Daikin RDLQ05CAV3 [11/28] C 37 c
![Daikin RDLQ05CAV3 [11/28] C 37 c](/views2/1787364/page11/bgb.png)
4 Operation
User reference guide
11
RBLQ05+07CAV3 + RDLQ05+07CAV3
ROTEX HPSU low temperature monobloc
4P415098-1B – 2018.06
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.4.10 External room thermostat control - About
external room thermostat control
External room thermostat control means that you control the
following:
▪ Room temperature on the external thermostat control
▪ Leaving water temperature on the user interface (ROTEX)
To control the leaving water temperature, you can do the following:
You can… Location
Read out the desired leaving water
temperature.
Leaving water
temperature home
pages (main +
additional)
Adjust the desired leaving water
temperature.
Only change this if the desired room
temperature cannot be reached.
See also: "4.4.6Room thermostat control - Using the leaving water
temperature home pages"on page9
4.4.11 External room thermostat control - Using
external room thermostat control
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT
main).
2 Press
or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature
(additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.5 Domestic hot water control
4.5.1 About domestic hot water control
Depending on the DHW tank mode (installer setting), you use a
different domestic hot water control:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
CAUTION
The booster heater permission schedule is used to restrict
or allow booster heater operation based on a weekly
program. Advice: In order to avoid unsuccessful
disinfection function, at least allow the booster heater (by
the weekly program) for minimum 4hours starting from the
scheduled start-up of disinfection. If the booster heater is
restricted during disinfection, this function will NOT be
successful and the applicable warning AH will be
generated.
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to
program the start-up of the disinfection function at least
4 hours later than the last expected large hot water
tapping. This start-up can be set by installer settings
(disinfection function).
▪ When the Domestic hot water > Type > Scheduled only
is selected, it is recommended to program a Storage
eco 3 hours before the scheduled start-up of the
disinfection function to preheat the tank.
To determine which DHWtank mode you are using (method1)
Check the installer settings table filled in by the installer.
To determine which DHWtank mode you are using (method 2)
Prerequisite: User profile = Detailed.
1 Go to the DHWtank temperature home page (Tank).
2 Check which icons are displayed:
If… is displayed Then the DHWtank mode =…
Reheat mode
Scheduled mode
Scheduled + reheat mode
4.5.2 Reheat mode
In reheat mode (
),the DHW tank continuously heats up to the
temperature shown on the DHW tank temperature home page
(example: 50°C).
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
T
t
T
t
DHWtank temperature
t Time
INFORMATION
There is a risk of space heating (cooling) capacity
shortage/comfort problem (in case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruption will happen) when selecting [6‑0D]=0 ([A.4.1]
Domestic hot water Type=Reheat only) in case of a
domestic hot water tank without an internal booster heater.
Содержание
- Rotex hpsu low temperature monobloc 1
- User reference guide 1
- About the documentation 2
- About the system 4 2
- About this document 3 2
- Danger 2
- Danger risk of burning 2
- Danger risk of electrocution 2
- Danger risk of explosion 2
- Disposal 24 2
- Energy saving tips 22 2
- General safety precautions 2
- General safety precautions 2 2
- Glossary 24 2
- Indicates a situation that could result in burning because of extreme hot or cold temperatures 2
- Indicates a situation that could result in electrocution 2
- Indicates a situation that could result in explosion 2
- Indicates a situation that results in death or serious injury 2
- Installation manual and the installer reference guide must be performed by an authorised installer 2
- Languages are translations 2
- Maintenance and service 22 2
- Meaning of warnings and symbols 2
- Operation 4 2
- Relocation 24 2
- Setting the energy prices 21 2
- Table of contents 2
- The installation of the system and all activities described in the 2
- The original documentation is written in english all other 2
- The precautions described in this document cover very important 2
- Topics follow them carefully 2
- Troubleshooting 23 2
- User reference guide 2
- About this document 3
- For the user 3
- About the system 4
- Buttons 4
- Components in a typical system layout 4
- G b c a 4
- Operation 4
- Overview operation 4
- The user interface at a glance 4
- Basic usage 5
- Operation 5
- Status icons 5
- Turning on off controls 5
- Using home pages 5
- Using the menu structure 5
- About space heating cooling control 6
- Operation 6
- Setting the space operation mode 6
- Space heating cooling control 6
- Determining which temperature control you are using 7
- Operation 7
