- Delonghi EOB2071 Инструкция по эксплуатации
- Tanita KP-400 M Инструкция по эксплуатации
- Fagor 2VFT-211AS Инструкция по эксплуатации
- Philips HP8602/00 Инструкция по эксплуатации
- Fagor IFT-4R Инструкция по эксплуатации
- Tanita Model 1579 Инструкция по эксплуатации
- Babyliss C319E Инструкция по эксплуатации
- Fagor 3FH-4GLSTXNAT Инструкция по эксплуатации
- Tanita 1479Z Инструкция по эксплуатации
- Babyliss C338E Инструкция по эксплуатации
- Fagor 6FI-4GLSX Инструкция по эксплуатации
- Tanita 1479V Инструкция по эксплуатации