Daikin FTXD60JV1B [21/164] Name of connectors for outdoor unit

Daikin FTXD50JV1B [21/164] Name of connectors for outdoor unit
SiBE04-101 Printed Circuit Board Connector Wiring Diagram and Name
Printed Circuit Board Connector Wiring Diagram 13
1.4 Name of Connectors for Outdoor Unit
Note: Other Designation
1) S3, S5, S7, S8 Connector for PCB 2
2) S20, S80 Connector for 4 Way Valve Coil (Heat Pump Only)
3) S40 Connector for TFU (76˚C)
4) S50 Connector for Long Piping Jumper
5) S70 Connector for Fan Motor
6) S90 Connector for Thermistor
7) S101 Connector for Active Module
8) S110 Harness for PCB 1
9) S200, S210, S220 Connector for PCB 1
10) S230 Connector for Compressor Motor (UVWN)
1) V1, V3 Varistor
2) LED A, LED 1 to 4 Service Monitor LED
SiBE04-101.book Page 13 Monday, October 15, 2001 3:08 PM