Daikin EHVH16SU26CB6W [3/28] For the user
![Daikin EHVH16SU26CB6W [3/28] For the user](/views2/1786232/page3/bg3.png)
2 About this document
User reference guide
3
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
WARNING
Indicates a situation that could result in death or serious
injury.
WARNING: FLAMMABLE MATERIAL
CAUTION
Indicates a situation that could result in minor or moderate
injury.
NOTICE
Indicates a situation that could result in equipment or
property damage.
INFORMATION
Indicates useful tips or additional information.
Symbol Explanation
Before installation, read the installation and
operation manual, and the wiring instruction sheet.
Before performing maintenance and service tasks,
read the service manual.
For more information, see the installer and user
reference guide.
1.2 For the user
▪ If you are not sure how to operate the unit, contact your installer.
▪ This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall
not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
WARNING
To prevent electric shocks or fire:
▪ Do NOT rinse the unit.
▪ Do NOT operate the unit with wet hands.
▪ Do NOT place any objects containing water on the unit.
NOTICE
▪ Do NOT place any objects or equipment on top of the
unit.
▪ Do NOT sit, climb or stand on the unit.
▪ Units are marked with the following symbol:
This means that electrical and electronic products may not be
mixed with unsorted household waste. Do NOT try to dismantle
the system yourself: the dismantling of the system, treatment of
the refrigerant, of oil and of other parts must be done by an
authorized installer and must comply with applicable legislation.
Units must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed of
correctly, you will help to prevent potential negative consequences
for the environment and human health. For more information,
contact your installer or local authority.
▪ Batteries are marked with the following symbol:
This means that the batteries may not be mixed with unsorted
household waste. If a chemical symbol is printed beneath the
symbol, this chemical symbol means that the battery contains a
heavy metal above a certain concentration.
Possible chemical symbols are: Pb: lead (>0.004%).
Waste batteries must be treated at a specialized treatment facility
for reuse. By ensuring waste batteries are disposed of correctly,
you will help to prevent potential negative consequences for the
environment and human health.
2 About this document
Thank you for purchasing this product. Please:
▪ Read the documentation carefully before operating the user
interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used
to configure your system. Check if he has filled in the installer
settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Target audience
Endusers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before operating your
system
▪ Format: Paper (in the box of the indoor unit)
▪ Operation manual:
▪ Quick guide for basic usage
▪ Format: Paper (in the box of the indoor unit)
▪ User reference guide:
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.
The original documentation is written in English. All other languages
are translations.
Available screens
Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.
Breadcrumbs
1
20.0°C >
18.0°C >
7.4.1.1 Room temperature
Comfort (heating)
Eco (heating)
Select
Scroll
Breadcrumbs help you to locate where you are in the menu structure
of the user interface. This document also mentions these
breadcrumbs.
Содержание
- Daikin altherma low temperature split 1
- User reference guide 1
- About the documentation 2
- About the system 4 2
- About this document 3 2
- Danger 2
- Danger risk of burning 2
- Danger risk of electrocution 2
- Danger risk of explosion 2
- Disposal 24 2
- Energy saving tips 22 2
- General safety precautions 2
- General safety precautions 2 2
- Glossary 24 2
- Indicates a situation that could result in burning because of extreme hot or cold temperatures 2
- Indicates a situation that could result in electrocution 2
- Indicates a situation that could result in explosion 2
- Indicates a situation that results in death or serious injury 2
- Installation manual and the installer reference guide must be performed by an authorized installer 2
- Languages are translations 2
- Maintenance and service 23 2
- Meaning of warnings and symbols 2
- Operation 4 2
- Relocation 24 2
- Setting the energy prices 21 2
- Table of contents 2
- The installation of the system and all activities described in the 2
- The original documentation is written in english all other 2
- The precautions described in this document cover very important 2
- Topics follow them carefully 2
- Troubleshooting 23 2
- User reference guide 2
- About this document 3
- For the user 3
- About the system 4
- Buttons 4
- Components in a typical system layout 4
- G b c a 4
- Operation 4
- Overview operation 4