- Room thermostat control about room thermostat control 7
- To determine which temperature control you are using method 1 7
- To determine which temperature control you are using method 2 7
- Example temporarily overruling the schedule and changing the mode to preset value 8
- Operation 8
- Room thermostat control using the room temperature home page 8
- To change the mode from scheduled to preset value 8
- To read out the actual and desired room temperature 8
- To temporarily overrule the room temperature schedule 8
- Typical room temperature home pages 8
- C 37 c 9
- Operation 9
- Room thermostat control using the leaving water temperature home pages 9
- To adjust overrule the leaving water temperature not linked to room temperature setpoint 9
- To read out the desired leaving water temperature main additional 9
- To set the overrule period 9
- Typical leaving water temperature home pages 9
- C 37 c 10
- C 47 c 10
- Leaving water temperature control about leaving water temperature control 10
- Leaving water temperature control using leaving water temperature control according to a schedule 10
- Leaving water temperature control using leaving water temperature control not according to a schedule 10
- Operation 10
- To adjust overrule the leaving water temperature linked to room temperature setpoint 10
- To adjust the leaving water temperature additional 10
- To adjust the leaving water temperature main 10
- To set leaving water temperature preset values main 10
- 00 07 00 11
- 00 21 00 11
- About domestic hot water control 11
- C 37 c 11
- C 47 c 11
- Domestic hot water control 11
- External room thermostat control about external room thermostat control 11
- External room thermostat control using external room thermostat control 11
- Operation 11
- Reheat mode 11
- To adjust the leaving water temperature additional 11
- To adjust the leaving water temperature main 11
- 00 07 00 12
- 00 21 00 12
- C 45 c 12
- Operation 12
- Scheduled mode 12
- Scheduled reheat mode 12
- Advanced usage 13
- Operation 13
- Operation 14
- Using holiday mode 14
- Using quiet mode 14
- Holiday 15
- Operation 15
- Reading out information 15
- Configuring date time units of measurement contrast and backlight 16
- Configuring user profile and home pages 16
- Operation 16
- Preset values and schedules 16
- Using preset values 16
- Operation 17
- Schedules example 17
- Using and programming schedules 17
- Operation 18
- Predefined schedules dhw tank temperature 18
- Predefined schedules leaving water temperature additional 18
- Predefined schedules room temperature leaving water temperature main 18
- To set the weather dependent settings 18
- Weather dependent operation 18
- Operation 19
- Depending on the selected installer settings and unit type settings will be visible invisible 20
- Information 20
- Menu structure overview user settings 20
- Operation 20
- P415098 1b 2018 6 20
- Rblq05 07cav3 rdlq05 07cav3 20
- Rotex hpsu low temperature monobloc 20
- User reference guide 20
- Contact helpdesk number 6 21
- Domestic hot water control a 21
- Installer settings tables to be filled in by installer 21
- Quick wizard 21
- Setting the energy prices 21
- Space heating cooling control 21
- To set the electricity price 21
- To set the fuel price 21
- Energy saving tips 22
- Example 22
- Maintenance and service 22
- Overview maintenance and service 22
- To set the electricity price in case of an incentive per kwh renewable energy 22
- To set the electricity price schedule timer 22
- To set the fuel price in case of an incentive per kwh renewable energy 22
- Overview troubleshooting 23
- Symptom heat pump failure 23
- Symptom the water at the tap is too cold 23
- Symptom you are feeling too cold hot in your living room 23
- To check the error history 23
- To check the warning history 23
- To find the contact helpdesk number 23
- Troubleshooting 23
- Disposal 24
- Glossary 24
- Overview relocation 24
- Relocation 24
- P415098 1b 28
- Subject to change and correction 28
Похожие устройства
- Daikin RDLQ05CAV3 Инструкция по эксплуатации
- Daikin RDLQ07CAV3 Инструкция по монтажу
- Daikin RDLQ07CAV3 Руководство по применению для установщика
- Daikin RDLQ07CAV3 Общие правила техники безопасности
- Daikin RDLQ07CAV3 Руководство по применению для пользователя
- Daikin RDLQ07CAV3 Инструкция по эксплуатации
- Daikin RRLQ004CAV3 Инструкция по эксплуатации
- Daikin RRLQ004CAV3 Инструкция по монтажу
- Daikin RRLQ004CAV3 Руководство по применению для установщика
- Daikin RRLQ006CAV3 Инструкция по эксплуатации
- Daikin RRLQ006CAV3 Инструкция по монтажу
- Daikin RRLQ006CAV3 Руководство по применению для установщика
- Daikin RRLQ008CAV3 Инструкция по эксплуатации
- Daikin RRLQ008CAV3 Инструкция по монтажу
- Daikin RRLQ008CAV3 Руководство по применению для установщика
- Daikin RRLQ011CAW1 Инструкция по эксплуатации
- Daikin RRLQ011CAW1 Инструкция по монтажу
- Daikin RRLQ011CAW1 Руководство по применению для установщика
- Daikin RRLQ014CAW1 Инструкция по эксплуатации
- Daikin RRLQ014CAW1 Инструкция по монтажу