Daikin EHVH04SU23DA6V7 [22/36] Configuration

Daikin EHVH04SU23DA6V7 [22/36] Configuration
5 Configuration
Installation manual
22
EHVH04+08SU18+23DA6V7
Daikin Altherma 3 R F
4P619456-1 – 2020.03
Additionally, a storage stop can be programmed. This feature puts a
stop to tank heating even if the setpoint has NOT been reached.
Only program a storage stop when tank heating is absolutely
undesirable.
# Code Description
[5.2] [6-0A] Comfort setpoint:
30°C~[6‑0E]°C
Eco setpoint
The storage economic temperature denotes the lower desired
tank temperature. It is the desired temperature when a storage
economic action is scheduled (preferably during day).
# Code Description
[5.3] [6-0B] Eco setpoint:
30°C~min(50,[6‑0E])°C
Reheat setpoint
Desired reheat tank temperature, used:
in Schedule + reheat mode, during reheat mode: the
guaranteed minimum tank temperature is set by the Reheat
setpoint minus the reheat hysteresis. If the tank temperature
drops below this value, the tank is heated up.
during storage comfort, to prioritize the domestic hot water
preparation. When the tank temperature rises above this value,
domestic hot water preparation and space heating/cooling are
executed sequentially.
# Code Description
[5.4] [6-0C] Reheat setpoint:
30°C~min(50,[6‑0E])°C
5.3 Settings menu
You can set additional settings using the main menu screen and its
submenus. The most important settings are presented here.
5.3.1 Main zone
Thermostat type
Only applicable in external room thermostat control.
NOTICE
If an external room thermostat is used, the external room
thermostat will control the room frost protection. However,
the room frost protection is only possible if [C.2] Space
heating/cooling=On.
# Code Description
[2.A] [C–05] External room thermostat type for the
main zone:
1: 1 contact: The used external room
thermostat can only send a thermo
ON/OFF condition. There is no
separation between heating or cooling
demand.
2: 2 contacts: The used external
room thermostat can send a separate
heating/cooling thermo ON/OFF
condition.
5.3.2 Additional zone
Thermostat type
Only applicable in external room thermostat control. For more info
about the functionality, see "5.3.1Main zone"[422].
# Code Description
[3.A] [C–06] External room thermostat type for the
additional zone:
1: 1 contact
2: 2 contacts
5.3.3 Information
Dealer information
The installer can fill in his contact number here.
# Code Description
[8.3] N/A Number that users can call in case of
problems.