HPP EF 75/280 (850 об/мин) [18/108] Storage

HPP EF 111/210 (1000 об/мин) [18/108] Storage
18
EF 139/150 EF 154/150 EF 165/120 EF 183/120
MECHANICAL CONNECTION
Max power input (kW - HP) 41,0-55,0 45,0-62,0 39,0-53,0 43,0-59,0
Min rotation speed (RPM) 400
Max rotation speed (RPM) 900 1000 900 1000
PUMP OIL
(1)
GAZPROM-NEFT G-Truck GL-5 80W-90
Quantity in weight (kg - lb) 4,0-8,82
Quantity in volume (l - USgal) 4,44-1,17
HYDRAULIC CONNECTION
Max water temperature
(2)
(°C - °F) 40-104
Min water temperature (°C - °F) 5-41
Max water pressure
(3)
(bar - psi) 4-58
Min water pressure
(3)
(bar - psi) 2-29
Min water ow rate 1,3 x max ow rate
PERFORMANCE - WEIGHT
Max ow rate (l/min - USgpm) 139-36,6 154-40,7 165-43,6 183-48,4
Max pressure (bar - psi) 150-2176 120 - 1740
Max level of sound pressure - uncertainty 79 dB(A)-1 dB(A)
Pump weight (dry) (kg - lb) 90-198,4
EFR 139/150 EFR 154/150 EFR 165/120 EFR 183/120
GEARBOX
Max input speed R=1,52:1 (RPM) -- 1500 -- 1500
Min input speed R=1,52:1 (RPM) -- 608 -- 608
Max input speed R=1,81:1 (RPM) -- 1800 -- 1800
Min input speed R=1,81:1 (RPM) -- 724 -- 724
Max input speed R=2,18:1 (RPM) -- 2200 -- 2200
Min input speed R=2,18:1 (RPM) -- 872 -- 872
Pump weight with gearbox (dry) (kg - lb) 105-231,5
PUMP OIL WITH GEARBOX
(1)
GAZPROM-NEFT G-Truck GL-5 80W-90
Quantity in weight (kg - lb)
: 5,4-11,90 [45°: 5,1-11,24] [90°: 5,0-11,02]
(4)
Quantity in volume (l - USgal) : 6,00-1,59 [45°: 5,67-1,50] [90°: 5,56-1,47]
(4)
(1)
Corresponding oils:
ESSO - Gear Oil GX 80W-90;
SHELL - Spirax S2 A 80W-90;
TOTAL - Transmission TM 80W-90;
ENI - Agip Rotra MP 80W-90.
(2)
Operation at temperatures above 40 °C/104 °F (but in any case within the limit of 60 °C/140 °F) is only possible if the machine integrating
the pump complies with the plant engineering requisites shown in the paragraph “Operation at a temperature above max value”. In
any case, refer to the manual of the machine integrating the pump
(3)
Value to be read at pump suction connection.
(4)
Refer to Fig. 4.
Specifications and data are approximate. The Manufacturer reserves the right to make all modifications
to the machine deemed necessary
STORAGE
CAUTION
Never store the pump in the open and, in general, in damp premises. Protect the pump against dirt and dust.
For storage periods longer than two months:
- protect the coupling surfaces and the outside machined parts using an anti-oxidising product.

Содержание

Скачать