Daikin EKOMB33AAV1H [52/432] Technical specifications

Daikin EKOMB28AAV1H [52/432] Technical specifications
Daikin Europe NV 52
10 TECHNICAL SPECIFICATIONS
Unit category
B23; B33; C13; C33; C43; C53; C63; C83:C93
Initial gas pressure
G20: 20 mbar, G31: 28-50 mbar
Suitable for gas
IT, GR, PT : II2H3P
FR : II2Esi3P
BE : I2E(S)
PL : II2E3P
Technical data
EKOMB*AAV1H
22
28
33
Nom. load upper value
kW
6,2 24,6
7,9 31,1
8.0 36.3
Nom. load lower value
kW
5,6 22,1
7,1 28,0
7.2 32.7
Nom. input*
kW
6,1 21,0
6,6 26,2
7.9 31.5
Domestic water threshold
l/min
2
Domestic water quantity 60°C
l/min
6
7.5
9
Domestic water quantity 40°C (mixed)
l/min
10
12.5
15
Domestic water temperature
°C
60
Effective unit wait time**
sec
<1
Domestic water side pressure difference
kPa
See par. 5.2
CH
Nom. load upper value*
kW
6.2 20.8
7.9 26.3
8.0 30.3
Nom. load lower value*
kW
5.6 18.7
7.1 23.7
7.2 27.3
Nom. input at 80/60°C*
kW
5.4 17.8
6.9 22.8
7.1 26.3
Nom. input at 50/30°C*
kW
5.9 18.5
7.6 23.4
7.8 27.1
Max. CH water pressure
bar
3
Max. CH water temperature
°C
90
Other data
Gas consumption (G20)
m
3
/h
0.58 2.29
0.74 2.91
0.75 3.39
Gas consumption (G31)
m
3
/h
0.21 0.94
0.29 1.19
0.30 1.29
Pressure loss unit (CH)
mH2O
See par. 7.4
Max. Flue gas temperature DHW
°C
90
90
90
Mass.flow flue gas (max)
g/s
11,4
14,0
15,3
Available fan pressure
Pa
75
75
75
NOx class
6
6
6
NOx
mg/kWh
30
37
56
P1, at 30% of Rated input (30/37)
kW
7,5
9,4
32,0
P4, Rated output (80/60)
kW
17,8
22,8
26,3
ɳ 1, Efficiency at P1
%
107,1
107,9
108,5
ɳ 4, Efficiency at P4
%
95,4
96,2
96,5
Electrical data
Mains voltage
V
230
230
230
Safety class
IP
IP44
(B23, B33 = IP20)
IP44
(B23, B33 = IP20)
IP44
(B23, B33 = IP20)
Absorbed power: full load
W
80
80
80
Absorbed power: standby
W
2
2
2
Installation measurements and weight
Height
mm
590
650
710
Width
mm
450
Depth
mm
240
Weight
kg
30
33
36
* The maximum CH power is set in the factory. For the set value see the parameter list