Daikin EKHTSU260AB [291/292] Drawings flow charts

Daikin EKHTSU260AB [291/292] Drawings flow charts
ESIE09-08B
Drawings & Flow Charts iii
Drawings & Flow Charts
A
abnormal discharge pipe temperature .........164, 165
actuation of high pressure switch .................147, 149
actuation of low pressure sensor .................152, 154
C
check for causes of drop in low pressure .............210
check for causes of rise in high pressure .............209
check for fan motor connector ..............................211
check operation ......................................................76
check work prior to turn power supply on ...............70
communication error between outdoor and indoor
unit ................................................................206
compressor motor lock .........................................157
contents of control modes
how to select operation mode ........................106
F
failure of transmission (between indoor unit pc
board and control pc board) ..........................138
field setting from outdoor unit ...............................106
freeze prevention ...................................................62
functional parts layout ............................................11
H
high pressure protection control .............................54
high voltage of capacitor in main inverter
circuit .....................................................191, 192
I
inverter compressor abnormal .....................182, 183
inverter compressor motor lock ............................156
inverter current abnormal .............................184, 185
inverter protection control .......................................59
inverter start up error ....................................186, 187
L
leaving water thermistor error r5t .........................143
low pressure drop due to refrigerant shortage or
electronic expansion valve failure .................194
M
malfunction of capacity determination device ......137
malfunction of discharge pipe thermistor (r2t) ......167
malfunction of discharge pipe thermistor (r6t) ......168
malfunction of high pressure sensor ............174, 175
malfunction of inverter radiating fin temperature
rise ........................................................180, 181
malfunction of low pressure sensor ..............176, 177
malfunction of moving part of electronic
expansion valve (k1e) ...................................134
malfunction of moving part of electronic
expansion valve (y1e, y3e) ...................160, 162
malfunction of outdoor unit fan motor ...................158
malfunction of system, refrigerant system address
undefined .....................................................
208
m
alfunction of tank thermistor (r3t) ...................... 141
malfunction of thermistor (r1t) for outdoor air ...... 166
malfunction of thermistor (r3t, r5t) for suction
pipe 1, 2 ....................................................... 169
malfunction of thermistor (r3t) liquid thermistor
r-410a ........................................................... 140
malfunction of thermistor (r4t) ............................. 173
malfunction of thermistor (r6t) ............................. 171
malfunction of thermistor (r7t) for outdoor unit
liquid pipe ..................................................... 172
malfunction of thermistor (r7t) for suction
pipe 1, 2 ....................................................... 170
malfunction of thermostat sensor in remote
control .......................................................... 144
malfunction of transmission between indoor units
and outdoor units ................................. 200, 202
malfunction of transmission between inverter and
control pc board ................... 188, 189, 190, 193
malfunction of transmission between main and
sub remote controls ...................................... 205
malfunction of transmission between outdoor
units .............................................................. 204
malfunction of transmission between remote
control and indoor unit .................................. 203
method of replacing the inverter’s power
transistors modules ...................................... 243
O
operation mode ..................................................... 46
operation of the remote controller’s inspection / test
operation button ........................................... 123
outdoor unit pc board layout .................................. 78
P
pc board defect ................................... 132, 145, 146
pcb layout for ekhbrd 011/014/016 aav1 ............... 30
piping diagrams ................................................... 214
power supply insuf
f
icient or instantaneous
failure ................................................... 196, 198
pressure sensor .................................................. 242
pump error (m1p) or other water system error .... 133
R
refrigerant circuit ..................................................... 8
remote control service mode ............................... 124
remote controller self-diagnosis function ............. 126
return water thermistor ........................................ 142