4.4
In the event of a malfunction, the display shows an alarm code.
Thedevice will nonetheless continue to perform certain functions
(see OPERATION column).
Alarms display
Alarm displayed Cause Operation
E1
Room temperature probe (RT)
failure.
It is possible to normally activate the Cooling, Dehumidification
and Heating modes.
E2
Internal battery probe IPT failure
It is possible to normally activate the Cooling, Dehumidification
and Heating modes.
E5 Indoor fan motor failure You cannot activate any operating mode.
E7
Lack of communication with
the display *
You cannot activate any operating mode.
CP Presence contact CP open
The unit is enabled only if the contact is closed. Check the
connection of the terminals.
flashing Incorrect water temperature In heating mode, the water temperature is below 30 °C
flashing Incorrect water temperature In cooling mode, the water temperature is above 20 °C
Key/Display
Operation
Setting the Timer function
• The device’s operating logic allows the user to freely programme when it is to switch on or off.
• While the cooler-radiator is on, you can programme it to switch off by pressing the Timer key and then setting the
number of hours (from 1 to 24) after which the device is to switch to stand-by.
• When the cooler-radiator is off, you can programme it to switch on by pressing the Timer key and then setting the
number of hours (from 1 to 24) after which the device is to switch on.
• Next, press the enter key.
Touch-screen display keylock
• To lock the keys, hold the Timer symbol on the touch-screen display pressed for 3 seconds. The keylock will
prevent the user from enabling or disabling any function on the display. The stand-by symbol flashes intermittently
every second.
• To turn off the key-lock, press the Timer symbol again for 3 seconds on the touch-screen display.
Any selection from the remote control will deactivate the key-lock!
Troubleshooting
If you lose the remote control, the batteries run out or the remote
stops working, you can be operate the device with the keys on the
touch-screen display on-board the machine.
Operating the unit if the remote control is not available
For the user it is important to distinguish any malfunction or
performance levels that differ from the system’s standard
operating values (see technical specifications). The most
common problems can be easily solved by the user by
performing certain simple tasks (see the Troubleshooting
paragraph), while some system alarms require that you
contact the Technical Customer Service.
Please keep in mind that any attempt by unauthorised staff to
repair the device automatically voids any form of warranty.
Содержание
- Installation manual p.1
- Daikin altherma aesthetic feet kit p.1
- Installation and user manual p.1
- Daikin altherma heat pump convector p.1
- We want to thank you for choosing one of our products p.2
- We are confident that you will be happy with your selection because it represents the state of the art in the technology of home climate control p.2
- Symbols p.2
- Safety pictograms p.2
- Editorial pictograms p.2
- Daikin europe n v p.2
- Compliance p.2
- By following the suggestions contained in this manual the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs p.2
- General table of contents p.3
- General p.3
- Control panel installation and connection 21 p.3
- Instructions for use with touch screen and remote control 26 p.3
- Instructions for use with remote panel ekwhctrl1 30 p.3
- Installation 9 p.3
- Troubleshooting 39 p.4
- Routine maintenance 36 p.4
- General warnings p.5
- General p.5
- Essential safety rules p.6
- Technical specifications p.7
- Product range p.7
- Filomuro overall dimensions p.8
- Dimensions and weight for transportation p.8
- Installation space p.9
- Unit placement p.9
- Installation procedure p.9
- Installation p.9
- Opening the unit p.10
- Wall installation p.12
- Installation template p.14
- Hydraulic connections p.16
- Connection to the 2 way valve unit with thermoelectric motor ekt2vk0 p.17
- Connection to the 3 way diverter valve unit with thermoelectric motor ekt3vk0 p.17
- Condensate drain pipe assembly p.18
- Condensate drain p.18
- Filling system p.19
- Evacuating the air when filling the system p.19
- Wiring p.20
- Cp presence contact input connection p.21
- Control panel installation and connection p.21
- Connection diagram p.21
- Board connections with touchpad and remote control p.21
- Connection diagram p.22
- Connection for remote control panel p.22
- Fitting the wall mounted remote control panel ekwhctrl1 p.23
- Spring clamps ab and cp connection p.24
- Cp presence contact input connection p.24
- Ekwhctrl1 connections p.25
- You can also select the various functions by pressing on the symbols p.26
- Warnings p.26
- Normally the display shows the operating status see the functional description chapter and any alarms see the alarms display paragraph p.26
- Management of the unit with the touch screen and remote control p.26
- Instructions for use with touch screen and remote control p.26
- Operation p.27
- Main switch on and operation p.27
- Key display p.27
- Inserting the battery p.27
- Functional description p.27
- Airflow direction control p.28
- Ventilation only mode p.28
- Power on off p.28
- Operation p.28
- Night comfort key p.28
- Key display p.28
- Heating only mode p.28
- Fan speed control p.28
- Cooling only mode p.28
- Troubleshooting p.29
- Touch screen display keylock p.29
- Setting the timer function p.29
- Operation p.29
- Operating the unit if the remote control is not available p.29
- Key display p.29
- Alarms display p.29
- Display p.30
- Wall mounted control panel with room probe p.30
- Instructions for use with remote panel ekwhctrl1 p.30
- Keys function p.31
- Heating cooling operating mode set up p.31
- General start up p.31
- Activation p.31
- Temperature selection p.32
- Stand by p.32
- Silent operation p.32
- Night function p.32
- Automatic operation p.32
- Room temperature probe offset adjustment p.33
- Operation at maximum ventilation speed p.33
- Minimum brightness reduction p.33
- Key locking p.33
- Deactivation p.33
- Long term shut down p.34
- Led signals ref a p.34
- Error signals p.34
- Electronic control board p.34
- Error reporting p.35
- Routine maintenance p.36
- Maintenance p.36
- External cleaning p.36
- Extraction of filter cells p.37
- Cleaning the air suction filter p.37
- Suggestions for power saving p.38
- Filter media cleaning p.38
- Troubleshooting table p.39
- Troubleshooting p.39
Похожие устройства
-
Daikin RFWXV20AVEBИнструкция по монтажу -
Daikin RFWXV20AVEBИнструкция по эксплуатации -
Daikin RFWXV20AVEBРуководство по монтажу -
Daikin RFWXV20AVEBРуководство по применению -
Daikin RFWXV15AVEBИнструкция по монтажу -
Daikin RFWXV15AVEBИнструкция по эксплуатации -
Daikin RFWXV15AVEBРуководство по монтажу -
Daikin RFWXV15AVEBРуководство по применению -
Daikin FWXT20AATV3CLИнструкция по эксплуатации -
Daikin FWXT15AATV3CLИнструкция по эксплуатации -
Daikin FWXT20AATV3CИнструкция по эксплуатации -
Daikin FWXT15AATV3CИнструкция по эксплуатации
Узнайте, как управлять устройством для климат-контроля и устранять неполадки. Получите советы по программированию таймера и блокировке экрана.