Daikin EBHQ008BBV3 [5/8] Standstill

Daikin EBHQ006BBV3 [5/8] Standstill
EBHQ006+008BBV3
Unit for air to water heat pump system
4P347826-1 – 2013.04
Operation manual
4
5.3. Standstill
6. T
ROUBLESHOOTING
The guidelines below might help to solve your problem. If you cannot
solve the problem, consult your installer.
7. D
ISPOSAL
REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with relevant local and national
legislation.
Your product is marked with this symbol. This means that
electrical and electronic products shall not be mixed with
unsorted household waste.
Do not try to dismantle the system yourself: the dismantling of the
system, treatment of the refrigerant, of oil and other parts must be
done by a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring this product is disposed off
correctly, you will help to prevent potential negative consequences for
the environment and human health. Please contact the installer or
local authority for more information.
CAUTION
During longer periods of standstill, e.g. during summer with a
heating only application or during longer periods when there
is no need of an operating unit, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic
repetitive movement of the motor in order to prevent it from
getting jammed.
CAUTION
If no glycol is in the system in case of a power supply
failure or pump operating failure, drain the system (as
suggested in the figure below).
When water is at standstill inside the system, freezing up is
very likely to happen and damaging the system in the process.
P
OSSIBLE
CAUSES
C
ORRECTIVE
ACTIONS
No readings on the remote controller
(blank display)
Check if the mains power is still
connected to your installation.
The benefit kWh rate power supply is
active (see installation manual).
One of the error codes appears Consult your local dealer.
Refer to the installation manual for a
detailed list of error codes.
The schedule timer does work but
the programmed actions are
executed at the wrong time
(e.g. 1 hour too late or too early)
Check if the clock and the day of the
week are set correctly, correct if
necessary.
The schedule timer is programmed
but does not work.
In case the
pr
icon is not displayed,
push the
pr
button to enable the
schedule timer.
Capacity shortage Consult your local dealer.
A
<A
Скачать