3 Operation
Operation manual
6
RHBH/X04~16CB
ROTEX HPSU low temperature Bi‑bloc
4P384967-1B – 2017.04
3.5 Advanced usage
3.5.1 About changing the user permission level
The amount of information you can read out in the menu structure
depends on your user permission level:
▪ End user (= default)
▪ Adv. end user: You can read out more information.
To set the user permission level to Advanced end user
1 Go to the main menu or any of its submenus: .
2 Press for more than 4seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set
otherwise.
To set the user permission level to End user
1 Press for more than 4 seconds.
Result: The user permission level switches to End user. The user
interface will return to the default home screen.
3.6 Schedules: Example
INFORMATION
The procedures to program other schedules are similar.
In this example:
▪ Room temperature schedule in heating mode
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1 Go to [7.3.1.1]: > User settings > Set schedules > Room
temp. > Set heating schedule.
2 Select Empty and press .
3 Program the schedule for Monday. See below for more details.
4 Copy from Monday to Tuesday, Wednesday, Thursday and
Friday. See below for more details.
5 Program the schedule for Saturday.
6 Copy from Saturday to Sunday.
7 Save the schedule and give it a name. See below for more
details.
To program the schedule for Monday
1 Use and to select Monday.
2 Press to enter the schedule for Monday.
3 Program the schedule for Monday:
▪ Use and to select an entry.
▪ Use and to change the value of an entry.
To copy from one day to another
1 Select the day from which you want to copy and press .
Example: Monday.
2 Select Copy day and press .
3 Set the days you want to copy to Yes and press . Example:
Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.
To save the schedule
1 Press , select Save schedule and press .
2 Select User defined 1, User defined 2 or User defined 3 and
press .
3 Change the name and press . (Only applicable for room
temperature schedules). Example: MyWeekSchedule
To select which schedule you currently want to use
1 Go to [5]: > Select schedules.
2 Select for which control you want to use a schedule. Example:
[5.1] Room temperature.
3 Select for which operation mode you want to use a schedule.
Example: [5.1.1] Heating .
4 Select a predefined or user‑defined schedule and press .
Содержание
- Operation manual 1
- Rotex hpsu low temperature bi bloc 1
- About the system 2
- About the system 2 2
- About this document 2
- About this document 2 2
- Comfort heating eco heating comfort cooling eco cooling 2
- Components in a typical system layout 2
- Disposal 10 2
- Energy saving tips 8 2
- Glossary 10 2
- Maintenance and service 9 2
- Operation 3 2
- Operation manual 2
- Room temperature 2
- Select scroll 2
- Table of contents 2
- Troubleshooting 9 2
- Buttons 3
- Operation 3
- Overview operation 3
- Status icons 3
- The user interface at a glance 3
- Operation 4
- Room thermostat control using the room temperature home page 4
- Setting the space operation mode 4
- Space heating cooling control 4
- To change the mode from scheduled to preset value 4
- To read out the actual and desired room temperature 4
- To set the overrule period 4
- To temporarily overrule the room temperature schedule 4
- Typical room temperature home pages 4
- Domestic hot water control 5
- Operation 5
- About changing the user permission level 6
- Advanced usage 6
- Operation 6
- Schedules example 6
- Depending on the selected installer settings settings will be visible invisible 7
- Information 7
- Menu structure overview user settings 7
- Operation 7
- Operation manual 7
- Rhbh x04 16cb rotex hpsu low temperature bi bloc 4p384967 1b 2017 4 7
- Contact helpdesk number 6 8
- Domestic hot water control a 8
- Energy saving tips 8
- Installer settings tables to be filled in by installer 8
- Quick wizard 8
- Space heating cooling control 8
- Maintenance and service 9
- Overview maintenance and service 9
- Symptom heat pump failure 9
- Symptom the water at the tap is too cold 9
- Symptom you are feeling too cold hot in your living room 9
- To find the contact helpdesk number 9
- Troubleshooting 9
- Disposal 10
- Glossary 10
- P384967 1b 12
- Subject to change and correction 12
Похожие устройства
- Daikin RHBX04CB Руководство по эксплуатации
- Daikin RHBX04CB Инструкция по монтажу
- Daikin RHBX04CB Руководство по монтажу
- Daikin RHBX08CB Технические данные
- Daikin RHBX08CB Спецификация
- Daikin RHBX08CB Инструкция по эксплуатации
- Daikin RHBX08CB Руководство по эксплуатации
- Daikin RHBX08CB Инструкция по монтажу
- Daikin RHBX08CB Руководство по монтажу
- Daikin RHBX11CB Технические данные
- Daikin RHBX11CB Спецификация
- Daikin RHBX11CB Инструкция по эксплуатации
- Daikin RHBX11CB Руководство по эксплуатации
- Daikin RHBX11CB Инструкция по монтажу
- Daikin RHBX11CB Руководство по монтажу
- Daikin RHBX16CB Технические данные
- Daikin RHBX16CB Спецификация
- Daikin RHBX16CB Инструкция по эксплуатации
- Daikin RHBX16CB Руководство по эксплуатации
- Daikin RHBX16CB Инструкция по монтажу