Daikin FTXTA30B2V1BB [3/12] To remove the accessories from the indoor unit
![Daikin FTXTA30B2V1BB [3/12] To remove the accessories from the indoor unit](/views2/1785510/page3/bg3.png)
3 About the box
Installation manual
3
FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P482320-12U – 2021.03
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
CAUTION
For walls containing a metal frame or a metal board, use a
wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
Piping installation (see "6Piping installation"[46])
CAUTION
Piping and joints of a split system shall be made with
permanent joints when inside an occupied space except
joints directly connecting the piping to the indoor units.
DANGER: RISK OF BURNING/SCALDING
CAUTION
▪ Use the flare nut fixed to the unit.
▪ To prevent gas leakage, apply refrigeration oil only to
the inside of the flare. Use refrigeration oil for R32.
▪ Do NOT reuse joints.
CAUTION
▪ Do NOT use mineral oil on flared part.
▪ NEVER install a drier to this R32 unit to guarantee its
lifetime. The drying material may dissolve and damage
the system.
CAUTION
▪ Incomplete flaring may cause refrigerant gas leakage.
▪ Do NOT re-use flares. Use new flares to prevent
refrigerant gas leakage.
▪ Use flare nuts that are included with the unit. Using
different flare nuts may cause refrigerant gas leakage.
Electrical installation (see "7Electrical installation"[47])
DANGER: RISK OF ELECTROCUTION
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
legislation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction MUST comply with the applicable
legislation.
WARNING
▪ If the power supply has a missing or wrong N-phase,
equipment might break down.
▪ Establish proper earthing. Do NOT earth the unit to a
utility pipe, surge absorber, or telephone earth.
Incomplete earthing may cause electrical shock.
▪ Install the required fuses or circuit breakers.
▪ Secure the electrical wiring with cable ties so that the
cables do NOT come in contact with sharp edges or
piping, particularly on the high-pressure side.
▪ Do NOT use taped wires, stranded conductor wires,
extension cords, or connections from a star system.
They can cause overheating, electrical shock or fire.
▪ Do NOT install a phase advancing capacitor, because
this unit is equipped with an inverter. A phase
advancing capacitor will reduce performance and may
cause accidents.
WARNING
Use an all-pole disconnection type breaker with at least
3 mm between the contact point gaps that provide full
disconnection under overvoltage category III.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
WARNING
Do NOT connect the power supply to the indoor unit. This
could result in electrical shock or fire.
WARNING
▪ Do NOT use locally purchased electrical parts inside
the product.
▪ Do NOT branch the power supply for the drain pump,
etc. from the terminal block. This could result in
electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes
without thermal insulation as such pipes will be very hot.
3 About the box
3.1 Indoor unit
3.1.1 To remove the accessories from the
indoor unit
1 Remove:
▪ the accessory bag located at the bottom of the package,
▪ the mounting plate attached to the back of the indoor unit,
▪ the spare SSID sticker located on the front grille.
