Daikin EHSXB04P50DA7 [5/8] Altherma ehs x h d

Daikin EHSXB04P50DA7 [5/8] Altherma ehs x h d
X2
X1
STB
TR
L1 L2
L3
Fuse 16A
BUL1
BUT1 BUT2 BUT3
BUL2 BUL3
1
36
11
12
21
22
31
32
90°C
N
Cu
≥2,5mm²
Cu
≥2,5mm²
400 V
BUNBUN
BUNBUN
2
5
XBUH1
RTX-EHS
PE
BUN
PE
BUN
PE
74
K3 K2 K1
RCD (FI)
Power surge
category III
3N ~400V / 50Hz BU9c EKBU9C
R
D
BU9c 3x3000 W
EKBU9C 3x3000 W
R
D
X2
X1
STB
TR
BUL1
BUT1 BUT2 BUT3
BUL2 BUL3
1
36
N
BUNBUN
BUNBUN
2
5
XBUH1
RTX-EHS
PE
BUN
PE
BUN
PE
74
K3 K2 K1
230 V
Cu 10 mm²
90°C
L1 L2
L3
Fuse 16A
11
12
21
22
31
32
RCD (FI)
Power surge
category III
BU9c 3x3000 W
EKBU9C 3x3000 W
R
D
1N ~230V / 50Hz BU9c EKBU9C
R
D
BUH1 (1x 1000 W)
(1x 3000 W)
BUH3
R
EKBU1C (1x 1000 W)
EKBU3C (1x 3000 W)
D
X2
X1
BUL1
BUT1 BUT2 BUT3
BUL2 BUL3
1
36
90°C
N
Cu ≥2,5 mm²
BUNBUN
BUNBUN
2
5
XBUH1
RTX-EHS
PE
BUN
PE
BUN
PE
74
K3 K2 K1
STB
TR
L1
Fuse 16A
11
12
21
22
31
32
RCD (FI)
Power surge
category
III
1N ~230V / 50Hz 1000 W BUH1
EKBU1C
(1x 1000 W)
1N ~230V / 50Hz 3000 W BUH3
(1x 3000 W)EKBU3C
R
D
R
D
X
X
X
5/8
[BUH]
KA
.
BUH
.
07/2018
.
008.14 443 99_00
[]BUH - Backup-Heater
III
+
NNPE
PE
PE
BUN BUN
PE PE
X
I
HPSU compact Ultra
Altherma EHS(X/H)D
R
D
Cu 2,5 mm²
90°C
II
HPSU compact
HPSU monobloc compact
Altherma EHS(X/H)
R
D
Скачать