- Transmit data
The measured data is output in the following format.
•Each piece data is with a comma-delimited (,).
•The terminator (the end of the data) is CR (ASCII code 0DH), LF (ASCII code 0AH). 0 herein is zero.
(1) Output data format
Transmit data is output immediately after measurement regardless of the state of the receiving side
(personal computer, etc.). Therefore, the receiving side must always be ready to receive before
measurement.
*PC mode is a mode to send personal data from the personal computer side and to receive
measurement results.
Transmission Data is output immediately after measurement regardless of the status of
the receiving equipment (personal computer, etc.). Therefore the receiving equipment
needs to be ready to accept the data before measuring.
(2) Output data items
Order of output
Item
Header
Format
Contents Body composition monitor
Scale
Adult
Athlete
Child
1111
2
Control data
Control data
{0
˜0
Fix to 16
Fix to 1
2 byte fixed length
1 byte fixed length
Control data
Control data
˜1
˜2
Fix to 1
Fix to 1
1 byte fixed length
1 byte fixed length
Model
Serial No.
MO
SN
”XXXXXX”
”XXXXXXXX”
8 byte fixed length
10 byte fixed length
ID number
Date (dd/mm/yyyy)
ID
Da
”XXXXXXXXXX”
”dd/mm/yyyy”
12 byte fixed length
12 byte fixed length
Time
Body type
TI
Bt
”hh:mm”
0 or 2
7 byte fixed length
1 byte fixed length (0: standard 2: athlete)
Gender
Age
GE
AG
1 or 2
XX
1 byte fixed length (1: male 2: female)
“1 – 2 byte variable length (unit: age, right-aligned)”
Height
Clothes (tare)
Hm
Pt
XXX.X
XX.X
“4 – 5 byte variable length, to 1 place of decimals (unit: cm)”
“3 – 4 byte variable length, to 1 place of decimals (unit: kg)”
Weight
Body fat %
Wk
FW
XXX.X
XX.X
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
“3 – 4 byte variable length, to 1 place of decimals (unit: %)”
Fat mass
Fat free mass
fW
MW
XXX.X
XXX.X
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
Muscle mass
Muscle score
mW
sW
XXX.X
XX
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
1 – 2 byte variable length (1-24)
Bone mass
TBW
bW
wW
XXX.X
XXX.X
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
TBW %
BMI
ww
MI
XXX.X
XXX.X
“3 – 5 byte variable length, to 1 place of decimals”
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
Standard body weight
Degree of obesity
Sw
OV
XXX.X
XX.XX
“3 – 5 byte variable length, to 1 place of decimals (unit: kg)”
“3 – 5 byte variable length, to 1 place of decimals (unit: %)”
Visceral fat rating
BMR (kJ)
IF
rb
XX
XXXXX
1 – 2 byte variable length
1 – 5 byte variable length (unit: kJ)
BMR (kcal)
BMR score
rB
rJ
XXXXX
XX
1 – 5 byte variable length (unit: kcal)
1 – 2 byte variable length
Metabolic age
Rohrer’s index
rA
RO
XX
XXXX.X
2 byte fixed length
4 – 6 byte variable length
Target body fat %
Predicted weight
Fat to gain / lese
Checksum
gF
gW
gt
CS
XX
XXX.X
XXXX.X
XX
1 – 2 byte variable length
3 – 5 byte variable length
3 – 6 byte variable length
2 byte fixed length
Predicted fat mass
Impedance
gf
ZF
XXX.X
XXXX.X
3 – 5 byte variable length
5 – 6 byte variable length
2 2 2
333
4 4 4
5553
6 6 6 4
7775
8 8 8 6
9997
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14 8
15 15 15 9
16 16 16
17 17 17
18 18 18
19 19 19
20 20
21 21
22 22 20
23 23 21
24 24
25
26
27 25
28 26
29 27
30 28
31 29
22
32 30 23
33
35
37
31
33
35
24
26
28 10
34
36
32
34
25
27
Содержание
- Body composition analyzer sc 330 1
- Instruction manual 1
- Applications 2
- Before use 2
- Benefits 2
- How to use 2
- Operating instruction 2
- Table of contents 2
- When necessary 2
- Before use 4
- Product assembly and components 4
- Remote display version column mounted version 4
- Preparation 5
- Setting of the printer paper roll 5
- Setting methods 6
- Various settings 6
- Setting methods continued 7
- Various settings 7
- Setting methods continued 8
- Various settings 8
- Setting methods continued 9
- Various settings 9
- Setting methods continued 10
- Various settings 10
- Before use 11
- Setting methods continued 11
- Various settings 11
- Setting methods continued 12
- Various settings 12
- About athletic mode 13
- In the case of the standard flow not the one step mode 13
- Operating instructions 13
- Operating instructions 14
- When using as a body composition analyzer continued 14
- Operating instructions 15
- In the case of the one step mode 16
- Operating instructions 16
- Operating instructions 17
- Operating instructions 18
- Target body fat ratio 18
- When using as a scale 18
- How to use 19
- Operating instructions 19
- Criteria based on body fat percentage 20
- How to use 20
- Various criteria 20
- What is total body water percentage 20
- What is visceral fat rating 20
- How to use 21
- What is basal metabolic rate bmr 21
- What is mascle mass 21
- What is metabolic age 21
- What is physique rating 21
- Display part 22
- How to measure 22
- Printer 22
- Troubleshooting 22
- When necessary 22
- Connection example 23
- Connection with a personal computer 23
- Signal names and connection methods 23
- Specifications 23
- When necessary 23
- 1 output data format 24
- 2 output data items 24
- Transmit data 24
- When necessary 24
- Body composition measurement by the bia method 25
- Technical notes 25
- When necessary 25
- Factors giving errors in measurement 26
- Inter day changes 26
- When necessary 26
- Comparison of bmr values from the tanita multiple regression model and breath analysis 27
- The new regression formula for basal metabolic rate bmr 27
- The relationship between resting energy expenditure ree according to breath gas analysis and weight ffm 27
- When necessary 27
- Specifications 28
- When necessary 28
Похожие устройства
- Bosch DWB09D651 Инструкция по эксплуатации
- Fagor FET-3106 Инструкция по эксплуатации
- Tanita SC 330P Инструкция по эксплуатации
- Bosch DWA09D651 Инструкция по эксплуатации
- Rikon RKN 11 Инструкция по эксплуатации
- Tanita SC 240 MA Инструкция по эксплуатации
- Gorenje DK2000 P2 B Инструкция по эксплуатации
- Fagor 5CF-4VMCX Инструкция по эксплуатации
- Tanita MC 980 MA Инструкция по эксплуатации
- Siemens LC958BA90 Инструкция по эксплуатации
- Fagor 5CF-56MSPB Инструкция по эксплуатации
- Tanita BF 522 W Инструкция по эксплуатации
- Gorenje DK9P2X Инструкция по эксплуатации
- Tanita BF 350 Инструкция по эксплуатации
- Fagor 5CF-56VDPX Инструкция по эксплуатации
- Siemens LI28031 Инструкция по эксплуатации
- Tanita BC 420 MA Инструкция по эксплуатации
- Fagor 5CH-56GSF B Инструкция по эксплуатации
- Siemens LI 46631 Инструкция по эксплуатации
- Fagor 6CF-56EB Инструкция по эксплуатации