Daikin EHVH08SU23DA6V7 [13/36] Installation

Daikin EHVH08SU18DA6V7 [13/36] Installation
4 Installation
Installation manual
13
EHVH04+08SU18+23DA6V7
Daikin Altherma 3 R F
4P619456-1 – 2020.03
Without low voltage cables With low voltage cables
4.5.3 To connect the main power supply
1 Connect the main power supply.
In case of normal kWh rate power supply
X1M
X2M
X5M
X11YB
X1A
X11Y
X11YA
1 2 3
1 2 3
a
1 2 3
a Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
Connect X11Y to X11YB.
X1M
X2M
X5M
X11Y
X11YB
X1A
1 2 3
1 N L
N L
2 3
S1S
a b c
X11YA
51 2 3 6
9 10
a Interconnection cable (=main power supply)
b Normal kWh rate power supply
c Preferential power supply contact
2 Fix the cables with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect
X11Y to X11YB. The necessity of separate normal kWh
rate power supply to indoor unit (b) X2M/5+6 depends on
the type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
if preferential kWh rate power supply is interrupted
when active, OR
if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/9+10) as the safety
thermostat. Thus, the system can have EITHER
preferential kWh rate power supply OR a safety
thermostat.
4.5.4 To connect the backup heater power
supply
WARNING
The backup heater MUST have a dedicated power supply
and MUST be protected by the safety devices required by
the applicable legislation.
CAUTION
To guarantee the unit is completely earthed, always
connect the backup heater power supply and the earth
cable.
The backup heater capacity can vary, depending on the indoor unit
model. Make sure that the power supply is in accordance with the
backup heater capacity, as listed in the table below.
Backup
heater type
Backup
heater
capacity
Power
supply
Maximum
running
current
Z
max
*6V 2kW 1N~230V
(a)
9A
4kW 1N~230V
(a)
17A
(b)(c)
0.22Ω
6kW 1N~230V
(a)
26A
(b)(c)
0.22Ω
2kW 3~230V
(d)
5A
4kW 3~230V
(d)
10A
6kW 3~230V
(d)
15A
(a)
6V
(b)
Electrical equipment complying with EN/IEC 61000-3-12
(European/International Technical Standard setting the limits for
harmonic currents produced by equipment connected to public
low-voltage systems with input current >16A and ≤75A per
phase).
(c)
This equipment complies with EN/IEC61000‑3‑11 (European/
International Technical Standard setting the limits for voltage
changes, voltage fluctuations and flicker in public low-voltage
supply systems for equipment with rated current ≤75A) provided
that the system impedance Z
sys
is less than or equal to Z
max
at the
interface point between the user's supply and the public system. It
is the responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with
a system impedance Z
sys
less than or equal to Z
max
.
(d)
6T1
Connect the backup heater power supply as follows:

Содержание