Daikin FHYP100BV1 [11/28] View from the front
![Daikin FHYP45BV1 [11/28] View from the front](/views2/1782952/page11/bgb.png)
3
Dimensional drawings
FHYP35∼45BV1
View from the front
780 From the floor side 2500 or more
(Required space)
Note:
1. Location of unit’s name plate: bottom of fan housing inside the suction
grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the machine)
attached.
(0.5 mm
2
x 2 Wicks x O.D. J5.4)
(It is not attached in VRV.)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection J12.7 flare
5 Liquid pipe connection J6.4 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole- slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26
Position: hole of wall for taking out in piping back
For height installation
Floor side
300or more
Brand name plate
(For left piping)
30 or more
30 or more
(Service space)
(View from the front)
(Hanging position)
Hanging bolt
Position slit hole for taking out in piping back
3D027536C
Drain pipe connection
VP20
Obstacle
(Service space)
(View from the front)
(Hanging position)
(Required space)
(Required space)
(Note 2)
FHYP60∼71BV1
View from the front
780 From the floor side 2500 or more
(Required space)
Note:
1. Location of unit’s name plate: bottom of fan housing inside the suction
grille.
2. In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control in detail.
3. The remote control code is the standard (about 3m outside the machine)
attached.
(0.5 mm
2
x 2 Wicks x O.D. J5.4)
(It is not attached in VRV.)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection J15.9 flare
5 Liquid pipe connection J9.5 flare
6 Drain pipe connection VP20
7 Earth terminal (inside the electric components box) M4
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection - slit hole
12 Left back drain pipe connection - slit hole
13 Right side drain pipe connection - slit hole
14 Right side drain piping connection hole- slit hole
15 Hole of wall for taking out in piping back J100
16 Upward drain pipe connection J60
17 Upward gas pipe connection J36
18 Upward liquid pipe connection J26
Position: hole of wall for taking out in piping back
For height installation
Floor side
300 or more
Brand name plate
(For left piping)
30 or more
30 or more
(Service space)
(View from the front)
(Hanging position)
Hanging bolt
Position slit hole for taking out in piping back
3D027538B
Drain pipe connection
VP20
Obstacle
(Service space)
(View from the front)
(Hanging position)
(Required space)
(Required space)
(Note 2)
•
Ceiling Suspended Unit • R-407C • FHYP35-125BV1
1
3
9
• Split - Sky Air • Indoor Units
Содержание
- Air conditioning systems 1
- Split sky air 1
- Technical data 1
- B 8400 ostend belgium 2
- Eede03 1 2 03 2003 prepared in belgium by goekint graphics 2
- Internet http www daikineurope com 2
- Specifications are subject to change without prior notice 2
- Split sky air 2
- Zandvoordestraat 300 2
- Table of contents 3
- Table of contents fhyp b 3
- Features 4
- Specifications 5
- Specifications 6
- Specifications 7
- Specifications 8
- Specifications 9
- Specifications 10
- Dimensional drawings 11
- View from the front 11
- Dimensional drawings 12
- View from the front 12
- Piping diagrams 13
- Switch box 14
- Wiring diagrams 14
- Sound level 15
- Sound level data 15
- Sound pressure spectrum 15
- Sound level 16
- Air flow patterns 17
- Air flow patterns 18
- Air flow patterns 19
- Air flow patterns 20
- Air flow patterns 21
- Air flow patterns 22
- Air flow patterns 23
- Air flow patterns 24
- Accessories 25
- Optional accessories 25
- Standard accessories 25
- Accessories 26
- Control systems 27
- Cover closed 27
- Cover open 27
- Wired remote control 27
- Installation 28
- Safety device settings 28
Похожие устройства
- Daikin FHYP100BV1 Сервис мануал
- Daikin FHYP125BV1 Инструкция по эксплуатации
- Daikin FHYP125BV1 Инструкция по монтажу
- Daikin FHYP125BV1 Технические данные
- Daikin FHYP125BV1 Сервис мануал
- FROSP XMD-111 Инструкция по эксплуатации
- FROSP XMD-121 Инструкция по эксплуатации
- FROSP XMD-151 Инструкция по эксплуатации
- FROSP K-313PD Инструкция по эксплуатации
- FROSP К-12003 Инструкция по эксплуатации
- FROSP К-12004 Инструкция по эксплуатации
- FROSP ПН-1 Инструкция по эксплуатации
- FROSP GS-10 Инструкция по эксплуатации
- FROSP RK-178-V6L Инструкция по эксплуатации
- FROSP RK-128-V5 Инструкция по эксплуатации
- FROSP RK-128-V6 Инструкция по эксплуатации
- FROSP RK-168-V5L Инструкция по эксплуатации
- FROSP RK-158-V5L Инструкция по эксплуатации
- FROSP К-4006 А Инструкция по эксплуатации
- FROSP SC 5C-8 Инструкция по эксплуатации