- The user interface at a glance 4
- Basic usage 5
- Operation 5
- Status icons 5
- Turning on off controls 5
- Using home pages 5
- Using the menu structure 5
- About space heating control 6
- Determining which temperature control you are using 6
- Operation 6
- Room thermostat control about room thermostat control 6
- Setting the space operation mode 6
- Space heating control 6
- To determine which temperature control you are using method 1 6
- To determine which temperature control you are using method 2 6
- Example temporarily overruling the schedule and changing the mode to preset value 7
- Operation 7
- Room thermostat control using the room temperature home page 7
- To change the mode from scheduled to preset value 7
- To read out the actual and desired room temperature 7
- To temporarily overrule the room temperature schedule 7
- Typical room temperature home pages 7
- Operation 8
- To set the overrule period 8
- C 37 c 9
- C 47 c 9
- Operation 9
- About domestic hot water control 10
- C 37 c 10
- C 47 c 10
- Domestic hot water control 10
- External room thermostat control about external room thermostat control 10
- External room thermostat control using external room thermostat control 10
- Leaving water temperature control using leaving water temperature control according to a schedule 10
- Leaving water temperature control using leaving water temperature control not according to a schedule 10
- Operation 10
- To adjust the leaving water temperature additional 10
- To adjust the leaving water temperature main 10
- To set leaving water temperature preset values main 10
- 00 07 00 11
- 00 21 00 11
- Operation 11
- Reheat mode 11
- Scheduled mode 11
- Operation 12
- About changing the user permission level 13
- Advanced usage 13
- Operation 13
- Using quiet mode 13
- Using the dhw tank booster mode 13
- Holiday 14
- Operation 14
- Using holiday mode 14
- Configuring date time units of measurement contrast and backlight 15
- Operation 15
- Reading out information 15
- Configuring user profile and home pages 16
- Locking and unlocking buttons and functions 16
- Operation 16
- Preset values and schedules 16
- Using preset values 16
- Operation 17
- Schedules example 17
- Using and programming schedules 17
- Operation 18
- Predefined schedules dhw tank temperature 18
- Predefined schedules leaving water temperature additional 18
- Predefined schedules room temperature leaving water temperature main 18
- To set the weather dependent settings 18
- Weather dependent operation 18
- Operation 19
- Daikin altherma low temperature split 20
- Depending on the selected installer settings settings will be visible invisible 20
- Ehvh04 16su18 26cb6w 20
- Information 20
- Menu structure overview user settings 20
- Operation 20
- P449981 1 2016 6 20
- User reference guide 20
- Contact helpdesk number 6 21
- Domestic hot water control a 21
- Installer settings tables to be filled in by installer 21
- Quick wizard 21
- Setting the energy prices 21
- Space heating control 21
- To set the electricity price 21
- To set the fuel price 21
- About energy prices in case of an incentive per kwh renewable energy 22
- Energy saving tips 22
- Example 22
- To set the electricity price in case of an incentive per kwh renewable energy 22
- To set the electricity price schedule timer 22
- To set the fuel price in case of an incentive per kwh renewable energy 22
- Maintenance and service 23
- Overview maintenance and service 23
- Overview troubleshooting 23
- Symptom heat pump failure 23
- Symptom the water at the tap is too cold 23
- Symptom you are feeling too cold hot in your living room 23
- To check the error history 23
- To check the warning history 23
- To find the contact helpdesk number 23
- Troubleshooting 23
- Disposal 24
- Glossary 24
- Overview disposal 24
- Overview relocation 24
- Relocation 24
Похожие устройства
- Daikin EHVH16SU26CB6W Приложение к руководству для дополнительного оборудования
- Daikin EHVH11SU26CB6W Инструкция по монтажу
- Daikin EHVH11SU26CB6W Общие правила техники безопасности
- Daikin EHVH11SU26CB6W Руководство по эксплуатации
- Daikin EHVH11SU26CB6W Руководство по применению
- Daikin EHVH11SU26CB6W Приложение к руководству для дополнительного оборудования
- Daikin EHVH16SU26CB6W Инструкция по эксплуатации
- Daikin FWXV10AATV3 Инструкция по монтажу
- Daikin FWXV15AATV3 Инструкция по монтажу
- Daikin FWXV20AATV3 Инструкция по монтажу
- Daikin FWXM10AATV3 Инструкция по монтажу
- Daikin FWXM15AATV3 Инструкция по монтажу
- Daikin FWXM20AATV3 Инструкция по монтажу
- Daikin EHSX04P30A Руководство по применению для пользователя
- Daikin EHSX04P30A Руководство по эксплуатации
- Daikin EHSX04P30A Инструкция по монтажу
- Daikin EHSXB04P30A Руководство по применению для пользователя
- Daikin EHSXB04P30A Руководство по эксплуатации
- Daikin EHSXB04P30A Инструкция по монтажу
- Daikin EHSX08P30A Руководство по применению для пользователя