Instructions Manual
Motorpumps
Cod. doc. M.I. EP-18
Issue 0
Page 15 of 31
This Manual remains the property of the Manufacturer; it may not be reproduced or copied, even partially.
- Check that the lifting
devices and relevant
accessories are of a
suitable capacity.
- Position the belts on
the motorpump so
that the centre of
gravity is centre of
the pump.
- Ensure that the ends
of the belts inserted
in the block allow the
safety hook to close
correctly. Otherwise,
use smaller belts
(ensure that they are
- With one hand, use
the controls on the
pushbutton panel.
lifting the
motorpump a little at
first to ensure that it
is stable.
- Aid the movement of
the motorpump with
the other hand. Use
slow movements and
ensure that no
persons not involved
in the operation are
in the area.
- Do not create
- Move towards the
bench or the are
where the
motorpump is to be
positioned, ensuring
that it is clear, stable
and flat.
- Slowly rest the
motorpump on the
bench.
- Once the
motorpump
is securely on
the support
surface free
the belts and
more the
lifting device
away.
- The lifting
and
movement
Each motorpump is packed so that it is protected from stress and impact, and will not be damaged during transport.
Based on the amount of goods to be shipped and the final place of destination, the packed pumps can be placed on a pallet to
facilitate lifting and handling.
When unpacking, check the parts are intact and they are the correct amount. If any parts are damaged or missing, contact your
dealer or the Manufacturer for instructions.
Dispose of packing materials correctly according to legal obligations.
Different means of transport may be used to ship Hawk motorpumps (road, rail, sea or air) depending on their final destination.
Secure the packs to the vehicle properly during transport to prevent movement.
Failure to comply with these instructions may lead to situations of extreme danger.
As evidenced by the dimensional specifications, the product described in this document requires special handling with suitable
lifting devices, for example belts and hoists:
3.6 Safety during Maintenance
Follow the instructions below whenever carrying out any maintenance or repair work:
Depressurise the water system and disconnect the pump from any power source before starting any
maintenance or repair work.
Содержание
120- Instructions manual
- Leuco s p a
- Instructions manual
- General information
- Aim and contents
- Structure of the manual
- Motorpumps
- Intended recipients definitions
- Storage
- Instructions manual
- Service centres
- Leuco s p a via colletta 20 42124 reggio emilia re italy
- Motorpumps
- Manufacturer
- Ec mark and certification declaration of incorporation
- Symbols used in the manual
- Instructions manual
- Motorpumps
- Guarantee
- Instructions manual
- Motorpumps
- General description
- Main parts
- Instructions manual
- Motorpumps
- Technical characteristics
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Local conditions
- Motorpumps
- Instructions manual
- Instructions manual
- Pressurised liquids
- Motorpumps
- High temperatures
- General safety instructions
- Vibration
- Stability
- Safety
- Instructions manual
- Residual risks
- Motorpumps
- Working safely
- Instructions manual
- Personal protective equipment
- Motorpumps
- Safety when using the pump
- Safety when using high pressure circuits
- Packing unpacking and transport
- Motorpumps
- Instructions manual
- Safety during lifting and handling
- Rules of conduct regarding the use of high pressure lance
- Motorpumps
- Instructions manual
- This manual remains the property of the manufacturer it may not be reproduced or copied even partially
- Safety during maintenance
- Page 15 of 31
- Issue 0
- Follow the instructions below whenever carrying out any maintenance or repair work depressurise the water system and disconnect the pump from any power source before starting any maintenance or repair work
- Failure to comply with these instructions may lead to situations of extreme danger
- Each motorpump is packed so that it is protected from stress and impact and will not be damaged during transport based on the amount of goods to be shipped and the final place of destination the packed pumps can be placed on a pallet to facilitate lifting and handling when unpacking check the parts are intact and they are the correct amount if any parts are damaged or missing contact your dealer or the manufacturer for instructions dispose of packing materials correctly according to legal obligations different means of transport may be used to ship hawk motorpumps road rail sea or air depending on their final destination secure the packs to the vehicle properly during transport to prevent movement
- Cod doc m i ep 18
- As evidenced by the dimensional specifications the product described in this document requires special handling with suitable as evidenced by the dimensional specifications the product described in this document requires special handling with suitable lifting devices for example belts and hoists
- Instructions manual
- Products used
- Product labels
- Motorpumps
- First aid
- What the first aider does
- The emergency call
- Other signs on the equipment
- Motorpumps
- Instructions manual
- Motorpumps
- Intended use
- Injuries
- Instructions manual
- Improper uses
- Bleeding
- Motorpumps
- Installation and assembly
- Instructions manual
- Responsibilities of the customer user
- Motorpumps
- Instructions manual
- Pre commissioning instructions
- Motorpumps
- Long periods of inactivity
- Instructions manual
- Operation
- Motorpumps
- Instructions manual
- The table below is an example of how to choose the nozzle correctly based on the pump s specifications maximum pressure and flow rate factor the table gives an example pump with pmax 100 bar and flow rate 15 l min
- Pag 24 di 31
- Nozzle table
- Motorpumps
- Instructions manual
- Cod doc m i ep 18
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Instructions manual
- General maintenance
- Motorpumps
- Maintenance
- Motorpumps
- Instructions manual
- Instructions manual
- Trouble shooting
- Troubleshooting
- Motorpumps
- Spare parts
- Dismantling and disposal
- Motorpumps
- Instructions manual
- Attachments
Похожие устройства
-
HAWK AQUA 1320R (1450 об/мин)Деталировка -
HAWK AQUA 1320R (1450 об/мин)Инструкция по эксплуатации -
HAWK XLT 2520IRДеталировка -
HAWK XLT 2520IRИнструкция по эксплуатации -
HAWK HD 1115RДеталировка -
HAWK HD 1115RИнструкция по эксплуатации -
HAWK XXT7015IR (1450 об/мин)Деталировка -
HAWK XXT7015IR (1450 об/мин)Инструкция по эксплуатации -
HAWK XXT5520IR (1450 об/мин)Деталировка -
HAWK XXT5520IR (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1320RN (1450 об/мин)Деталировка -
HAWK AQUA 1520RN (1450 об/мин)Деталировка
Узнайте, как правильно использовать и обслуживать насосы. Следуйте инструкциям по безопасной эксплуатации и уходу за оборудованием для предотвращения аварий.