Instructions Manual
Motorpumps
Cod. doc. M.I. EP-18
Issue 0
Page 30 of 31
This Manual remains the property of the Manufacturer; it may not be reproduced or copied, even partially.
Water in the oil
Worn plunger – oil shaft seal ring. If the oil
is milky (emulsified), but the level does
not increase in the crankcase, there is
condensation
Replace the ring seal
Change the oil more frequently
Water leaking between the
crankcase and the manifold
housing
Worn seal pack
Replace seal pack
Worn piston
Replace piston
Worn piston bolt seal
Replace seal
Oil leaking between the crankcase
and the manifold housing
Worn piston - shaft oil seal
Replace the seal
Short bearing life
Pump-motor coupling problems
Check the status of the keys, flexible coupling or
pulley
The oil has not been changed regularly
Change the oil as instructed in the maintenance
manual for the pump
Excessive pressure of the pumped water
Check the pressure
Motor very noisy
Worn motor bearings
Change the bearings
8 DISMANTLING AND DISPOSAL
Contact the Manufacturer for information and instructions before dismantling the pump in order to move
it or for its disposal.
Only qualified personnel are allowed to dispose of the pump in accordance with current legislation on safety at work.
Any parts removed must be separated for recycling according to the type of materials they are made of. Do not dump hazardous
waste, including seals and lubricants, into the environment.
Any non-ferrous parts must be disposed of by an authorised company. Any parts made of iron can be recycled or sold.
The manufacturer must be notified if the machine is decommissioned or sold.
The packing materials can be recycled. Do not throw the packing materials away with normal household waste, but send them for
recycling.
The pump contains important raw materials that can be recycled and so they should be sent for recycling to make sure they will be
used again.
Do not throw oil away down the drain.
In Italy, electrical/ electronic parts must be delivered to an authority that deals with disposal in accordance with RAEE specifications.
Dispose of the pump/motorpump properly at an authorised waste disposal centre.
9 SPARE PARTS
Always use original spare parts (Attachment II).
Содержание
120- Instructions manual
- Leuco s p a
- Instructions manual
- General information
- Aim and contents
- Structure of the manual
- Motorpumps
- Intended recipients definitions
- Storage
- Instructions manual
- Service centres
- Leuco s p a via colletta 20 42124 reggio emilia re italy
- Motorpumps
- Manufacturer
- Ec mark and certification declaration of incorporation
- Symbols used in the manual
- Instructions manual
- Motorpumps
- Guarantee
- Instructions manual
- Motorpumps
- General description
- Main parts
- Instructions manual
- Motorpumps
- Technical characteristics
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Local conditions
- Motorpumps
- Instructions manual
- Instructions manual
- Pressurised liquids
- Motorpumps
- High temperatures
- General safety instructions
- Vibration
- Stability
- Safety
- Instructions manual
- Residual risks
- Motorpumps
- Working safely
- Instructions manual
- Personal protective equipment
- Motorpumps
- Safety when using the pump
- Safety when using high pressure circuits
- Packing unpacking and transport
- Motorpumps
- Instructions manual
- Safety during lifting and handling
- Rules of conduct regarding the use of high pressure lance
- Motorpumps
- Instructions manual
- This manual remains the property of the manufacturer it may not be reproduced or copied even partially
- Safety during maintenance
- Page 15 of 31
- Issue 0
- Follow the instructions below whenever carrying out any maintenance or repair work depressurise the water system and disconnect the pump from any power source before starting any maintenance or repair work
- Failure to comply with these instructions may lead to situations of extreme danger
- Each motorpump is packed so that it is protected from stress and impact and will not be damaged during transport based on the amount of goods to be shipped and the final place of destination the packed pumps can be placed on a pallet to facilitate lifting and handling when unpacking check the parts are intact and they are the correct amount if any parts are damaged or missing contact your dealer or the manufacturer for instructions dispose of packing materials correctly according to legal obligations different means of transport may be used to ship hawk motorpumps road rail sea or air depending on their final destination secure the packs to the vehicle properly during transport to prevent movement
- Cod doc m i ep 18
- As evidenced by the dimensional specifications the product described in this document requires special handling with suitable as evidenced by the dimensional specifications the product described in this document requires special handling with suitable lifting devices for example belts and hoists
- Instructions manual
- Products used
- Product labels
- Motorpumps
- First aid
- What the first aider does
- The emergency call
- Other signs on the equipment
- Motorpumps
- Instructions manual
- Motorpumps
- Intended use
- Injuries
- Instructions manual
- Improper uses
- Bleeding
- Motorpumps
- Installation and assembly
- Instructions manual
- Responsibilities of the customer user
- Motorpumps
- Instructions manual
- Pre commissioning instructions
- Motorpumps
- Long periods of inactivity
- Instructions manual
- Operation
- Motorpumps
- Instructions manual
- The table below is an example of how to choose the nozzle correctly based on the pump s specifications maximum pressure and flow rate factor the table gives an example pump with pmax 100 bar and flow rate 15 l min
- Pag 24 di 31
- Nozzle table
- Motorpumps
- Instructions manual
- Cod doc m i ep 18
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Instructions manual
- General maintenance
- Motorpumps
- Maintenance
- Motorpumps
- Instructions manual
- Instructions manual
- Trouble shooting
- Troubleshooting
- Motorpumps
- Spare parts
- Dismantling and disposal
- Motorpumps
- Instructions manual
- Attachments
Похожие устройства
-
HAWK AQUA 1320R (1450 об/мин)Деталировка -
HAWK AQUA 1320R (1450 об/мин)Инструкция по эксплуатации -
HAWK XLT 2520IRДеталировка -
HAWK XLT 2520IRИнструкция по эксплуатации -
HAWK HD 1115RДеталировка -
HAWK HD 1115RИнструкция по эксплуатации -
HAWK XXT7015IR (1450 об/мин)Деталировка -
HAWK XXT7015IR (1450 об/мин)Инструкция по эксплуатации -
HAWK XXT5520IR (1450 об/мин)Деталировка -
HAWK XXT5520IR (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1320RN (1450 об/мин)Деталировка -
HAWK AQUA 1320RN (1450 об/мин)Инструкция по эксплуатации
Узнайте, как правильно обслуживать насосы, заменять детали и утилизировать оборудование. Следуйте рекомендациям для безопасной эксплуатации и переработки.