Daikin EBHQ008BAV3 Инструкция по эксплуатации онлайн [11/20] 604811
![Daikin EBHQ008BAV3 Инструкция по эксплуатации онлайн [11/20] 604811](/views2/1787590/page11/bgb.png)
EBHQ006+008BAV3 + EKCBX/H008BAV3
Unit for air to water heat pump system
4PW64603-1A – 08.2010
Operation manual
10
Programming quiet mode, booster heating or domestic water
heating
Programming domestic water heating, booster heater or quiet mode
is carried out as follows:
1 Press the < button.
The actual mode is blinking.
2 Use the pi and pj buttons to select the mode you want
to program (quiet mode
s, booster heating m or domestic
water heating
w).
The selected mode is blinking.
3 Press the < button to confirm the selected mode.
The first programmed action is displayed.
4 Use the pi and pj buttons to consult the programmed
actions.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
5 Press the < button for 5 seconds to enter the programming
mode.
6 Use the < button to select the action number you would like to
program or to modify.
7 Use the pi and pj buttons to set the correct action time.
8 Use the ba button to select or deselect x as action.
9 Repeat steps 6 to 8 to program the other actions of the selected
mode.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
10 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
You automatically return to step 4. By pressing the pr button
several times, you return to previous steps in this procedure and
finally return to normal operation.
Consulting programmed actions
Consulting space heating or space cooling actions
Consulting space heating or space cooling is carried out as follows.
1 Use the = button to select the operation mode (cooling or
heating) you want to consult.
2 Press the < button.
The actual mode is blinking.
3 Press the < button to confirm the selected mode.
The actual day is blinking.
4 Select the day you would like to consult by means of the pi
and pj buttons.
The selected day is blinking.
5 Press the < button to confirm the selected day.
The first prog
rammed action of the selected day appears.
6 Use the pi and pj buttons to consult the other
programmed actions of that day.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
Consulting domestic water heating, booster heater or quiet
mode
Consulting domestic water heating, booster heater or quiet mode is
carried out as follows.
1 Press the < button.
The actual mode is blinking.
2 Use the pi and pj buttons to select the mode you want
to consult (quiet mode
s, booster heating m or domestic water
heating w).
The selected mode is blinking.
3 Press the < button to confirm the selected mode.
The first programmed action is displayed.
4 Use the pi and pj buttons to consult the programmed
actions.
This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the
pr button.
Consulting space heating or space cooling is done in the
same way. At the start of the consulting procedure space
heating or space cooling is selected. After that, you have to
return to the start of the consulting procedure to consult
the other operation mode.
Returning to previous steps in this procedure is done by
pressing the pr button.
Returning to previous steps in this procedure is done by
pressing the pr button.
Содержание
- Operation manual 1
- Unit for air to water heat pump system 1
- Definitions 2
- Efinitions 2
- Meaning of used terms 2
- Meaning of warnings and symbols 2
- Operation manual 2
- Afety precautions 3
- General safety precautions 3
- Introduction 3
- Ntroduction 3
- This manual 3
- This unit 3
- Features and functions 4
- Introduction 4
- Operating the digital controller 4
- Operating the unit 4
- Perating the unit 4
- Name and function of buttons and icons 5
- Description of the operation modes 6
- Setting up the controller 6
- Controller operations 7
- Programming and consulting the schedule timer 9
- Field settings 12
- Procedure 12
- Detailed description 13
- C 00 solar priority mode setting for information concerning the eksolhw solar kit refer to the installation manual of that kit 15
- C setup on ekrp1hb digital i o pcb 15
- D 03 local shift value weather dependent determines the shift value of the weather dependent set point around outdoor temperature of 0 c 15
- D local shift value weather dependent 15
- E 00 readout of the software version example 23 15
- E 01 readout of the eeprom version example 23 15
- E 02 readout of the unit model identification example 11 15
- E 03 and e 04 readouts are not permanently refreshed temperature readouts are updated after looping through the field setting first codes again only 15
- E 03 readout of the liquid refrigerant temperature 15
- E 04 readout of the inlet water temperature 15
- E unit information readout 15
- Local shift value weather dependent 15
- Notice 15
- Solar priority mode 15
- The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 weather dependent set point heating operation only on page 12 is selected 15
- Field settings table 16
- Aintenance 18
- Disposal requirements 18
- Important information regarding the refrigerant used 18
- Isposal requirements 18
- Maintenance 18
- Maintenance activities 18
- Roubleshooting 18
- Standstill 18
- Troubleshooting 18
Похожие устройства
- Daikin EBHQ008BAV3 Инструкция по монтажу
- Daikin EKCBX008BAV3 Инструкция по эксплуатации
- Daikin EKCBX008BAV3 Инструкция по монтажу
- Daikin EKCBH008BAV3 Инструкция по эксплуатации
- Daikin EKCBH008BAV3 Инструкция по монтажу
- Daikin EHSXB04P30DA Схема
- Daikin EHSXB04P30DA Руководство по монтажу
- Daikin EHSXB04P30DA Руководство по применению
- Daikin EHSXB04P30DA Руководство по эксплуатации
- Daikin EHSXB04P30DA Руководство по применению для установщика
- Daikin EHSXB04P30DA Инструкция по эксплуатации
- Daikin EHSXB04P30DA Инструкция по монтажу
- Daikin EHSXB04P50DA Схема
- Daikin EHSXB04P50DA Руководство по монтажу
- Daikin EHSXB04P50DA Руководство по применению
- Daikin EHSXB04P50DA Руководство по эксплуатации
- Daikin EHSXB04P50DA Руководство по применению для установщика
- Daikin EHSXB04P50DA Инструкция по эксплуатации
- Daikin EHSXB04P50DA Инструкция по монтажу
- Daikin EHSXB04P50DA7 Схема