Daikin FTD50FV1K [12/24] To change the air flow rate setting
![Daikin FTD50FV1K [12/24] To change the air flow rate setting](/views2/1784685/page12/bgc.png)
11
■ To change the air flow rate setting
5. Press “FAN setting button”.
NOTE
DRY mode COOL or FAN mode
The air flow rate setting is not variable.
Five levels of air flow rate setting from “ ” to “ ”
plus “ ” are available.
■
Note on COOL operation
• This air conditioner cools the room by blowing the hot air in the room outside, so if the
outside temperature is high, performance drops.
■
Note on DRY operation
• The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and fan strength, so manual
adjustment of these functions is unavailable.
■
Note on air flow rate setting
•
At smaller air flow rates, the cooling effect is also smaller.
01_EN_3P175973-5A.fm Page 11 Thursday, November 2, 2006 3:18 PM
Содержание
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Caution 3
- Safety precautions 3
- Warning 3
- Consider nuisance to your neighbours from noises 4
- Electrical work 4
- Installation site 4
- System relocation 4
- Indoor unit 5
- Names of parts 5
- Class 60 class 6
- Outdoor unit 6
- Remote controller 7
- Attention 8
- Preparation before operation 8
- To set the batteries 8
- Attention 9
- Choose a place from where the sig nals reach the unit 9
- Fix the holder to a wall a pillar etc with the screws supplied with the holder 9
- Place the remote controller in the remote controller holder 9
- Preparation before operation 9
- To fix the remote controller holder on the wall 9
- To operate the remote controller 9
- Press clock button 10
- Press timer setting button to set the clock to the present time 10
- To set the clock 10
- Turn the breaker on 10
- Dry cool fan operation 11
- Press mode selector button and select a operation mode 11
- Press on off button 11
- Press on off button again 11
- Press temperature adjustment button 11
- To change the temperature setting 11
- To start operation 11
- To stop operation 11
- Press fan setting button 12
- To change the air flow rate setting 12
- Adjusting the air flow direction 13
- Notes on flaps and louvers angles 13
- To adjust the horizontal blades flaps 13
- To adjust the vertical blades louvers 13
- Powerful operation 14
- To cancel powerful operation 14
- To start powerful operation 14
- Timer operation 15
- To cancel the off timer operation 15
- To use off timer operation 15
- Attention 16
- Press cancel button 16
- Press on timer button 16
- Press on timer button again 16
- Press timer setting button until the time setting reaches the point you like 16
- To cancel on timer operation 16
- To combine on timer and off timer 16
- To use on timer operation 16
- Attach the front panel 17
- Before cleaning be sure to stop the operation and turn the breaker off 17
- Care and cleaning 17
- Caution 17
- Clean the front panel 17
- Front panel 17
- Indoor unit outdoor unit and remote controller 17
- Open the front panel 17
- Remove the front panel 17
- Wipe them with dry soft cloth 17
- Air filter 18
- Filters 18
- Maintenance 18
- Replacement 18
- Titanium apatite photocatalytic air purifying filter 18
- After operation stops turn off the breaker for the room air conditioner 19
- Before a long idle period 19
- Clean the air filters and set them again 19
- Operate the fan only for several hours on a fine day to dry out the inside 19
- Press mode selector button and select fan operation 19
- Press on off button and start operation 19
- Take out batteries from the remote controller 19
- Titanium apatite photocatalytic air purifying filter without frame 1 set 19
- To order titanium apatite photocatalytic air purifying filter contact to the service shop there you bought the air conditioner dispose of old filters as non flammable waste 19
- Case explanation 20
- These cases are not troubles 20
- Trouble shooting 20
- Case check 21
- Check again 21
- Call the service shop immediately 22
- The power cord is abnormally hot or damaged an abnormal sound is heard during operation the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently a switch or a button often fails to work properly there is a burning smell water leaks from the indoor unit 22
- Turn the breaker off and call the service shop 22
- Warning 22
- We recommend periodical maintenance 22
Похожие устройства
- Daikin FTD60FV1K Инструкция по эксплуатации
- Daikin FTD20JEV1K Инструкция по монтажу
- Daikin FTD20JEV1K Инструкция по эксплуатации
- Daikin FTD25JEV1K Инструкция по монтажу
- Daikin FTD25JEV1K Инструкция по эксплуатации
- Daikin RD20JEV1K Инструкция по эксплуатации
- Daikin RD20JEV1K Инструкция по монтажу
- Daikin RD25JEV1K Инструкция по эксплуатации
- Daikin RD25JEV1K Инструкция по монтажу
- Daikin RD30JEV1K Инструкция по эксплуатации
- Daikin RD30JEV1K Инструкция по монтажу
- Daikin RD40JEV1K Инструкция по эксплуатации
- Daikin RD40JEV1K Инструкция по монтажу
- Daikin RD40JEY1K Инструкция по эксплуатации
- Daikin RD40JEY1K Инструкция по монтажу
- Daikin RD50JEY1K Инструкция по эксплуатации
- Daikin RD50JEY1K Инструкция по монтажу
- Daikin RD60JEY1K Инструкция по эксплуатации
- Daikin RD60JEY1K Инструкция по монтажу
- Daikin FHC20JEV1K Инструкция по эксплуатации