______________________________________ ADDITIONAL CHARGE_________________________________________ The refrigerant is pre charged in the outdoor unit If the piping length is less than 7 5m then additional charge after vacuuming is not necessary If the piping length is more than 7 5m then use the additional charge value as indicated in the table Additional refrigerant charge g per additional Im length as tabulated Indoor FTYN 20 25 35 50 60 Outdoor RYN 20 25 35 50 60 Additional charge g m 16 16 16 16 16 Example FTYN25 RYN25 with 12m piping length additional piping length is 4 5m Thus Additional charge 4 5 m x 16 g m 72 0 g INDICATOR LIGHTS IR Signal Receiver When an transmitted infrared the remote signal control receiver on operating the signal indoor unit has will been respond as below to confirm acceptance of the signal transmission ON to OFF 1 Long Beep OFF to ON Pump down Cool force on 2 Short Beq Others 1 Short Beep Heat Pump Unit LED Indicator Lights for Heat Pump Unit The table shows the LED indicator lights for the air conditioner unit under normal operation and fault conditions The LED indicator lights are located at the right bottom of IR Receiver the air conditioner unit The sensor heat pump whereby units it will are equipped provide with reasonable by switching automatically to cither according to the temperature set by the user cool an room or auto mode Cool Heat temperature heat Timer Sleep mode ON OFF switch 1 12