1×2× 2× 2×1× 1× 1×1× 1× 1×
edba c f g
2×
j kh i
a Installation manual
b Operation manual
c General safety precautions
Содержание
- Daikin room air conditioner 1
- Ftxta30b2v1bw ftxta30b2v1bb 1
- Installation manual 1
- A subset of the latest technical data is available on the regional 2
- About the box 3 2
- About the documentation 2
- About the documentation 2 2
- About the unit 4 2
- About this document 2
- Always observe the following safety instructions and regulations 2
- And manuals product information 2
- Authorised installers 2
- Business portal authentication required 2
- Commissioning 10 2
- Configuration 9 2
- Daikin website publicly accessible 2
- Disposal 10 2
- Documentation set 2
- Electrical installation 7 2
- Finishing the indoor unit installation 8 2
- Format digital files on http www daikineurope com support 2
- Format paper in the box of the indoor unit 2
- General safety precautions 2
- Indoor unit installation manual 2
- Information 2
- Installation instructions 2
- Installation manual 2
- Installation shall be done by an installer the choice of materials and installation shall comply with the applicable legislation in europe en378 is the applicable standard 2
- Installer reference guide 2
- Latest revisions of the supplied documentation may be available on the regional daikin website or via your dealer 2
- Make sure installation servicing maintenance repair and applied materials follow the instructions from daikin and in addition comply with applicable legislation and are performed by qualified persons only in europe and areas where iec standards apply en iec 60335 2 40 is the applicable standard 2
- Make sure that the user has the printed documentation and ask him her to keep it for future reference 2
- Piping installation 6 2
- Preparation of the installation good practices reference data 2
- Safety instructions that you must read before installing 2
- Specific installer safety instructions 2
- Specific installer safety instructions 2 2
- Table of contents 2
- Target audience 2
- Technical data 10 2
- Technical engineering data 2
- The full set of latest technical data is available on the daikin 2
- The original documentation is written in english all other languages are translations 2
- This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons 2
- This document is part of a documentation set the complete set consists of 2
- Unit installation 4 2
- Unit installation see 5 unit installation 4 4 2
- Warning 2
- About the box 3
- Indoor unit 3
- To remove the accessories from the indoor unit 3
- About the unit 4
- About the wireless lan 4
- Basic parameters 4
- Installation site requirements of the indoor unit 4
- Operation range 4
- Precautions when using the wireless lan 4
- Preparing the installation site 4
- Unit installation 4
- Mounting the indoor unit 5
- To drill a wall hole 5
- To install the mounting plate 5
- Unit installation 5
- Connecting the drain piping 6
- Piping installation 6
- Preparing refrigerant piping 6
- Refrigerant piping requirements 6
- To check for water leaks 6
- To connect the piping on left side left back or left bottom 6
- To connect the piping on right side right back or right bottom 6
- To remove the pipe port cover 6
- Connecting the refrigerant piping 7
- Electrical installation 7
- Refrigerant piping diameter 7
- Refrigerant piping insulation 7
- Refrigerant piping material 7
- Specifications of standard wiring components 7
- To connect the refrigerant piping to the indoor unit 7
- Finishing the indoor unit installation 8
- To connect optional accessories wired user interface central user interface etc 8
- To connect the electrical wiring to the indoor unit 8
- To insulate the drain piping refrigerant piping and interconnection cable 8
- Configuration 9
- To fix the unit on the mounting plate 9
- To pass the pipes through the wall hole 9
- To set a different address 9
- Checklist before commissioning 10
- Commissioning 10
- Disposal 10
- Technical data 10
- To perform a test run 10
- To perform a test run using the user interface 10
- Unified wiring diagram legend 10
- Wiring diagram 10
- Technical data 11
Похожие устройства
- Daikin FTXTA30B2V1BB Инструкция по эксплуатации
- Daikin FTXTA30B2V1BB Справочник пользователя
- Daikin FTXTA30B2V1BW Инструкция по монтажу
- Daikin FTXTA30B2V1BW Инструкция по эксплуатации
- Daikin FTXTA30B2V1BW Справочник пользователя
- Daikin ARXM25M3V1B9 Инструкция по монтажу
- Daikin ARXM35M3V1B9 Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по монтажу
- Daikin ATXC20CV1B Инструкция по эксплуатации
- Daikin ATXC25CV1B Инструкция по монтажу
- Daikin ATXC25CV1B Инструкция по эксплуатации
- Daikin ATXC35CV1B Инструкция по монтажу
- Daikin ATXC35CV1B Инструкция по эксплуатации
- ПКБ АРМА ДША-А14,4В3,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-А18В1,5-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В2,0-2-2 Инструкция по эксплуатации
- ПКБ АРМА ДШУА-С18В3,0-1-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A1150-2 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-А900-1 Инструкция по эксплуатации
- ПКБ АРМА ДэУ-A720-2 Инструкция по эксплуатации