Daikin ERLQ007BAV39 [3/16] Installation manual
![Daikin ERLQ007BAV39 [3/16] Installation manual](/views2/1789107/page3/bg3.png)
ERLQ006~008BAV39
Outdoor unit for air to water heat pump
4PW63277-1 – 07.2010
Installation manual
1
CONTENTS Page
Safety precautions............................................................................. 1
Model................................................................................................. 3
Accessories ....................................................................................... 3
Installation guidelines ........................................................................ 3
Precautions for selecting the location ........................................................ 3
Selecting a location in cold climates .......................................................... 4
Refrigerant piping specifications................................................................ 4
Installing near a wall or obstacle................................................................ 4
Outdoor unit installation drawing................................................................ 5
Installation procedure ........................................................................ 5
Mounting the outdoor unit .......................................................................... 5
Drain work.................................................................................................. 5
Flaring the pipe end ................................................................................... 5
Connecting the refrigerant piping to the outdoor unit................................. 6
Refrigerant piping work.............................................................................. 6
Purging air and checking gas leakage....................................................... 6
Charging refrigerant................................................................................... 7
Wiring......................................................................................................... 8
Test run and final check................................................................... 10
Tr ial operation and testing........................................................................10
Items to check.......................................................................................... 10
Pump down operation...................................................................... 10
Pump down procedure............................................................................. 10
Forced cooling operation.......................................................................... 10
Maintenance and servicing.............................................................. 11
Service precautions ................................................................................. 11
Service mode operation........................................................................... 11
Disposal requirements..................................................................... 11
Unit specifications............................................................................ 11
Technical specifications ........................................................................... 11
Electrical specifications............................................................................ 11
The English text is the original instruction. Other languages are
translations of the original instructions.
SAFETY PRECAUTIONS
The precautions listed here are divided into the following four types.
They all cover very important topics, so be sure to follow them
carefully.
■ After completing installation, test the unit to check for installation
errors. Give the user adequate instructions concerning the use
and cleaning of the unit as included in the operation manual of
the indoor unit.
Danger
■ Before touching electric terminal parts, turn off power switch.
■ When service panels are removed, live parts can be easily
touched by accident.
Never leave the unit unattended during installation or servicing
when the service panel is removed.
■ Do not touch water pipes during and immediately after operation
as the pipes may be hot. Your hand may suffer burns. To avoid
injury, give the piping time to return to normal temperature or be
sure to wear proper gloves.
Warning
■
Ask your dealer or qualified personnel to carry out installation work
.
Do not install the machine by yourself.
Improper installation may result in water leakage, electric shocks
or fire.
■ Perform installation work in accordance with this installation
manual.
Improper installation may lead to water leakage, electric shocks
or fire.
■ Consult your local dealer regarding what to do in case of
refrigerant leakage. When the unit is to be installed in a small
room, it is necessary to take proper measures so that the
amount of any leaked refrigerant does not exceed the
concentration limit in the event of a leakage. Otherwise, this may
lead to an accident due to oxygen depletion.
■ Be sure to use only the specified accessories and parts for
installation work.
Failure to use the specified parts may result in water leakage,
electric shocks, fire, or the unit falling.
■ Install the unit on a foundation that can withstand its weight.
Insufficient strength may result in the fall of equipment and
causing injury.
ERLQ006BAV39
ERLQ007BAV39
ERLQ008BAV39
Outdoor unit for air to water heat pump
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
ALL ACTIVITIES DESCRIBED IN THIS MANUAL SHALL
BE CARRIED OUT BY A LICENSED TECHNICIAN.
BE SURE TO WEAR ADEQUATE PERSONEL PROTEC-
TION EQUIPMENT (PROTECTION GLOVES, SAFETY
GLASSES, ...) WHEN PERFORMING INSTALLATION,
MAINTENANCE OR SERVICE TO THE UNIT.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE
AND INFORMATION.
Meanings of DANGER, WARNING, CAUTION and NOTE symbols.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.
NOTE
Indicates situations that may result in equipment or
property-damage accidents only.
Содержание
- Installation manual 1
- Outdoor unit for air to water heat pump 1
- Daikin europe n v 2
- En60335 2 40 2
- Erlq006bav39 erlq007bav39 erlq008bav39 2
- Jean pierre beuselinck general manager ostend 1st of july 2010 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec 2
- Pw54251 7c 2
- Afety precautions 3
- Installation manual 3
- Safety precautions 3
- Caution 4
- Accessories 5
- Ccessories 5
- Installation guidelines 5
- Nstallation guidelines 5
- Precautions for selecting the location 5
- Installing near a wall or obstacle 6
- Refrigerant piping specifications 6
- Refrigerant piping specifications 6
- Selecting a location in cold climates 6
- Wall facing one side unit mm 6
- Walls facing three sides unit mm 6
- Walls facing two sides unit mm 6
- Drain work 7
- Flaring the pipe end 7
- Installation procedure 7
- Mounting the outdoor unit 7
- Nstallation procedure 7
- Outdoor unit installation drawing 7
- Connecting the refrigerant piping to the outdoor unit 8
- Pipe handling guidelines 8
- Purging air and checking gas leakage 8
- Refrigerant piping work 8
- Selection of copper and heat insulation materials 8
- Charging refrigerant 9
- Important information regarding the refrigerant used 9
- Re charging 9
- Charging additional refrigerant 10
- Precautions when adding r410a 10
- Wiring 10
- Notes to observe 11
- Procedure 11
- Est run and final check 12
- Forced cooling operation 12
- Items to check 12
- Pump down operation 12
- Pump down procedure 12
- Test run and final check 12
- Trial operation and testing 12
- Ump down operation 12
- Aintenance and servicing 13
- Disposal requirements 13
- Electrical specifications 13
- Electrical specifications 13
- Isposal requirements 13
- Maintenance and servicing 13
- Nit specifications 13
- Service mode operation 13
- Service precautions 13
- Technical specifications 13
- Technical specifications 13
- Unit specifications 13
Похожие устройства
- Daikin ERLQ008BAV39 Инструкция по монтажу
- Daikin ERGA04DAV3 Инструкция по монтажу
- Daikin ERGA04DAV3 Справочное руководство для монтажника
- Daikin ERGA04DAV3 Руководство по применению для установщика
- Daikin ERGA06DAV3 Инструкция по монтажу
- Daikin ERGA06DAV3 Справочное руководство для монтажника
- Daikin ERGA06DAV3 Руководство по применению для установщика
- Daikin ERGA08DAV3 Инструкция по монтажу
- Daikin ERGA08DAV3 Справочное руководство для монтажника
- Daikin ERGA08DAV3 Руководство по применению для установщика
- Daikin ERGA04DAV3A Инструкция по монтажу
- Daikin ERGA04DAV3A Справочное руководство для монтажника
- Daikin ERGA04DAV3A Руководство по применению для установщика
- Daikin ERGA06DAV3A Инструкция по монтажу
- Daikin ERGA06DAV3A Справочное руководство для монтажника
- Daikin ERGA06DAV3A Руководство по применению для установщика
- Daikin ERGA08DAV3A Инструкция по монтажу
- Daikin ERGA08DAV3A Справочное руководство для монтажника
- Daikin ERGA08DAV3A Руководство по применению для установщика
- Daikin EKEPRHLT3HX Инструкция по монтажу