Daikin FTXJ35LV1BW [10/16] Boring a wall hole and installing wall embedded pipe
![Daikin FTXJ25LV1BW [10/16] Boring a wall hole and installing wall embedded pipe](/views2/1784669/page10/bga.png)
8 ■English
Indoor Unit Installation
1. Installing the mounting plate
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the unit is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
2. Boring a wall hole and installing wall embedded pipe
• For walls containing metal frame or metal board, be sure to use a
wall embedded pipe and wall hole cover in the feed-through hole to
prevent possible heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down
slope toward the outside.
2) Insert a wall embedded pipe into the hole.
3) Insert a wall hole cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk
pipe hole gap with putty.
3. Inter-unit wiring
1) Remove the upper front panel, then remove the service
lid.
2) Pass the inter-unit wire from the outdoor unit through the
feed-through wall hole and then through the back of the
indoor unit. Pull them through the front side. Bend the
ends of tie wires upward for easier work in advance. (If
the inter-unit wire ends are to be stripped first, bundle
wire ends with adhesive tape.)
3) Press the bottom frame of the indoor unit with both
hands to set it on the mounting plate hooks. Make sure
the wires do not catch on the edge of the indoor unit.
(Bolt size: M10)
Use tape measure
as shown.
Position the end of
tape measure at .
(Bolt size: M10)
Gas pipe endLiquid pipe end
Place a leveler
on raised tab.
Through-the-wall hole φ65
unit: mm
Drain hose
position
Keep here the piece
cut out from the unit
for piping
998
357
135142
348
160 151
φ65
φ65
49 100
200124
303
49
50
203 234
67
Recommended mounting plate
retention spots (5 spots in all)
Inside Outside
Caulking
(field supply)
Wall embedded pipe
(field supply)
Wall hole cover
(field supply)
Wall embedded pipe
(field supply)
φ65
Hang indoor unit’s hook here.
When stripping off the ends of inter-unit
wire in advance, cover the ends with
insulating tape to make it easier to pass
the wire.
A Mounting plate
Inter-unit
wire
Содержание
- Daikin room air conditioner 1
- Installation manual 1
- Models 1
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Ftxj20lv1bw ftxj25lv1bw ftxj35lv1bw ftxj50lv1bw ftxj20lv1bs ftxj25lv1bs ftxj35lv1bs ftxj50lv1bs ftxm20k3v1b ftxm25k3v1b ftxm35k3v1b ftxm42k3v1b ftxm50k3v1b 2
- Low voltage 2006 95 ec machinery 2006 42 ec electromagnetic compatibility 2004 108 ec 2
- P390250 3 2
- Takayuki fujii managing director pilsen 3rd of nov 2014 2
- English 1 3
- Read the precautions in this manual carefully before operating the unit this appliance is filled with r32 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- Indoor unit 4
- Wireless remote controller 4
- Caution 5
- English 3 5
- Indoor unit installation drawings 5
- Intelligent eye sensor 5
- Installation tips 6
- Removing and installing the front grille 6
- Removing and installing the upper front panel 6
- Caution 7
- How to set the different addresses 7
- Installation tips 7
- When connecting to an ha system wired remote controller central remote controller etc 7
- Flaring the pipe end 8
- Installation tips 8
- Refrigerant piping work 8
- Warning 8
- Caution 9
- Refrigerant piping 9
- Refrigerant piping work 9
- Boring a wall hole and installing wall embedded pipe 10
- Indoor unit installation 10
- Installing the mounting plate 10
- Inter unit wiring 10
- Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape 2 wrap the inter unit wire refrigerant pipes and drain hose together with insulation tape 11
- Attachment on the right side factory default attachment on the left side 11
- Drain hose attachment position 11
- Front side of unit 11
- How to replace the drain plug and drain hose 11
- How to set drain plug 11
- Indoor unit installation 11
- Laying piping hoses and wiring 11
- Pass the inter unit wire drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide 11
- Replace the drain plug and drain hose 2 attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape 3 be sure to connect the drain hose to the drain port in place of a drain plug 11
- Shape the refrigerant pipe along the pipe path marking on the mounting plate 5 pass drain hose and refrigerant pipes through the wall hole then set the indoor unit on mounting plate hooks using the markings at the top of indoor unit as a guide 6 pull in the inter unit wire 7 connect the inter unit pipes 8 wrap the refrigerant pipes and drain hose together with insulation tape as shown in the figure on the right in case of setting the drain hose through the back of the indoor unit 11
- The recommended installation method is back piping when performing bottom piping or side piping refer to 5 bottom or side piping on page 10 11
- Bottom or side piping 12
- Indoor unit installation 12
- Left side piping 12
- Right bottom piping left bottom piping 12
- Right side piping 12
- Caution 13
- Do not use tapped wires extension cords or starburst connections as they may cause overheating electrical shock or fire do not use locally purchased electrical parts inside the product do not branch the power for the drain pump etc from the terminal block doing so may cause electric shock or fire do not connect the indoor unit to the mains electricity connect it to the outdoor unit only or there may be danger of electric shock or fire 13
- Firmly fix the wires with the terminal screws 13
- Firmly fix the wires with the terminal screws outdoor unit 13
- Firmly secure wire retainer so that wires sustain no external stress 13
- Indoor unit 13
- Indoor unit installation 13
- Inter unit wire 4 core 1 m 13
- Or more h05rn 13
- Shape wires so that the service lid will fit securely 13
- Strip wire ends 15mm 2 match wire colours with terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the corresponding terminals 3 connect the earth wires to the corresponding terminals 4 pull wires to make sure that they are securely latched up then retain wires with wire retainer 5 in case of connecting to an adapter system run the remote controller cable and attach the s21 6 shape the wires so that the service lid fits securely then close service lid 13
- Terminal block electrical component box 13
- Warning 13
- When connecting the connection wires to the terminal block using a single core wire be sure to perform curling problems with the installation may cause heat and fires 13
- Wire retainer use the specified wire type 13
- Wiring 13
- Drain piping 14
- Indoor unit installation 14
- Test items 15
- Trial operation and testing 15
- Trial operation from remote controller 15
Похожие устройства
- Daikin FTXJ35LV1BW Инструкция по эксплуатации
- Daikin FTXJ50LV1BW Инструкция по монтажу
- Daikin FTXJ50LV1BW Инструкция по эксплуатации
- Daikin FTXJ20LV1BS Инструкция по монтажу
- Daikin FTXJ20LV1BS Инструкция по эксплуатации
- Daikin FTXJ25LV1BS Инструкция по монтажу
- Daikin FTXJ25LV1BS Инструкция по эксплуатации
- Daikin FTXJ35LV1BS Инструкция по монтажу
- Daikin FTXJ35LV1BS Инструкция по эксплуатации
- Daikin FTXJ50LV1BS Инструкция по монтажу
- Daikin FTXJ50LV1BS Инструкция по эксплуатации
- Daikin FTD50FV1K Инструкция по эксплуатации
- Daikin FTD60FV1K Инструкция по эксплуатации
- Daikin FTD20JEV1K Инструкция по монтажу
- Daikin FTD20JEV1K Инструкция по эксплуатации
- Daikin FTD25JEV1K Инструкция по монтажу
- Daikin FTD25JEV1K Инструкция по эксплуатации
- Daikin RD20JEV1K Инструкция по эксплуатации
- Daikin RD20JEV1K Инструкция по монтажу
- Daikin RD25JEV1K Инструкция по эксплуатации