3 Operation
Operation manual
6
EHYHBH05AFV3* + EHYHBH/X08AFV3*
Daikin Altherma hybrid heat pump
4P349588-1F – 2020.10
t Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity
shortage and comfort problem is significant. In case of
frequent reheat operation, space heating/cooling function
is regularly interrupted.
Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because the space heating demand is
lower.
Example:
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
5
T
t
T
t
Domestic hot water tank temperature
t Time
Scheduled + reheat mode
In scheduled + reheat mode ( ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
t
T
t
60°C
00:00 07:00
50°C
45°C
15°C
14:00 21:00
35°C
1
2
4
5
3
T
t
DHWtank temperature
t Time
60°C Storage comfort
50°C Storage eco
45°C Reheat
35°C Reheat tank temperature–hysteresis value
Using the DHWtank temperature home page
Typical DHWtank temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. The examples in the illustrations
below are in DHWtank mode = Scheduled.
User profile = Basic User profile = Detailed
15:20
60°C
Storage comfort
Tank
Mon
15:20
60°C
00:00
Mon
Tue
Tank
Storage comfort
To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)
1 Go to [7.4.3.3]: > User settings > Preset values > Tank
temperature > Reheat.
Result: You can read out the desired reheat temperature.
2 Press or to adjust.
To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or scheduled + reheat mode)
1 Go to the DHWtank temperature home page (Tank).
Result:
60°C
is displayed.
2 Press or to overrule.
Note: If the desired temperature is weather dependent, you cannot
change it on the home page.
Using the DHWtank booster mode
To activate the DHWtank booster mode (user profile = Basic)
1 Go to the DHWtank temperature home page (Tank).
2 Press for more than 5seconds.
To activate the DHWtank booster mode (user profile = Detailed)
1 Go to the DHWtank temperature home page (Tank).
2 Press to select .
3.5 Schedules: Example
INFORMATION
The procedures to program other schedules are similar.
In this example:
Room temperature schedule in heating mode
Monday = Tuesday = Wednesday = Thursday = Friday
Saturday = Sunday
To program the schedule
1 Go to [7.3.1.1]: > User settings > Set schedules > Room
temp. > Set heating schedule.
2 Select Empty and press .
3 Program the schedule for Monday. See below for more details.
4 Copy from Monday to Tuesday, Wednesday, Thursday and
Friday. See below for more details.
5 Program the schedule for Saturday.
6 Copy from Saturday to Sunday.
7 Save the schedule and give it a name. See below for more
details.
To program the schedule for Monday
1 Use and to select Monday.
2 Press to enter the schedule for Monday.
3 Program the schedule for Monday:
Use and to select an entry.
Use and to change the value of an entry.
To copy from one day to another
1 Select the day from which you want to copy and press .
Example: Monday.
2 Select Copy day and press .
3 Set the days you want to copy to Yes and press . Example:
Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.